2168352 ALTERNATOR GP-CHARGING Caterpillar parts
G3520C
Rating:
Alternative (cross code) number:
CA2168352
216-8352
2168352
CA2168352
216-8352
2168352
GENERATOR SET,
Compatible equipment models: 2168352:
Caterpillar SIS machinery equipment:
Information:
If a fault condition exists for the entire duration of inducement level 2, the strategy advances to inducement level 3. Inducement level 3 has the same actions for all categories. The check engine lamp and the emissions malfunction indicator lamp will flash at a fast rate. A red stop lamp will illuminate solid. The engine will have a 100% derate and be limited to 1000 rpm or low idle, whichever is greater. If the final inducement action in Cat® ET is set to "Idle Down", then engine will continue to idle at derated condition. If set to "Shutdown" , engine will shut down after 5 minutes. A key cycle will allow safe harbor mode to initiate. Safe harbor is only allowed once. After safe harbor, the engine will be in level 3 final inducement. If set to "Shutdown", the engine may be restarted, but will only run for 5 minutes at derated condition before shutting down again. This action will continue until the issue is resolved.Note: Contact your Cat dealer for repairs if a fault occurs.Operator Inducement Emergency Override for Cat Engines Equipped with Selective Catalytic Reduction Systems (If Equipped)
Note: The inducement emergency override will only be allowed on a select number of engines that may be used in emergency situations. Contact your Cat dealer to find out if your engine is allowed to have this feature.The operator Inducement emergency override can only be enabled using Caterpillar supplied passwords. The feature is disabled by default. The feature will be enabled at the factory if allowed. If the customer wants the feature enabled after delivery of engine, customers need to contact a Cat dealer. Operator Inducement emergency override is regulated by the Environmental Protection Agency (EPA) and European Union (EU). Operator inducement emergency override is only supported in the United States. Operator inducement emergency override is not supported in Europe, and not allowed to be used in Japan. For detailed information on activating, deactivating, or resetting override, contact your Cat dealer. Before you attempt the procedures documented below, make sure that you have read and understand all information in this document.The United States EPA requires the limiting of engine speed and/or power (derate) in certain conditions, to help ensure proper functioning of the engines emission control system. The EPA allows the temporary disabling of these limits (restoration of full engine speed and power capability) during a qualified emergency situation. The EPA defines a qualified emergency situation as a significant direct or indirect risk to human life. Below are examples of direct versus indirect risks.Direct - An emission control condition that inhibits performance of an engine being used to rescue a person from life-threatening situation.Indirect - An emission control condition that inhibits performance of an engine used to provide electrical power to a data center that routes 911 emergency response communications.The emissions-related derate can be disabled for up to 120 hours of engine operation. The temporary disabling of emissions-related derate is referred to as "Operator Inducement Emergency Override" and must
Note: The inducement emergency override will only be allowed on a select number of engines that may be used in emergency situations. Contact your Cat dealer to find out if your engine is allowed to have this feature.The operator Inducement emergency override can only be enabled using Caterpillar supplied passwords. The feature is disabled by default. The feature will be enabled at the factory if allowed. If the customer wants the feature enabled after delivery of engine, customers need to contact a Cat dealer. Operator Inducement emergency override is regulated by the Environmental Protection Agency (EPA) and European Union (EU). Operator inducement emergency override is only supported in the United States. Operator inducement emergency override is not supported in Europe, and not allowed to be used in Japan. For detailed information on activating, deactivating, or resetting override, contact your Cat dealer. Before you attempt the procedures documented below, make sure that you have read and understand all information in this document.The United States EPA requires the limiting of engine speed and/or power (derate) in certain conditions, to help ensure proper functioning of the engines emission control system. The EPA allows the temporary disabling of these limits (restoration of full engine speed and power capability) during a qualified emergency situation. The EPA defines a qualified emergency situation as a significant direct or indirect risk to human life. Below are examples of direct versus indirect risks.Direct - An emission control condition that inhibits performance of an engine being used to rescue a person from life-threatening situation.Indirect - An emission control condition that inhibits performance of an engine used to provide electrical power to a data center that routes 911 emergency response communications.The emissions-related derate can be disabled for up to 120 hours of engine operation. The temporary disabling of emissions-related derate is referred to as "Operator Inducement Emergency Override" and must
Parts alternator Caterpillar catalog:
4N3986
ALTERNATOR GP-CHARGING
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 35...
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 35...
2667227
ALTERNATOR GP-CHARGING
3126, 3176B, 3176C, 3196, 3306, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C11, C...
3126, 3176B, 3176C, 3196, 3306, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C11, C...
3315717
ALTERNATOR GP-CHARGING
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C-...
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C-...
3331184
ALTERNATOR GP-CHARGING
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 35...
3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 35...
6R0070
ALTERNATOR GP-CHARGING
AP-1000, AP-1050
AP-1000, AP-1050
1904174
ALTERNATOR GP-CHARGING
769C, 769D, 771D
769C, 769D, 771D
3E8827
ALTERNATOR GP-CHARGING
AP-1000, AP-1050
AP-1000, AP-1050
4N8128
ALTERNATOR MOUNTING GROUP
D353C, G353D
D353C, G353D