Illustration 1 g01593275
Schematic for the Implement Pilot Pressure Supply Solenoid
This diagnostic code is associated with the Implement Pilot Pressure Supply Solenoid. The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit. The possible causes for this diagnostic code are listed:
The internal windings for the solenoid have low impedance.
The internal windings for the solenoid are shorted.
The signal circuit from the ECM to the solenoid is shorted to ground.System Response:The machine response is listed:
The implement features will not operate.
The pilot on/off solenoid valve is off.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0358 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 0358 FMI 06 changes to CID 0358 FMI 05 when the solenoid is disconnected.Results:
YES - CID 0358 FMI 06 changes to CID 0358 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - CID 0358 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J1-12 (wire H717-BR(Brown)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-12 (wire H717-BR(Brown)) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0358 FMI 06. Expected Result:The CID 0358 FMI 06 is active. Results:
YES - The CID 0358 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, the ECM may have
Caterpillar parts catalog:
Parts angle Caterpillar catalog:
5S0748
ANGLE ASSEM. (L.H.)
D7F, D7G
D7F, D7G
9S7201
ANGLE ASSEM. (R.H.)
D7F, D7G
D7F, D7G
1P0136
ANGLE
D7F, D7G
D7F, D7G
6P6477
ANGLE
D7G
D7G
6P6475
ANGLE
D7G
D7G
7S1488
ANGLE
D7G
D7G
3Y6773
ANGLE
D7G
D7G
9P3964
ANGLE
D10
D10
8P7183
ANGLE
D8K
D8K
3T4484
ANGLE
D7G
D7G
6T1895
ANGLE AS
D8L
D8L
4W0533
ANGLE AS
D8L
D8L
9V1813
ANGLE AS
834B
834B
9V1421
ANGLE ASSEM.
834B
834B
9P9898
ANGLE
D8L
D8L