Illustration 1 g01267850
Schematic for the Bucket Raise SolenoidThis diagnostic code is associated with the Bucket Raise Solenoid. The FMI 03 means that the ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Conditions that could causes this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Disconnect the negative battery cable and turn the key start switch to the OFF position.
Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 from the ECM.
At the machine harness ECM connectors, measure the resistance from contact J1-55 (wire H803-BU) to all of the other contacts that are used in the J1 and connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire H803-BU and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe key start switch remains in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire H803-BU and socket at contact J1-55 from the harness connector.
Reconnect the negative battery cable and turn key start switch to the ON position.
Turn the key start switch to the ON position.
Observe the status of the active CID 0356 FMI 03 diagnostic code.Expected Result:The CID 0354 FMI 03 diagnostic code is no longer active. A CID 0354 FMI 05 diagnostic code is now active.Results:
YES - The CID 0354 FMI 03 diagnostic code is no longer active. A CID 0354 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit.
Reinstall the disconnected solenoid
Caterpillar SIS machinery equipment:
Cat SIS web machinery list:
Parts air Caterpillar catalog:
4772865
AIR CLEANER GP
Caterpillar
Caterpillar
4671940
AIR CLEANER GP
Caterpillar
Caterpillar
4592421
AIR DRYER GP
Caterpillar
Caterpillar
3963262
AIR COMPRESSOR GP
Caterpillar
Caterpillar
3883912
AIR CLEANER & MOUNTING GP
Caterpillar
Caterpillar
3807791
AIR CLEANER GP
Caterpillar
Caterpillar
5459505
AIR CLEANER GP
Caterpillar
Caterpillar
5328659
AIR CLEANER GP
Caterpillar
Caterpillar
5120472
AIR CLEANER GP
Caterpillar
Caterpillar
4983191
AIR CLEANER GP
Caterpillar
Caterpillar
4938104
AIR CLEANER GP
Caterpillar
Caterpillar
4876373
AIR COMPRESSOR GP
Caterpillar
Caterpillar