1077197 AFTERCOOLER GP-TREATED WATER Caterpillar parts
3516, 3516B, 5230B, 789, 789B, 789C, 789D, 994D, 994F, 994H, PM3516, PP3516
Rating:
Alternative (cross code) number:
CA1077197
107-7197
1077197
CA1077197
107-7197
1077197
GEN SET ENGINE, WHEEL LOADER,
This part in 4 request:
Show.
This information for suppliers only!
2023-12-05
2023-12-02
2023-11-28
2023-11-27
Compatible equipment models: 1077197:
Caterpillar SIS machinery equipment:
Caterpillar SIS
789B Off-HighwayTruck 7EK00001-UP (MACHINE) POWERED BY 3516 Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set Engine 7RN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set Engine 6HN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Engine 8KN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Auxiliary Engine 9AN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Auxiliary Engine 2FW00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Engine 3CW00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set Engine 1NW00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set 8NW00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
789C Off-Highway Truck 2BW00001-UP (MACHINE) POWERED BY 3516 Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
994D WHEEL LOADER 3TZ00001-UP (MACHINE) POWERED BY 3516B Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
5230B Excavator 4HZ00001-UP (MACHINE) POWERED BY 3516B Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Locomotive Engine 6HZ00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Locomotive Engine 9WF00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
PM3516 Power Module BPD00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Industrial Engine CAN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set FDN00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set BMB00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
PP3516 Power Package PPS00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
994F Wheel Loader 44200001-UP (MACHINE) POWERED BY 3516 Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Auxiliary Engine S2P00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Auxiliary Engine S2R00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Engine S2S00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Marine Engine S2W00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set GZS00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set GZY00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set Oil Field Land Rig LEK00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set ZAP00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set YAP00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
789D Off-Highway Truck SPD00001-UP (MACHINE) POWERED BY 3516 Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set YAT00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
PM3516 3516B Power Module NBR00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
994H Wheel Loader DWC00001-UP (MACHINE) POWERED BY 3516B Engine »
107-7197
AFTERCOOLER GP-TREATED WATER
3516 Engine Emissions Upgrade Group Retrofit To Tier I Equivalent Level 29Z01095-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set YBT00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set ZBP00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set GSA00001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Custom Engine For 789C Off-Highway Truck 2BW00001-UP (MACHINE) »
107-7197
AFTERCOOLER GP-TREATED WATER
3516B Generator Set GD300001-UP »
107-7197
AFTERCOOLER GP-TREATED WATER
3516 Engine Emissions Certified Rebuild Upgrade Retrofit Tier I Equivalent Level for 789 Off-Highway Truck 9ZC00001-UP (MACHINE) »
107-7197
AFTERCOOLER GP-TREATED WATER
Cat SIS web machinery list:
Information:
Storage - Greater than 7 Days and less than 30 Days
Caterpillar recommends maintaining the temperature of the engine to a temperature of at least 5° C (9° F) above ambient temperature to prevent corrosion. The usage of jacket water heaters is an appropriate method.Storage - Greater than 30 Days and less than 1 Year
Engine Storage
Note: If long-term storage for time exceeding 1 year is necessary, contact your local Caterpillar Dealer for the preferred procedure to use in your specific case.If the engine will not be started for several weeks, the lubricating oil will drain from the cylinder walls and from the piston rings. Rust can form on the cylinder liner surface, which will increase engine wear which can reduce engine service life.To help prevent excessive engine wear, use the following guidelines:
Complete all the lubrication recommendations that are listed in this Operation and Maintenance Manual, "Maintenance Interval Schedule" (Maintenance Section).
If freezing temperatures are expected, check the cooling system for adequate protection against freezing. See this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).If an engine is out of operation and if use of the engine is not planned, special precautions should be made. If the engine will be stored for more than one month, a complete protection procedure is recommended.For more detailed information on engine storage, see Special Instruction, SEHS9031, "Storage Procedure for Caterpillar Products".Generator Storage
A storage period in excess of six months should be preceded by the following preparation:
Install desiccant bags inside the exciter's cover and install desiccant bags inside the screen of the fan.
Seal the unit in a covering of plastic or other material that has been designed for that purpose.
Adequately tag the generator. This will ensure that preservative greases and desiccant bags are removed before the generator is placed in operation.Bearing Inspection
Ball bearing generators use grease. This grease is subject to deterioration. If the generator is stored more than one year, new ball bearings may be required. These bearings should be greased prior to being put into operation. If inspection indicates that bearings are free of rust or corrosion, and no noise or excessive vibration appear on start-up, replacement is not necessary.Electrical Measurements
Measure the insulation resistance of each winding if the generator was exposed to the following conditions:
Rapid changes in temperature
Freezing
Wet climate during storageNote: These tests should be conducted prior to any power connections that are being made. These tests should be conducted prior to any control connections that are made.Refer to the Generator Maintenance section of this manual to measure the following items:
Exciter Field (Stator)
Exciter Armature (Rotor)
Generator Field (Rotor)
Generator Armature (Stator)For additional information on generator storage, consult your Caterpillar dealer for assistance.
