1644442 ALTERNATOR GP-CHARGING Caterpillar parts
572R II, D7R II
Rating:
Alternative (cross code) number:
CA1644442
164-4442
1644442
CA1644442
164-4442
1644442
PIPELAYER, TRACK-TYPE TRACTOR,
Caterpillar SIS machinery equipment:
Caterpillar SIS
D7R Track-Type Tractor AFG00001-UP (MACHINE) POWERED BY 3176C Engine »
164-4442
ALTERNATOR GP-CHARGING
D7R Series II TRACK-TYPE TRACTOR STD, XR Differential Steering AEC00001-01499 (MACHINE) POWERED BY 3176C Engine »
164-4442
ALTERNATOR GP-CHARGING
D7R Track-Type Tractor ACS00001-UP (MACHINE) POWERED BY 3176C Engine »
164-4442
ALTERNATOR GP-CHARGING
D7R Series ll Track-Type Tractor LGP Differential Steering ABJ00001-01499 (MACHINE) POWERED BY 3176C Engine »
164-4442
ALTERNATOR GP-CHARGING
572R Series II Pipelayer DSC00001-UP (MACHINE) POWERED BY 3176C Engine »
164-4442
ALTERNATOR GP-CHARGING
D7R SERIES II TRACK-TYPE TRACTOR /FINGER TIP CONTROL/ BNM00001-UP (MACHINE) POWERED BY 3176C ENGINE »
164-4442
CHARGING ALTERNATOR GROUP
D7R SERIES II TRACK-TYPE TRACTOR /DIFFERENTIAL STEERIN/ BNX00001-00900 (MACHINE) POWERED BY 3176C ENGINE »
164-4442
CHARGING ALTERNATOR GROUP
D7R SERIES II TRACK-TYPE TRACTOR /FINGER TIP CONTROL/ BPK00001-UP (MACHINE) POWERED BY 3176C ENGINE »
164-4442
CHARGING ALTERNATOR
D7R SERIES II TRACK-TYPE TRACTOR /DIFFERENTIAL STEERIN/ BPT00001-UP (MACHINE) POWERED BY 3176C ENGINE »
164-4442
CHARGING ALTERNATOR
Caterpillar parts catalog:
Information:
TYPE="LEVEL" DEPTH="1" @@@-->Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already present If a block load derating is required, refer to ISO 8268 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Power Factor
The power factor represents the efficiency of the load. The power factor is the ratio of apparent power to total power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors, controls, and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity. Controls can operate at any power factor. Variable frequency drivers and variable speed drivers can operate at any power factor. An uninterruptible power supply can operate at any power factor. In this case, the power factor can be between 0.4 and 1.0.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high power factor will result in full engine load that is less than the generator's rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Caterpillar generators are designed for a power factor of 0.8 lagging. Please consult your Caterpillar dealer in order to check the generator rating if operation at less than 0.7 lagging power factor is desired.Excitation Systems
Self-Excited Generators
Self-excited
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
When an electrical load is applied to a generator set, block loading occurs. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
engine transient response
voltage regulator response
type of the voltage regulator
altitude of operation of the generator set
type of load
the amount of load that is already present If a block load derating is required, refer to ISO 8268 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Power Factor
The power factor represents the efficiency of the load. The power factor is the ratio of apparent power to total power. This ratio is expressed as a decimal. The power factor represents the portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors. This current is called the reactive load. Engine power is not required to maintain the reactive load.In most applications, electric motors, controls, and transformers determine the power factor of the system. Induction motors usually have a power factor that is no larger than 0.8. Incandescent lighting is a resistive load of about 1.0 power factor, or unity. Controls can operate at any power factor. Variable frequency drivers and variable speed drivers can operate at any power factor. An uninterruptible power supply can operate at any power factor. In this case, the power factor can be between 0.4 and 1.0.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. With equal loads, a lower power factor will draw more current. A high power factor will result in full engine load that is less than the generator's rated amperage. A lower power factor increases the possibility of overloading the generator.Note: Normally, Caterpillar generators are designed for a power factor of 0.8 lagging. Please consult your Caterpillar dealer in order to check the generator rating if operation at less than 0.7 lagging power factor is desired.Excitation Systems
Self-Excited Generators
Self-excited
Parts alternator Caterpillar catalog:
3062174
ALTERNATOR GP-CHARGING
3406B, 3406C, 3412E, 3508B, 3512B, 3516B, 3516C, 583T, 587T, C-12, C11, C13, C15, C18, C27, C32, C7, C9, CX31-C13I, CX31-C15I, CX35-P800, D6R II, D6R III, D7R II, D8T, D9R, DEUCE, TH31-E61, TH35-C11I,...
3406B, 3406C, 3412E, 3508B, 3512B, 3516B, 3516C, 583T, 587T, C-12, C11, C13, C15, C18, C27, C32, C7, C9, CX31-C13I, CX31-C15I, CX35-P800, D6R II, D6R III, D7R II, D8T, D9R, DEUCE, TH31-E61, TH35-C11I,...
