ALTERNATOR AS 4811507 - Caterpillar



4811507 ALTERNATOR AS Caterpillar parts
Rating:
16
Alternative (cross code) number:
CA4811507
481-1507
4811507
Caterpillar 4811507 ALTERNATOR AS
Weight: 17 pounds 7 kg.

Buy ALTERNATOR AS 4811507 Caterpillar genuine, new aftermarket tractor parts with delivery

Compare Prices:

As an associate, we earn commssions on qualifying purchases through the links below
$64.08

16 Apr 2025
6.5[2.93] pounds
Amazon.com
Global Parts Distributors - 94-95 S10 (4811507)
GDP 4811507 || 94-95 S10 || Meets or exceeds OEM Specifications
$58.28

09 Aug 2024
6.5[2.93] Pounds
Amazon.com
Global Parts Distributors - 94-95 S10 (4811507)
GDP 4811507 || 94-95 S10 || Meets or exceeds OEM Specifications
$50.78
 

28 Feb 2022
1.0[0.45] Pounds
Amazon.com
Global Parts Distributors - 94-95 S10 (4811507)
GDP 4811507 || 94-95 S10 || Meets or exceeds OEM Specifications
Number on catalog scheme: 3
  For full view, you need register

Caterpillar parts catalog:

Caterpillar parts catalog
C7.1 Marine Commercial Prop Engine GJN00001-UP
C7.1 Marine Propulsion Engine JEZ00001-UP


Information:


Illustration 1 g03885585
Left Implement Pedal Position Sensor Schematic
This diagnostic code is associated with the Left Implement Pedal Position Sensor. The FMI 04 means that the ECM has determined that the voltage of the circuit for the position sensor is below normal. The Left Implement Pedal position control has an output frequency of approximately 500 Hz. The duty cycle of the signal changes as the Left Implement Pedal position is changed. The duty cycle increases as the Left Implement Pedal is depressed. The Left Implement Pedal values are dependent on the Left Implement Pedal linkage. Valid values range from 5% to 95% duty cycle.The possible causes of this diagnostic code are listed below:
Improperly adjusted Left Implement Pedal pedal linkage.
The signal circuit for the sensor is shorted to ground.
The sensor has failed.
The ECM has failed. The ECM is unlikely to fail.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 5002 FMI 04 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code will generate a level 2 warning. Electronic Ant-Stall will be disabled and the Hystat transmission will be limited to low speed.Test Step 1. Check The Output Of The Sensor
At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the signal wire (contact C).
At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the ground wire (contact B).
Turn the key start switch to the ON position.
Measure the duty cycle of the signal. The valid sensor range is 5% duty cycle to 95% duty cycle. This fault occurs for <5% duty cycle. Expected Result:The duty cycle is less than 5% for the whole range of the Left Implement Pedal.Results:
OK - The duty cycle is less than 5% for the whole range of the Left Implement Pedal. Proceed to Test Step 2.
NOT OK - The signal from the sensor is only invalid for part of the Left Implement Pedal range.Repair: The sensor is not adjusted correctly. Adjust the Left Implement Pedal linkage so the sensor signal is valid through the entire range.STOPTest Step 2. Check The Sensor
The key start switch remains in the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from

Parts alternator Caterpillar catalog: