1783695 ADAPTER Caterpillar parts
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
Rating:
Alternative (cross code) number:
CA1783695
178-3695
1783695
CA1783695
178-3695
1783695
Weight: 1 pounds 0 kg.
MOTOR GRADER,
Compatible equipment models: 1783695:
Information:
HVAC Auto Climate Control Switch and HVAC ON Switch
Illustration 4 g03028517The A/C selector switch is used to determine the operating mode for the HVAC system. The rocker switch has three positions. Bottom position, (C) in previous figure, sets the HVAC system into automatic temperature control mode. ECM located on machine controls A/C compressor clutch, water valve position, and desired blower speed automatically. Optional blower speed override is still available to the operator by using dial (A). Center position, (D) in previous figure, sets the A/C system into off mode but still allows operator manual control of the water valve and blower speed through dials (A) and ( B). Top position, (E) in previous figure, sets the HVAC system into manual A/C mode. The A/C compressor is permanently turned on and the operator has manual control of the water valve and blower speed through dials ( A ) and (B).High/Low Pressure Switch
Illustration 5 g03030203
High-pressure switch
Illustration 6 g03030201
Low-pressure switch
High/Low pressure switch, used to prevent unwanted high pressure and low-pressure conditions on the outlet of the A/C compressor. Low-pressure switch, used to prevent unwanted low-pressure conditions on the inlet side of the A/C compressor. Both the high/low and low-pressure sensors prevent operation of the A/C compressor during conditions of overcharge of the refrigerant and undercharge of the refrigerant.HVAC Evaporator Thermostat Switch
Illustration 7 g03028287The HVAC evaporator thermostat switch is a passive analog signal to the Implement ECM. This sensor is used to measure the temperature of the evaporator coil. The sensors operating range is MAX 120° C (248° F), MIN −40° C (−40° F).Outputs
Clutches
HVAC A/C Clutch
Illustration 8 g03032419
Illustration 9 g03035238
(3) Magnetic clutch and pulley assembly
(4) Coil assembly
(5) Drive plate
(6) Bearing
(7) Compressor shaft The Implement ECM energizes the air conditioning clutch when the operator requests air conditioning and all of the conditions have been met.The compressor is driven by the engine. A belt connects the engine to the clutch and pulley assembly (3). The pulley assembly is located on the clutch. The drive plate (5) is fastened to the shaft of the compressor. The clutch and pulley assembly (3) turns on the bearing (6). The clutch and pulley assembly (3) are not connected to the shaft (7). The electric current from the thermostat controls a magnetic field in the coil assembly (4).The magnetic field pulls the drive plate (5) against the clutch and pulley assembly (3). The clutch and the pulley assembly (3) turns the shaft (7) that operates the compressor. When the current to the coil assembly (4) is stopped, the magnetic field is removed. This allows the drive plate (5) to move away from the clutch and pulley assembly (3). The clutch and the pulley assembly (3) will turn freely on the bearing (6). The sequence of connecting and disconnecting the pulley to the compressor shaft (7) is called compressor cycling. The compressor cycling is controlled by the thermostat . The thermostat is controlled by the capillary tube, which is installed between the fins of the evaporator coil.Actuators
HVAC Water Valve Continuous Signal (Electronic Rotational Actuator)
Illustration 10 g03031876Electronic rotational
Illustration 4 g03028517The A/C selector switch is used to determine the operating mode for the HVAC system. The rocker switch has three positions. Bottom position, (C) in previous figure, sets the HVAC system into automatic temperature control mode. ECM located on machine controls A/C compressor clutch, water valve position, and desired blower speed automatically. Optional blower speed override is still available to the operator by using dial (A). Center position, (D) in previous figure, sets the A/C system into off mode but still allows operator manual control of the water valve and blower speed through dials (A) and ( B). Top position, (E) in previous figure, sets the HVAC system into manual A/C mode. The A/C compressor is permanently turned on and the operator has manual control of the water valve and blower speed through dials ( A ) and (B).High/Low Pressure Switch
Illustration 5 g03030203
High-pressure switch
Illustration 6 g03030201
Low-pressure switch
High/Low pressure switch, used to prevent unwanted high pressure and low-pressure conditions on the outlet of the A/C compressor. Low-pressure switch, used to prevent unwanted low-pressure conditions on the inlet side of the A/C compressor. Both the high/low and low-pressure sensors prevent operation of the A/C compressor during conditions of overcharge of the refrigerant and undercharge of the refrigerant.HVAC Evaporator Thermostat Switch
Illustration 7 g03028287The HVAC evaporator thermostat switch is a passive analog signal to the Implement ECM. This sensor is used to measure the temperature of the evaporator coil. The sensors operating range is MAX 120° C (248° F), MIN −40° C (−40° F).Outputs
Clutches
HVAC A/C Clutch
Illustration 8 g03032419
Illustration 9 g03035238
(3) Magnetic clutch and pulley assembly
(4) Coil assembly
(5) Drive plate
(6) Bearing
(7) Compressor shaft The Implement ECM energizes the air conditioning clutch when the operator requests air conditioning and all of the conditions have been met.The compressor is driven by the engine. A belt connects the engine to the clutch and pulley assembly (3). The pulley assembly is located on the clutch. The drive plate (5) is fastened to the shaft of the compressor. The clutch and pulley assembly (3) turns on the bearing (6). The clutch and pulley assembly (3) are not connected to the shaft (7). The electric current from the thermostat controls a magnetic field in the coil assembly (4).The magnetic field pulls the drive plate (5) against the clutch and pulley assembly (3). The clutch and the pulley assembly (3) turns the shaft (7) that operates the compressor. When the current to the coil assembly (4) is stopped, the magnetic field is removed. This allows the drive plate (5) to move away from the clutch and pulley assembly (3). The clutch and the pulley assembly (3) will turn freely on the bearing (6). The sequence of connecting and disconnecting the pulley to the compressor shaft (7) is called compressor cycling. The compressor cycling is controlled by the thermostat . The thermostat is controlled by the capillary tube, which is installed between the fins of the evaporator coil.Actuators
HVAC Water Valve Continuous Signal (Electronic Rotational Actuator)
Illustration 10 g03031876Electronic rotational
Cat SIS web machinery list:
Parts adapter Caterpillar catalog:
9X0262
ADAPTER
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 143H, 14H, 14M, 160H, 160K, 160M, 160M 2, 163H, 16H, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 30/30, 3114, 3116, 31...
