Use this procedure to troubleshoot an engine with high manifold DEF temperature. Also, use this procedure if one of the following event codes is active or logged.
Table 1
J1939 Code and Description CDL Code and Description Comments
4337-15
Aftertreatment #1 DEF Doser #1 Temperature : High - least severe (1) E934(1)
High Aftertreatment #1 DEF Temperature #1 The DEF manifold temperature is too high.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
4357-5 3604-5 Troubleshooting, "Solenoid Valve - Test"
4357-6 3605-6 Troubleshooting, "Solenoid Valve - Test" Probable Causes
Code
DEF manifold heater
SensorRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Apply electrical power to the engine.
B. Connect Cat® Electronic Technician (ET) to the service tool connector.
C. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is present.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A 4337-15 code is present.
Proceed to Test Step 2.
2. Check the DEF Manifold Heater
A. Remove electrical power from the engine.
B. Disconnect the DEF manifold heater from the wiring harness connector.
C. Apply electrical power to the engine.
D. Measure the voltage on the DEF manifold heater wiring harness connector.
24 VDC
Result: There was NOT 24 VDC at the DEF tank manifold connector.
Proceed to Test Step 3.
Return to service.
Result: There was 24 VDC at the DEF tank manifold connector.
Repair: Replace the DEF manifold heater relay.
3. Check the DEF Manifold Temperature Sensor
A. Apply electrical power to the engine.
B. Connect Cat ET.
C. Monitor the "DEF Dosing Reagent Temperature"
D. The "DEF Dosing Reagent Temperature"should be within 5° C (9° F) of ambient temperature.
DEF Manifold Temperature
Result: The "DEF Dosing Reagent Temperature" is within 5° C (9° F) of ambient temperature.
Verify that the repair eliminated the problem.
Result: The "DEF Dosing Reagent Temperature" is greater 5° C (9° F) of ambient temperature.
Repair: Replace the DEF manifold temperature sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Table 1
J1939 Code and Description CDL Code and Description Comments
4337-15
Aftertreatment #1 DEF Doser #1 Temperature : High - least severe (1) E934(1)
High Aftertreatment #1 DEF Temperature #1 The DEF manifold temperature is too high.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
4357-5 3604-5 Troubleshooting, "Solenoid Valve - Test"
4357-6 3605-6 Troubleshooting, "Solenoid Valve - Test" Probable Causes
Code
DEF manifold heater
SensorRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Apply electrical power to the engine.
B. Connect Cat® Electronic Technician (ET) to the service tool connector.
C. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is present.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A 4337-15 code is present.
Proceed to Test Step 2.
2. Check the DEF Manifold Heater
A. Remove electrical power from the engine.
B. Disconnect the DEF manifold heater from the wiring harness connector.
C. Apply electrical power to the engine.
D. Measure the voltage on the DEF manifold heater wiring harness connector.
24 VDC
Result: There was NOT 24 VDC at the DEF tank manifold connector.
Proceed to Test Step 3.
Return to service.
Result: There was 24 VDC at the DEF tank manifold connector.
Repair: Replace the DEF manifold heater relay.
3. Check the DEF Manifold Temperature Sensor
A. Apply electrical power to the engine.
B. Connect Cat ET.
C. Monitor the "DEF Dosing Reagent Temperature"
D. The "DEF Dosing Reagent Temperature"should be within 5° C (9° F) of ambient temperature.
DEF Manifold Temperature
Result: The "DEF Dosing Reagent Temperature" is within 5° C (9° F) of ambient temperature.
Verify that the repair eliminated the problem.
Result: The "DEF Dosing Reagent Temperature" is greater 5° C (9° F) of ambient temperature.
Repair: Replace the DEF manifold temperature sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts additive Caterpillar catalog:
2170617
ADDITIVE
Caterpillar
Caterpillar
2170616
ADDITIVE
Caterpillar
Caterpillar
1U6532
ADDITIVE
Caterpillar
Caterpillar
1U5577
ADDITIVE-DYE
Caterpillar
Caterpillar
1U5576
ADDITIVE-DYE
Caterpillar
Caterpillar
1U5575
ADDITIVE-DYE
Caterpillar
Caterpillar
7R4437
ADDITIVE SYSTE
Caterpillar
Caterpillar
5P2907
ADDITIVE
Caterpillar
Caterpillar
4639809
ADDITIVE-BULK
Caterpillar
Caterpillar
4547024
ADDITIVE OIL
Caterpillar
Caterpillar
4236581
ADDITIVE-BULK
Caterpillar
Caterpillar
3P2044
ADDITIVE
Caterpillar
Caterpillar