3928074 AIR CLEANER GP Caterpillar parts
236D, 242D, 257D, 259D
Rating:
Alternative (cross code) number:
CA3928074
392-8074
3928074
CA3928074
392-8074
3928074
Weight: 6 pounds 2 kg.
COMPACT TRACK LOADER, SKID STEER LOADER,
Compatible equipment models: 3928074:
Information:
Introduction
By default, the Light Bar Scales option is available for all configurations of AccuGrade GPS system. Depending on the operator configuration settings for your system, some of the options, soft keys, or views discussed in this manual may not be accessible.Operate to an on-grade tolerance threshold appropriate for the design surface. The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the light bars. The horizontal and vertical light bars are set independently of each other.Tolerance Thresholds
A tolerance threshold for vertical light bars is the distance off-grade at which two LEDs will be lit. A tolerance threshold for horizontal light bars is the distance off-line at which two LEDs will be lit.When the blade is on-grade (on-line) to within half the tolerance threshold, only the center green LED on the appropriate light bar is lit. As the blade moves offgrade (off-line), additional LEDs are lit.Other LED distances are automatically scaled from the tolerance threshold.The vertical tolerance threshold also determines the on-grade tolerance. The on-grade tolerance is the vertical range where the blade is considered to be on-grade. When the blade is in the on-grade range, the Cut/Fill text items and the associated direction arrow are green.When the blade is out of the on-grade range, one of the following things will occur:
The Cut text item and the down arrow will be red.
The Fill text item and the up arrow will be blue.Setting the Light Bar Scales
In order to set the tolerance thresholds, complete the following steps:
From the Setup Menu – Configuration dialog, press the Down arrow or the Up arrow until "Light Bar Scales" is highlighted.
Illustration 1 g01120754
Press the OK key. Refer to Illustration 1.
In the Light Bar Scales dialogs, press "Vertical" in order to set the vertical light bar scale. Use any of the following tools to edit the vertical tolerance value:
If you work in meters, press "Default Set 0.050" to set your tolerance to the default value of 0.050 m. If you work in US FT or feet, press "Default Set 0.200".
Use the arrow keys to enter the off-grade distance at which two vertical LEDs are lit. Enter a value between 0 and 3.810 m. The remaining threshold values are calculated automatically and appear in the dialog.
Press "Half Set 0.025" to set your tolerance to half of the current tolerance.
Press "Double Set 0.100" to set your tolerance to double the current tolerance.This vertical tolerance value is used as the AccuGrade GPS off-grade limit when automatic controls are turned on. If the cut or fill value at either blade tip exceeds this tolerance for more than three seconds, then the blade will be considered to be off-grade.
Press the "Horizontal" soft key in order to set the horizontal light bar scale. Use any of the following tools to change the horizontal tolerance value:
If you work in meters, press "Default Set 0.100" in order to set your tolerance to the default value of "0.100 m". If you work in US FT or feet, press
By default, the Light Bar Scales option is available for all configurations of AccuGrade GPS system. Depending on the operator configuration settings for your system, some of the options, soft keys, or views discussed in this manual may not be accessible.Operate to an on-grade tolerance threshold appropriate for the design surface. The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the light bars. The horizontal and vertical light bars are set independently of each other.Tolerance Thresholds
A tolerance threshold for vertical light bars is the distance off-grade at which two LEDs will be lit. A tolerance threshold for horizontal light bars is the distance off-line at which two LEDs will be lit.When the blade is on-grade (on-line) to within half the tolerance threshold, only the center green LED on the appropriate light bar is lit. As the blade moves offgrade (off-line), additional LEDs are lit.Other LED distances are automatically scaled from the tolerance threshold.The vertical tolerance threshold also determines the on-grade tolerance. The on-grade tolerance is the vertical range where the blade is considered to be on-grade. When the blade is in the on-grade range, the Cut/Fill text items and the associated direction arrow are green.When the blade is out of the on-grade range, one of the following things will occur:
The Cut text item and the down arrow will be red.
