Information:
Fire Suppression Control (Automatic)
Illustration 1 g03323739
The fire suppression control is located in the operator station.Audio Sounder (1) - The audio sounder gives the audio indication for all alarm and fault outputs. The audio sounder will pulse at the same rate as the corresponding indicator.Key Switch (2) - Used to isolate the release circuit when maintenance is performed on the fire suppression system.Fault (Amber) (3) - This indicator and the audio sounder will pulse once every 10 seconds when indicating a system fault. The fault indicator returns to a normal condition when the fault is cleared.Power (Green) (4) - This indicator pulses once every 2 seconds to indicate normal battery power. The indicator will be off to indicate a loss of power or a low-power condition.Alarm (Red) (5) - This indicator and the audio sounder will pulse 2 times per second for 10 seconds at the start of an alarm condition. This indicator and the audio sounder will pulse four times per second for 10 seconds from the start of shutdown until discharge. An alarm condition is caused by the detection of a fire or by the operation of a manual actuator. The indicator and the audio sounder will pulse until the source of the alarm is removed and the fire suppression control is reset.Discharge (Red) (6) - This indicator and the audio sounder will pulse 4 times per second during the discharge event.Shutdown (Red) (7) - This indicator and the audio sounder will pulse 4 times per second for 5 seconds during the shutdown period.Isolated (Amber) (8) - This indicator and the audio sounder will pulse for 2 seconds at 60 second intervals when the release circuit is isolated.Delay Button (9) - The "DELAY" button is used to perform three different functions:
Delay the shutdown relay operation
Activate the LED diagnostic code in a fault condition
Reset the control panelFollowing the activation of the fire suppression system, the audio sounder, the alarm indicator, the discharge indicator and the shutdown indicator will pulse once every 10 seconds.Fire Suppression Control (Manual)
Manual actuation of the fire suppression system will result in immediate system discharge which may obscure vision and affect the operator's ability to control the machine. This may result in personal injury or death. Make certain the machine is stopped safely before manually actuating the system. Manual actuation will bypass all auxiliary shutdown and alarm functions.
Illustration 2 g02724663
Illustration 3 g02724661
There are two manual actuators on the machine.Manual actuator (10) is located in the operator station of the machine. Manual actuator (13) is located on the right side rear fender.Activate the fire suppression system by pulling the ring pin on manual actuator (10) or (13) and striking red button (11) or (12) .In Case of Fire
In case of fire, evacuate the area to reduce the risk of injury from flames, heat, hazardous vapors, explosions, or any other hazards that may be created.
The following procedure should be read and performed in accordance with the current mine site practices.In case of fire perform the following procedure:
When the system alarm
Illustration 1 g03323739
The fire suppression control is located in the operator station.Audio Sounder (1) - The audio sounder gives the audio indication for all alarm and fault outputs. The audio sounder will pulse at the same rate as the corresponding indicator.Key Switch (2) - Used to isolate the release circuit when maintenance is performed on the fire suppression system.Fault (Amber) (3) - This indicator and the audio sounder will pulse once every 10 seconds when indicating a system fault. The fault indicator returns to a normal condition when the fault is cleared.Power (Green) (4) - This indicator pulses once every 2 seconds to indicate normal battery power. The indicator will be off to indicate a loss of power or a low-power condition.Alarm (Red) (5) - This indicator and the audio sounder will pulse 2 times per second for 10 seconds at the start of an alarm condition. This indicator and the audio sounder will pulse four times per second for 10 seconds from the start of shutdown until discharge. An alarm condition is caused by the detection of a fire or by the operation of a manual actuator. The indicator and the audio sounder will pulse until the source of the alarm is removed and the fire suppression control is reset.Discharge (Red) (6) - This indicator and the audio sounder will pulse 4 times per second during the discharge event.Shutdown (Red) (7) - This indicator and the audio sounder will pulse 4 times per second for 5 seconds during the shutdown period.Isolated (Amber) (8) - This indicator and the audio sounder will pulse for 2 seconds at 60 second intervals when the release circuit is isolated.Delay Button (9) - The "DELAY" button is used to perform three different functions:
Delay the shutdown relay operation
Activate the LED diagnostic code in a fault condition
Reset the control panelFollowing the activation of the fire suppression system, the audio sounder, the alarm indicator, the discharge indicator and the shutdown indicator will pulse once every 10 seconds.Fire Suppression Control (Manual)
Manual actuation of the fire suppression system will result in immediate system discharge which may obscure vision and affect the operator's ability to control the machine. This may result in personal injury or death. Make certain the machine is stopped safely before manually actuating the system. Manual actuation will bypass all auxiliary shutdown and alarm functions.
