4248756 ADAPTER Caterpillar parts
Rating:
Alternative (cross code) number:
CA4248756
424-8756
4248756
CA4248756
424-8756
4248756
Weight: 53 pounds 24 kg.
Information:
Table 1
Event Code    
Description    Conditions which Activate the Code    System Response    
E264 (3) Emergency Stop Activated     An "Emergency Stop" button is pressed.     The shutdown output is activated. The Electronic Control Module (ECM) de-energizes the gas shutoff valve. the ECM terminates the ignition. The code is logged.    
E268 (3) Unexpected Engine Shutdown     The "crank terminate relay" output is on. However, the engine speed is less than the "postlube speed".     The shutdown output is activated. The code is logged. The engine is shut down.    
E269 (3) Customer Shutdown Requested     The engine is either cranking or running. The "normal stop" input is disconnected from the digital return or from the -Battery.    Note: Refer to Troubleshooting, "Engine Monitoring System" for information on trip points and delay times.The ignition is immediately terminated when an emergency stop button is pressed. Unburned gas remains in the air inlet and exhaust system.
Unburned gas in the air inlet and exhaust system may ignite when the engine is started. Personal injury and/or property damage may result.Before starting an engine that may contain unburned gas, purge the unburned gas from the air inlet and exhaust system. Refer to the topic on purging unburned gas in the "Starting the Engine" section.
Probable Causes For a 264-3 or 269-3 Code
The "Emergency Stop" button is pressed.
The circuit for the emergency stop is faulty.
The "normal stop" input is not connected to the digital return or to the -Battery.Probable Causes For a 268-3 Code
There is a problem with the Gas Shutoff Valve (GSOV).
Incorrect inputs for the mode of operation to the master Electronic Control Module (ECM)
There is a problem with the "Crank Terminate" relay.
There is a problem with the relay for the starting motor.
A shutdown has been requested by the driven equipment.
There is a problem with the "Run" relay.
The "Crank Terminate Speed" is incorrectly programmed.
The "Cycle Crank Time" is incorrectly programmed.
The "Engine Overcrank Time" is incorrectly programmed.
The delay time for the driven equipment is excessive.
There is a problem with the harness code for an ECM .
There is a problem with the input for the keyswitch to the throttle actuator. The throttle will not respond to commands from the master ECM when the input is low.Recommended Repairs For a 264-3 or 269-3 Code
Talk to the operator
Ask the operator if the stop was intentional. Make sure that the reason for the stop has been corrected. Reset the control system. Resume normal operation.If the stop was accidental, reset the control system. Resume normal operation.Check the Circuit for the Stop Switches
Note: The circuit for the normal stop switch and the circuit for the emergency stop switch must remain closed in order for the engine to run.Inspect the wiring between the switches and the connector of the electronic control module. Look for damage and/or corrosion. Refer to Troubleshooting, "Electrical Connectors - Inspect".For the emergency stop switch, close the switch and check the resistance between terminals P1-22 and P1-31. The expected value is less than five Ohms.For the
Caterpillar parts catalog:
Parts adapter Caterpillar catalog:
4238673
ADAPTER
Caterpillar
Caterpillar
4216188
ADAPTER
Caterpillar
Caterpillar
4170917
ADAPTER AS
Caterpillar
Caterpillar
3985639
ADAPTER AS
Caterpillar
Caterpillar
3979733
ADAPTER
Caterpillar
Caterpillar
3979732
ADAPTER
Caterpillar
Caterpillar
4392704
ADAPTER AS-EXHAUST
Caterpillar
Caterpillar
4372298
ADAPTER
Caterpillar
Caterpillar
4367064
ADAPTER
Caterpillar
Caterpillar
4302787
ADAPTER GP-AIR INLET MANIFOLD
Caterpillar
Caterpillar
4271295
ADAPTER-SEAL
Caterpillar
Caterpillar
4264164
ADAPTER
Caterpillar
Caterpillar