3167251
ALTERNATOR GP-CHARGING
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 163H NA, 16H NA, 24H, 30/30, 3116, 3126B, 3176C, 3196, 3306C, 330B L, 3406B, 3406C, 3406E, 3408, 34...
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 163H NA, 16H NA, 24H, 30/30, 3116, 3126B, 3176C, 3196, 3306C, 330B L, 3406B, 3406C, 3406E, 3408, 34...
2155568
ALTERNATOR GP-CHARGING
3116, 3406B, 3406C, 3412E, 3508B, 3512B, 3516B, 3516C, 583T, 587T, C-12, C11, C13, C15, C18, C27, C32, CX31-C13I, CX31-C15I, CX35-P800, D6R II, D6R III, D7R II, D8T, D9R, TH35-C11I, TH35-C13I, TH35-C1...
3116, 3406B, 3406C, 3412E, 3508B, 3512B, 3516B, 3516C, 583T, 587T, C-12, C11, C13, C15, C18, C27, C32, CX31-C13I, CX31-C15I, CX35-P800, D6R II, D6R III, D7R II, D8T, D9R, TH35-C11I, TH35-C13I, TH35-C1...
1855294
ALTERNATOR GP-CHARGING
3126B, 322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330C, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406E, 34...
3126B, 322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330C, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406E, 34...
2047449
ALTERNATOR GP-CHARGING
836G, D6R II, D7R II, D8R II, D9R
836G, D6R II, D7R II, D8R II, D9R
1978820
ALTERNATOR GP-CHARGING
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 1390, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H NA, 160H ES, 160H NA, 160K, 163H NA, 16H NA, 22...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 1390, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H NA, 160H ES, 160H NA, 160K, 163H NA, 16H NA, 22...
3E7577
ALTERNATOR GP-CHARGING
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 3114, 3126B, 3176B, 3176C, 3196, 3306, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412...
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 3114, 3126B, 3176B, 3176C, 3196, 3306, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412...
2008277
ALTERNATOR GP-CHARGING
3126B, 3512, 834G, 988G, AD55, AP-1055D, BG-2455D, BG-260D, C32, D11R, D6R II, D7R II, D9R, G3612, G3616, TH48-E70
3126B, 3512, 834G, 988G, AD55, AP-1055D, BG-2455D, BG-260D, C32, D11R, D6R II, D7R II, D9R, G3612, G3616, TH48-E70
3055530
ALTERNATOR GP-CHARGING
3512, 988G, AP-1055D, BG-2455D, BG-260D, C32, D7R II, D9R
3512, 988G, AP-1055D, BG-2455D, BG-260D, C32, D7R II, D9R
2490313
ALTERNATOR GP-CHARGING
120M, 12M, 140M, 160M, 24H, 24M, 583T, 587T, 924H, 924HZ, 928HZ, C9, D6R, D6R III, D6R STD, D6T, D7R II, D7R XR, D8R, D8T, PL83, PL87
120M, 12M, 140M, 160M, 24H, 24M, 583T, 587T, 924H, 924HZ, 928HZ, C9, D6R, D6R III, D6R STD, D6T, D7R II, D7R XR, D8R, D8T, PL83, PL87
9S2563
ALTERNATOR GROUP
120, 12F, 140, 14E, 518, 561C, 920, 930, D5, D6C
120, 12F, 140, 14E, 518, 561C, 920, 930, D5, D6C
3N1383
ALTERNATOR ASSEMBLY
3304, 3306, G3306
3304, 3306, G3306
2667224
ALTERNATOR GP-CHARGING
3126, 3126B, 3406B, C-15, C12, C18, C7, C9
3126, 3126B, 3406B, C-15, C12, C18, C7, C9
1P7773
ALTERNATOR GROUP
966C, 977K
966C, 977K
3079902
ALTERNATOR GP-CHARGING
CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E
CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E
1123454
ALTERNATOR GP-CHARGING
G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B
G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B
1408968
ALTERNATOR GP-CHARGING
824G, 825G, 980G
824G, 825G, 980G
1663974
ALTERNATOR GP-CHARGING
3126B, C7
3126B, C7
8L5410
ALTERNATOR ASSEMBLY
3145, 3150, 3160, 3304, 3306, G3306
3145, 3150, 3160, 3304, 3306, G3306
8L5412
ALTERNATOR ASSEMBLY
3304, 3306, G3306
3304, 3306, G3306
5S6698
ALTERNATOR GP-CHARGING
3406, 3406B, 3408, 3412, 641, D346, D348, D349, D8H, D9G
3406, 3406B, 3408, 3412, 641, D346, D348, D349, D8H, D9G
2Y2936
ALTERNATOR GP-CHARGING
225, 3304, 3306, 930, 930R, 966C, 966R, D4D, D4E, D6C, D6D
225, 3304, 3306, 930, 930R, 966C, 966R, D4D, D4E, D6C, D6D