120H, 120K, 120K 2, 12H, 12K, 12M, 135H, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 143H, 14H, 14M, 160H, 160K, 160M, 160M 2, 163H, 16H, 16M, 2290, 2390, 2391, 2491, 24H, 24M, 2590, 30/30, 3114, 3116, 31...
2P8421
ADAPTER-O-RING
1090, 1190, 1190T, 120M, 120M 2, 1290T, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14M, 153, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H NA, 16M, 173B, 183B, 193, 2590, 308...
1090, 1190, 1190T, 120M, 120M 2, 1290T, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14M, 153, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H NA, 16M, 173B, 183B, 193, 2590, 308...
8T2353
ADAPTER
120G, 120H, 120K, 120K 2, 12G, 12H, 12H NA, 12K, 12M, 12M 2, 130G, 135H, 140G, 140H, 140H NA, 140K, 140K 2, 140M, 140M 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160K, 160M 2, 163H, 16G, 216, 228, 2290, 2...
120G, 120H, 120K, 120K 2, 12G, 12H, 12H NA, 12K, 12M, 12M 2, 130G, 135H, 140G, 140H, 140H NA, 140K, 140K 2, 140M, 140M 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160K, 160M 2, 163H, 16G, 216, 228, 2290, 2...
5K6875
ADAPTER
120G, 120H, 12G, 130G, 135H, 135H NA, 140G, 14G, 160H, 160H ES, 160H NA, 163H NA, 215, 215B, 216, 216B, 226B, 228, 232B, 236, 236B, 242B, 246C, 247, 247B, 248, 252B, 256C, 257B, 262C, 267, 272C, 277C,...
120G, 120H, 12G, 130G, 135H, 135H NA, 140G, 14G, 160H, 160H ES, 160H NA, 163H NA, 215, 215B, 216, 216B, 226B, 228, 232B, 236, 236B, 242B, 246C, 247, 247B, 248, 252B, 256C, 257B, 262C, 267, 272C, 277C,...
6V7420
ADAPTER
120G, 120H, 120K, 120K 2, 12K, 135H, 140K, 140K 2, 143H, 14H, 160K, 163H NA, 16G, 16M, 216, 236, 247, 267, 287, 305.5, 308D, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 32...
120G, 120H, 120K, 120K 2, 12K, 135H, 140K, 140K 2, 143H, 14H, 160K, 163H NA, 16G, 16M, 216, 236, 247, 267, 287, 305.5, 308D, 3126B, 3126E, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 32...
7D4903
ADAPTER
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16...
3P1823
ADAPTER-PIPE
10-20B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 245, 24M, 311D LRR, 311F LRR, 320 L, 3208, 320B FM LL, 320C F...
10-20B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 235, 245, 24M, 311D LRR, 311F LRR, 320 L, 3208, 320B FM LL, 320C F...
1025829
ADAPTER
12H, 140H, 143H, 14H, 14M, 160H, 163H, 16H, 16M, 24M, 3176B, 3176C, 3196, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 340D L, 345B, 345B II, 345B II...
12H, 140H, 143H, 14H, 14M, 160H, 163H, 16H, 16M, 24M, 3176B, 3176C, 3196, 330C, 330C FM, 330C L, 330C MH, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 340D L, 345B, 345B II, 345B II...
3P1932
ADAPTER
120H, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H NA, 14M, 160H, 160H ES...
120H, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H NA, 14M, 160H, 160H ES...
1910522
ADAPTER
120K, 120K 2, 12K, 12M, 140G, 140K, 140K 2, 140M, 160K, 3126E, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, 525C, 53...
120K, 120K 2, 12K, 12M, 140G, 140K, 140K 2, 140M, 160K, 3126E, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, 525C, 53...
2W9094
ADAPTER-EXHAUST
12G, 12H, 12H NA, 3304
12G, 12H, 12H NA, 3304
5F9999
ADAPTER
12H, 12K, 140H, 140K, 140K 2, 160H, 160K, 621E, 631E, 824, 834, 950, 966C, 980
12H, 12K, 140H, 140K, 140K 2, 160H, 160K, 621E, 631E, 824, 834, 950, 966C, 980
1940639
ADAPTER-FAN
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
6G5765
ADAPTER GP
16G, 16H NA
16G, 16H NA
6G4833
ADAPTER
16G, 16H, 16H NA, 24H
16G, 16H, 16H NA, 24H
5T8060
ADAPTER
16G, 16H, 16H NA, 16M, 24H, 24M
16G, 16H, 16H NA, 16M, 24H, 24M
2W8761
ADAPTER-FAN
16G, 16H NA
16G, 16H NA
6G4680
ADAPTER
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
1396815
ADAPTER
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
1331570
ADAPTER
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
1376605
ADAPTER
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
9U8073
ADAPTER
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
9N4155
ADAPTER
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
1180424
ADAPTER
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA