4316996 ALTERNATOR GP-CHARGING Caterpillar parts
C7.1
Rating:
Alternative (cross code) number:
CA4316996
431-6996
4316996
CA4316996
431-6996
4316996
INDUSTRIAL ENGINE,
Compatible equipment models: 4316996:
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Information:
The event code, 3576-15 for generator to utility transfer failure that is high - least severe (1) will become active when both of the following occur:
The system is attempting to transfer to utility power.
The "generator to utility transfer failure warning event threshold" timer expires before the transfer is successful.The event threshold set point is used to configure the time the system is allowed to attempt a transfer from generator to utility before the system stops and transfers back to generator power. The timer starts the moment the generator breaker is opened and stops when the utility breaker is read back as "closed". This set point will determine the amount of time the bus will be unpowered in the event that a transfer to utility power fails. The event must be reset once the event becomes active. When the event is active, the system will not attempt to transfer to utility until the event is reset.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "generator to utility transfer failure" warning event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground between the EMCP relay output. The EMCP relay output is designated for utility breaker control to the utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and Utility Breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there is an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure the battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring between the EMCP and breaker connections.Results:
- STOP
The system is attempting to transfer to utility power.
The "generator to utility transfer failure warning event threshold" timer expires before the transfer is successful.The event threshold set point is used to configure the time the system is allowed to attempt a transfer from generator to utility before the system stops and transfers back to generator power. The timer starts the moment the generator breaker is opened and stops when the utility breaker is read back as "closed". This set point will determine the amount of time the bus will be unpowered in the event that a transfer to utility power fails. The event must be reset once the event becomes active. When the event is active, the system will not attempt to transfer to utility until the event is reset.
View active and logged diagnostic codes to determine if there are any other diagnostics that may indicate a problem with the system which may lead to a transfer failure.
Verify EMCP set point for "generator to utility transfer failure" warning event timer limits. Ensure that the timer is set to the appropriate time allotted to complete system transfer.
Wiring: Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground between the EMCP relay output. The EMCP relay output is designated for utility breaker control to the utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and Utility Breaker.
Measure the resistance of the wiring between the designated relay or digital output and the utility breaker or utility breaker control device. If more than 10 ohms of resistance is found, there is an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure the battery voltage at the EMCP relay or digital output pin, and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring between the EMCP and breaker connections.Results:
- STOP
Parts alternator Caterpillar catalog:
2721889
ALTERNATOR GP-CHARGING
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M 2, 160M 3, 160M 3 AWD, 16M, 3512C, 725C, 730C, 735B, 740B, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F X...
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M 2, 160M 3, 160M 3 AWD, 16M, 3512C, 725C, 730C, 735B, 740B, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F X...
2267683
ALTERNATOR GP-CHARGING
140H, 143H, 14H, 160H, 163H, 16H, 2384C, 2470C, 2484C, 2570C, 2670C, 2864C, 374F L, 390F L, 553C, 559C, 563C, 573C, 579C, 586C, 770G, 772G, 773F, 775F, 777C, 777D, 777F, 844H, 953D, 963D, 990H, AD55B,...
140H, 143H, 14H, 160H, 163H, 16H, 2384C, 2470C, 2484C, 2570C, 2670C, 2864C, 374F L, 390F L, 553C, 559C, 563C, 573C, 579C, 586C, 770G, 772G, 773F, 775F, 777C, 777D, 777F, 844H, 953D, 963D, 990H, AD55B,...
3500619
ALTERNATOR GP-CHARGING
C6.6, C7.1
C6.6, C7.1
3218902
ALTERNATOR
C4.4, C4.4XQ100, C4.4XQ80, C7.1
C4.4, C4.4XQ100, C4.4XQ80, C7.1
3466147
ALTERNATOR GP-CHARGING
C13, C7.1, C9.3, CX31-C13I
C13, C7.1, C9.3, CX31-C13I
3218931
ALTERNATOR
C4.4, C7.1
C4.4, C7.1
3218932
ALTERNATOR
312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, C4.4, C7.1
312E, 312E L, 314E CR, 314E LCR, 316E L, 318E L, C4.4, C7.1
3218940
ALTERNATOR
BG1000E, BG1055E, C6.6, C7.1, D6N LGP, D6N OEM
BG1000E, BG1055E, C6.6, C7.1, D6N LGP, D6N OEM
2301584
ALTERNATOR GP-CHARGING
834G, 836G, 988G
834G, 836G, 988G
3501457
ALTERNATOR GP-CHARGING
C4.4, C4.4XQ100, C4.4XQ80
C4.4, C4.4XQ100, C4.4XQ80
2625046
ALTERNATOR GP-CHARGING
824H, 825H, 834H, 988H
824H, 825H, 834H, 988H
4308211
ALTERNATOR GP-CHARGING
793F, 793F CMD, 793F OEM
793F, 793F CMD, 793F OEM
2128409
ALTERNATOR GP-CHARGING
980G II
980G II
3753358
ALTERNATOR GP-CHARGING
D6T LGP, D6T LGPPAT
D6T LGP, D6T LGPPAT
2370027
ALTERNATOR GP-CHARGING
3054C, 3054E, 416D, 420D, 424D, 428D, 430D, 432D, 442D
3054C, 3054E, 416D, 420D, 424D, 428D, 430D, 432D, 442D
3N7608
ALTERNATOR MOUNTING GROUP
D346, D348, D349
D346, D348, D349