1501971 ADAPTER Caterpillar parts
Rating:
Alternative (cross code) number:
CA1501971
150-1971
1501971
CA1501971
150-1971
1501971
Weight: 0.18 pounds 0 kg.
Information:
JIC DASH SIZE
8
JIC THREAD SIZE
.75-16
ORIFICE SIZE
0
OVERALL LENGTH
40.6
mm
STOR DASH SIZE
10
STOR SEAL PART NUMBER
2M9780
STOR THREAD SIZE
.88-14
Information:
Illustration 1 g00801447
Schematic of the solenoid valve (charge)This diagnostic code is associated with the solenoid valve (charge). The FMI 05 means that the ECM has determined that the current of the solenoid is below normal. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0392 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code of CID 0392 FMI 05 will be logged in the internal memory of the All Wheel Drive ECM.The AWD feature will be disabled.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 2 (wire 989-YL) to contact 1 (wire 912-GY).
Observe the status of the CID 0392 FMI 05.Expected Result:The CID 0392 FMI 05 remains active. The FMI has not changed and the "05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem. Stop.Test Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J1-12 (wire 989-YL) to contact J1-7 (wire 912-GY).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire 989-YL or in wire 912-GY of the machine harness. Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0392 FMI 05.Expected Result:The CID 0392 FMI 05 is active. Results:
YES - The CID 0392 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM
Parts adapter Caterpillar catalog:
1500195
ADAPTER KIT
Caterpillar
Caterpillar
1495146
ADAPTER
Caterpillar
Caterpillar
1494106
ADAPTER
Caterpillar
Caterpillar
1492884
ADAPTER-LARGE
Caterpillar
Caterpillar
1492883
ADAPTER-SMALL
Caterpillar
Caterpillar
1492878
ADAPTER-
Caterpillar
Caterpillar
1507191
ADAPTER
Caterpillar
Caterpillar
1506632
ADAPTER-FLAT
Caterpillar
Caterpillar
1506018
ADAPTER-HYD
Caterpillar
Caterpillar
1503617
ADAPTER-
Caterpillar
Caterpillar
1503111
ADAPTER
Caterpillar
Caterpillar
1502332
ADAPTER-
Caterpillar
Caterpillar