Information:
Illustration 1 g00696021
Schematic of the Impeller Clutch Solenoid
This diagnostic code is associated with the Impeller Clutch Solenoid. The FMI 05 means that the ECM has determined that the current of the solenoid is below normal. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0678 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, the impeller clutch will not engage. The controlled throttle shifting function is always active. The function of the reduced rimpull is inoperable.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact Contact A (wire H724-YL) (wire H724-YL(Yellow)) to contact Contact B (wire 975-WH) (wire 975-WH(White)).
Observe the status of the CID 0678 FMI 05. Expected Result:The CID 0678 FMI 05 remains active. The FMI has not changed and the "05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-19 (wire H724-YL(Yellow)) to contact J1-7, J2-3 (wire 975-WH(White)). Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire H724-YL(Yellow) or in wire 975-WH(White) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0678 FMI 05. Expected Result:The CID 0678 FMI 05 is active. Results:
YES - The CID 0678 FMI 05 is active. The diagnostic code has not been corrected. The
Parts alternator Caterpillar catalog:
2Z0974
ALTERNATOR GP
Caterpillar
Caterpillar
2Y8969
ALTERNATOR G
Caterpillar
Caterpillar
2Y8967
ALTERNATOR G
Caterpillar
Caterpillar
2Y8943
ALTERNATOR GP
Caterpillar
Caterpillar
2Y7775
ALTERNATOR G
Caterpillar
Caterpillar
2Y2964
ALTERNATOR G
Caterpillar
Caterpillar
3042624
ALTERNATOR
Caterpillar
Caterpillar
3034891
ALTERNATOR
Caterpillar
Caterpillar
3015159
ALTERNATOR GP
Caterpillar
Caterpillar
3001827
ALTERNATOR GP
Caterpillar
Caterpillar
2Z9716
ALTERNATOR GP
Caterpillar
Caterpillar
2Z9488
ALTERNATOR AR
Caterpillar
Caterpillar