The Fill text item and the up arrow will be blue.Setting the Light Bar Scales
In order to set the tolerance thresholds, complete the following steps:
From the Setup Menu – Configuration dialog, press the Down arrow or the Up arrow until "Light Bar Scales" is highlighted.
Illustration 1 g01120754
Press the OK key. Refer to Illustration 1.
In the Light Bar Scales dialogs, press "Vertical" in order to set the vertical light bar scale. Use any of the following tools to edit the vertical tolerance value:
If you work in meters, press "Default Set 0.050" to set your tolerance to the default value of 0.050 m. If you work in US FT or feet, press "Default Set 0.200".
Use the arrow keys to enter the off-grade distance at which two vertical LEDs are lit. Enter a value between 0 and 3.810 m. The remaining threshold values are calculated automatically and appear in the dialog.
Press "Half Set 0.025" to set your tolerance to half of the current tolerance.
Press "Double Set 0.100" to set your tolerance to double the current tolerance.This vertical tolerance value is used as the AccuGrade GPS off-grade limit when automatic controls are turned on. If the cut or fill value at either blade tip exceeds this tolerance for more than three seconds, then the blade will be considered to be off-grade.
Press the "Horizontal" soft key in order to set the horizontal light bar scale. Use any of the following tools to change the horizontal tolerance value:
If you work in meters, press "Default Set 0.100" in order to set your tolerance to the default value of "0.100 m". If you work in US FT or feet, press
Caterpillar SIS machinery equipment:
Caterpillar SIS
236D Skid Steer Loader BGZ00001-UP (MACHINE) POWERED BY C3.3B Engine »
392-8074
AIR CLEANER GP
242D Skid Steer Loader DZT00001-UP (MACHINE) POWERED BY C3.3B Engine »
392-8074
AIR CLEANER GP
257D Multi Terrain Loader D5T00001-UP (MACHINE) POWERED BY C3.3B Engine »
392-8074
AIR CLEANER GP
259D Compact Track Loader FTL00001-UP (MACHINE) POWERED BY C3.3B Engine »
392-8074
AIR CLEANER GP
236D Skid Steer Loader MPW00001-UP (MACHINE) »
392-8074
AIR CLEANER GP
242D Skid Steer Loader A9W00001-UP (MACHINE) »
392-8074
AIR CLEANER GP
257D Multi Terrain Loader EML00001-UP (MACHINE) »
392-8074
AIR CLEANER GP
259D Compact Track Loader FTK00001-UP (MACHINE) »
392-8074
AIR CLEANER GP
Caterpillar parts catalog:
Parts air Caterpillar catalog:
3453499
AIR CLEANER GP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
3453498
AIR CLEANER GP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
3456190
AIR CONDITIONER & MOUNTING GP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
3456163
AIR CONDITIONER AR
236D, 242D, 257D, 259D
236D, 242D, 257D, 259D
3608886
AIR COMPRESSOR GP
M313D, M315D
M313D, M315D
1861295
AIR CLEANER AR
330C, 330C FM, 330C L, 330C MH
330C, 330C FM, 330C L, 330C MH
3405704
AIR COMPRESSOR GP
C15, C18, CX31-C15I, CX35-P800, TH35-C15I
C15, C18, CX31-C15I, CX35-P800, TH35-C15I
4L3593
AIR CLEANER GROUP
D337F
D337F
2056641
AIR CLEANER GP
330C, 330C FM, 330C L, 330C MH
330C, 330C FM, 330C L, 330C MH
1273275
AIR CLEANER GP
938G, IT38G
938G, IT38G
7E7374
AIR COMPRESSOR GP
120H, 120H ES, 120H NA, 135H, 135H NA
120H, 120H ES, 120H NA, 135H, 135H NA
1046046
AIR COMPRESSOR GP
120H, 120H ES, 120H NA, 135H, 135H NA, 613C II, 950F II
120H, 120H ES, 120H NA, 135H, 135H NA, 613C II, 950F II
2704223
AIR CLEANER GP
770, 772
770, 772
3032033
AIR DRYER GP
120K, 120K 2