Caterpillar recommends maintaining the temperature of the engine to a temperature of at least 5° C (9° F) above ambient temperature to prevent corrosion. The usage of jacket water heaters is an appropriate method.Storage - Greater than 30 Days and less than 1 Year
Engine Storage
Note: If long-term storage for time exceeding 1 year is necessary, contact your local Caterpillar Dealer for the preferred procedure to use in your specific case.If the engine will not be started for several weeks, the lubricating oil will drain from the cylinder walls and from the piston rings. Rust can form on the cylinder liner surface, which will increase engine wear which can reduce engine service life.To help prevent excessive engine wear, use the following guidelines:
Complete all the lubrication recommendations that are listed in this Operation and Maintenance Manual, "Maintenance Interval Schedule" (Maintenance Section).
If freezing temperatures are expected, check the cooling system for adequate protection against freezing. See this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).If an engine is out of operation and if use of the engine is not planned, special precautions should be made. If the engine will be stored for more than one month, a complete protection procedure is recommended.For more detailed information on engine storage, see Special Instruction, SEHS9031, "Storage Procedure for Caterpillar Products".Generator Storage
A storage period in excess of six months should be preceded by the following preparation:
Install desiccant bags inside the exciter's cover and install desiccant bags inside the screen of the fan.
Seal the unit in a covering of plastic or other material that has been designed for that purpose.
Adequately tag the generator. This will ensure that preservative greases and desiccant bags are removed before the generator is placed in operation.Bearing Inspection
Ball bearing generators use grease. This grease is subject to deterioration. If the generator is stored more than one year, new ball bearings may be required. These bearings should be greased prior to being put into operation. If inspection indicates that bearings are free of rust or corrosion, and no noise or excessive vibration appear on start-up, replacement is not necessary.Electrical Measurements
Measure the insulation resistance of each winding if the generator was exposed to the following conditions:
Rapid changes in temperature
Freezing
Wet climate during storageNote: These tests should be conducted prior to any power connections that are being made. These tests should be conducted prior to any control connections that are made.Refer to the Generator Maintenance section of this manual to measure the following items:
Exciter Field (Stator)
Exciter Armature (Rotor)
Generator Field (Rotor)
Generator Armature (Stator)For additional information on generator storage, consult your Caterpillar dealer for assistance.
Parts aftercooler Caterpillar catalog:
2W3715
AFTERCOOLER GP-WATER
789, 789B
789, 789B
1476620
AFTERCOOLER GP-WATER
3516B, 3516C, 793C, PM3516
3516B, 3516C, 793C, PM3516
8N0358
AFTERCOOLER GP-WATER
3516, 3516B, PM3516
3516, 3516B, PM3516
2552288
AFTERCOOLER GP-WATER
3512, 3516, 3516B, 3516C
3512, 3516, 3516B, 3516C
1077194
AFTERCOOLER GP-WATER
3516, 3516B, 785C, 789C
3516, 3516B, 785C, 789C
1360596
AFTERCOOLER GP-WATER
525B, 535B, 539, 550, 570, 574, 580, 938G, 950F, 950F II, 950G, 960F, 962G, AP-1000B, AP-1055B, BG-2455C, BG-245C, IT38G, IT62G
525B, 535B, 539, 550, 570, 574, 580, 938G, 950F, 950F II, 950G, 960F, 962G, AP-1000B, AP-1055B, BG-2455C, BG-245C, IT38G, IT62G
3559692
AFTERCOOLER GP-WATER
3208, C175-16, C175-20
3208, C175-16, C175-20
2679530
AFTERCOOLER GP-WATER
G3516C, G3516E, G3520C, G3520E
G3516C, G3516E, G3520C, G3520E
3615226
AFTERCOOLER GP-AIR
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH
M313D, M315D, M316D, M318D, M318D MH, M322D, M322D MH
6I2885
AFTERCOOLER GP-WATER
814F, 815F, 816F, 966F II, 970F, 972G
814F, 815F, 816F, 966F II, 970F, 972G
3719543
AFTERCOOLER GP-WATER
3406B, 3406C
3406B, 3406C
6N7948
AFTERCOOLER GP-AUXILIARY
3406, 3406B, 3406C
3406, 3406B, 3406C
6N5960
AFTERCOOLER GP-WATER
3126, 3306, 3306B, G3306, G3306B, R1300, R1300G
3126, 3306, 3306B, G3306, G3306B, R1300, R1300G
2383319
AFTERCOOLER GP-WATER
G3516C, G3516E, G3520C, G3520E, PMG3516
G3516C, G3516E, G3520C, G3520E, PMG3516