5W2679 ALTERNATOR G Caterpillar parts
Rating:
Alternative (cross code) number:
CA5W2679
5W-2679
5W2679
CA5W2679
5W-2679
5W2679
Weight: 8 pounds 3 kg.
Information:
Hydraulic Activation Control Valve
Illustration 1 g00869852
Pilot oil manifold (1) Pilot oil manifold (2) Solenoid valve (hydraulic activation)
Illustration 2 g00869860
Inside cab (3) Hydraulic activation control lever (LOCKED position)
Illustration 3 g00869863
Inside cab (3) Hydraulic activation control lever (UNLOCKED position)
Illustration 4 g00869857
Hydraulic activation control lever (3) Hydraulic activation control lever (4) Limit switch (5) Plunger When hydraulic activation control lever (3) is placed in the LOCKED position, hydraulic activation solenoid valve (3) closes in order to block oil supply from the pilot pump to the pilot control valves. All hydraulic controls are blocked. No operation of the cylinders and the motors can be made by the activation of the hydraulic controls.Hydraulic activation control lever (3) contains limit switch (4) and plunger (5). When plunger (5) on limit switch (4) is pushed, an electrical signal is sent to solenoid valve (2) .The limit switch allows the engine start switch to operate only when hydraulic activation control lever (3) is placed in the LOCKED position. This prevents unexpected operation of the machine or the implement.When hydraulic activation control lever (3) is placed in the UNLOCKED position, hydraulic activation solenoid valve (2) is energized by an electrical signal from limit switch (4) in order to allow pilot oil to flow to the pilot control valves.
Illustration 5 g00755306
Pilot manifold (hydraulic activation control valve) (7) Passage (11) Passage (12) Spring (13) Spool (14) Passage (15) Spring (16) Spool (17) Passage (18) Passage (19) Solenoid valve (20) LineWhen hydraulic activation control valve (3) is placed in the UNLOCKED position, solenoid valve (19) is energized in order to move spool (16) to the right against the force of spring (15). This allows passage (18) to open. Pilot pressure oil flows through passage (7) and passage (18) to passage (17). The pressure oil acts against spool (13). Spool (13) shifts to the right against the force of spring (12). Passage (14) opens. Pilot pressure oil is sent to the pilot control valves through passage (11) and line (20). Limit switch (4) is turned ON as plunger (5) is pushed down by lever (3).
Illustration 6 g00755318
Pilot manifold (hydraulic activation control valve) (7) Passage (11) Passage (12) Spring (13) Spool (14) Passage (15) Spring (16) Spool (17) Passage (18) Passage (19) Solenoid valve (20) Line (21) Passage (22) PassageWhen hydraulic activation control lever (3) is in the LOCKED position, solenoid valve (19) is de-energized. Spool (16) returns to the left by the force of spring (15). Passage (22) opens. Oil in passage (17) drains and passage (18) closes. When the flow of pilot oil is blocked to passage (17), spool (13) is returned to the left by the force of spring (12). Passage (21) opens and passage (14) closes. Passage (7) and passage (11) are closed. Pilot oil supply to line (20) is stopped. Pilot oil supply to the pilot control valves (joysticks and travel levers/pedals) is blocked. The cylinders and the motors can not be activated.With the hydraulic activation control lever (3) in the LOCKED position, limit switch (4) will turn OFF. Plunger (5) will
Illustration 1 g00869852
Pilot oil manifold (1) Pilot oil manifold (2) Solenoid valve (hydraulic activation)
Illustration 2 g00869860
Inside cab (3) Hydraulic activation control lever (LOCKED position)
Illustration 3 g00869863
Inside cab (3) Hydraulic activation control lever (UNLOCKED position)
Illustration 4 g00869857
Hydraulic activation control lever (3) Hydraulic activation control lever (4) Limit switch (5) Plunger When hydraulic activation control lever (3) is placed in the LOCKED position, hydraulic activation solenoid valve (3) closes in order to block oil supply from the pilot pump to the pilot control valves. All hydraulic controls are blocked. No operation of the cylinders and the motors can be made by the activation of the hydraulic controls.Hydraulic activation control lever (3) contains limit switch (4) and plunger (5). When plunger (5) on limit switch (4) is pushed, an electrical signal is sent to solenoid valve (2) .The limit switch allows the engine start switch to operate only when hydraulic activation control lever (3) is placed in the LOCKED position. This prevents unexpected operation of the machine or the implement.When hydraulic activation control lever (3) is placed in the UNLOCKED position, hydraulic activation solenoid valve (2) is energized by an electrical signal from limit switch (4) in order to allow pilot oil to flow to the pilot control valves.
Illustration 5 g00755306
Pilot manifold (hydraulic activation control valve) (7) Passage (11) Passage (12) Spring (13) Spool (14) Passage (15) Spring (16) Spool (17) Passage (18) Passage (19) Solenoid valve (20) LineWhen hydraulic activation control valve (3) is placed in the UNLOCKED position, solenoid valve (19) is energized in order to move spool (16) to the right against the force of spring (15). This allows passage (18) to open. Pilot pressure oil flows through passage (7) and passage (18) to passage (17). The pressure oil acts against spool (13). Spool (13) shifts to the right against the force of spring (12). Passage (14) opens. Pilot pressure oil is sent to the pilot control valves through passage (11) and line (20). Limit switch (4) is turned ON as plunger (5) is pushed down by lever (3).
Illustration 6 g00755318
Pilot manifold (hydraulic activation control valve) (7) Passage (11) Passage (12) Spring (13) Spool (14) Passage (15) Spring (16) Spool (17) Passage (18) Passage (19) Solenoid valve (20) Line (21) Passage (22) PassageWhen hydraulic activation control lever (3) is in the LOCKED position, solenoid valve (19) is de-energized. Spool (16) returns to the left by the force of spring (15). Passage (22) opens. Oil in passage (17) drains and passage (18) closes. When the flow of pilot oil is blocked to passage (17), spool (13) is returned to the left by the force of spring (12). Passage (21) opens and passage (14) closes. Passage (7) and passage (11) are closed. Pilot oil supply to line (20) is stopped. Pilot oil supply to the pilot control valves (joysticks and travel levers/pedals) is blocked. The cylinders and the motors can not be activated.With the hydraulic activation control lever (3) in the LOCKED position, limit switch (4) will turn OFF. Plunger (5) will
Parts alternator Caterpillar catalog:
5S0317
ALTERNATOR G.
Caterpillar
Caterpillar
5R9073
ALTERNATOR GP
Caterpillar
Caterpillar
5R7391
ALTERNATOR G-
Caterpillar
Caterpillar
5R7090
ALTERNATOR G
Caterpillar
Caterpillar
5R4665
ALTERNATOR G
Caterpillar
Caterpillar
5R4053
ALTERNATOR G
Caterpillar
Caterpillar
6L7567
ALTERNATOR G.
Caterpillar
Caterpillar
6I1855
ALTERNATOR GP
Caterpillar
Caterpillar
6A9556
ALTERNATOR
Caterpillar
Caterpillar
5Z9866
ALTERNATOR GP-
Caterpillar
Caterpillar
5Z4710
ALTERNATOR-G
Caterpillar
Caterpillar
5Y0940
ALTERNATOR GP
Caterpillar
Caterpillar