Illustration 2 g02724663
Illustration 3 g02724661
There are two manual actuators on the machine.Manual actuator (10) is located in the operator station of the machine. Manual actuator (13) is located on the right side rear fender.Activate the fire suppression system by pulling the ring pin on manual actuator (10) or (13) and striking red button (11) or (12) .In Case of Fire
In case of fire, evacuate the area to reduce the risk of injury from flames, heat, hazardous vapors, explosions, or any other hazards that may be created.
The following procedure should be read and performed in accordance with the current mine site practices.In case of fire perform the following procedure:
When the system alarm
Caterpillar parts catalog:
Parts adapter Caterpillar catalog:
1140466
ADAPTER-TIP
345B II, 980G, 980G II, 986H, 988B, 988F, 988F II, 988G
345B II, 980G, 980G II, 986H, 988B, 988F, 988F II, 988G
1140465
ADAPTER-TIP
345B II, 980G, 980G II, 986H, 988B, 988F, 988F II, 988G
345B II, 980G, 980G II, 986H, 988B, 988F, 988F II, 988G
8E3465
ADAPTER-STRAP
988B, 988F
988B, 988F
8J6397
ADAPTER-CORNER
988, 988B
988, 988B
4T7455
ADAPTER-STRAP
988B
988B
1258405
ADAPTER-TIP
980C, 980F, 980F II, 980G, 980G II
980C, 980F, 980F II, 980G, 980G II
1258404
ADAPTER
980C, 980F, 980F II, 980G, 980G II
980C, 980F, 980F II, 980G, 980G II
1258406
ADAPTER-TIP
980C, 980F, 980F II, 980G, 980G II
980C, 980F, 980F II, 980G, 980G II
1073555
ADAPTER-TIP
988F II, 988G, 990, 990 II, 990H, 992D, 992G
988F II, 988G, 990, 990 II, 990H, 992D, 992G
1073556
ADAPTER-TIP
988F II, 988G, 990, 990 II, 990H, 992D, 992G
988F II, 988G, 990, 990 II, 990H, 992D, 992G
6I9898
ADAPTER-TIP
980G, 980G II
980G, 980G II
6I8244
ADAPTER-TIP
980G, 980G II
980G, 980G II
3091110
ADAPTER-TIP
972H
972H
1620476
ADAPTER AS
980H, AS3143, CD-54, CR3, MH3049, MH3059, PC206, PS-360B, PS-360C, PW2503/7
980H, AS3143, CD-54, CR3, MH3049, MH3059, PC206, PS-360B, PS-360C, PW2503/7
3081190
ADAPTER
966H, 966K, 966M, 966M XE, 972H, 972K, 972M, 972M XE, 980C, 980K, 980K HLG, 980M, 982M
966H, 966K, 966M, 966M XE, 972H, 972K, 972M, 972M XE, 980C, 980K, 980K HLG, 980M, 982M
2249922
ADAPTER AS-STEERING COLUMN
836H, 950H, 962H, 966H, 972H, 980H
836H, 950H, 962H, 966H, 972H, 980H
2462951
ADAPTER
777G, 785D, 966H, 972H
777G, 785D, 966H, 972H
3G4554
ADAPTER-- CENTE--R FLUSH MOUNT
5110B, 5130, 5130B, 990, 990 II, 992C
5110B, 5130, 5130B, 990, 990 II, 992C