3C8435 ARM A WIPR Caterpillar parts
Rating:
Alternative (cross code) number:
CA3C8435
3C-8435
3C8435
CA3C8435
3C-8435
3C8435
Weight: 0.30 pounds 0 kg.
Information:
Illustration 1 g01189249
Schematic of the Solenoid Valve (Lockup Clutch)
This diagnostic code is recorded when the ECM reads the current of the solenoid as being above normal.The possible causes are listed:
A wire is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely.Note: Ensure that CID 0709 FMI 06 for the solenoid is active. Note: The following procedure can create numerous related diagnostic codes. When all harnesses are reconnected, the related diagnostic codes will be shown as being not active. Clear all related diagnostic codes after this procedure is completed.System Response:The transmission does not shift to the highest gears because the lockup solenoid is NEVER ON. The power of the machine is reduced and the fuel consumption will increase.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. DO NOT start the engine.
Disconnect the machine harness from the solenoid.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 705-PK(Pink)) to contact 2 (wire K972-BR(Brown)).
Observe the status of the diagnostic code. Expected Result:The diagnostic code is active. Then, the diagnostic code is NOT active as the jumper wire is installed and removed. Results:
YES - The circuit is correct. The solenoid has failed.Repair: Repeat this test "CHECK THE SOLENOID" in order to verify that the solenoid has failed. Replace the solenoid.STOP
NO - The diagnostic code remains active. Proceed to test step 2.Test Step 2. CHECK THE SOLENOID CIRCUIT FOR A SHORT TO GROUND.
The machine harness remains disconnected from the solenoid.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the J1 and J2 machine harness connector from the ECM.
At the J1 machine harness connector, measure the resistance from the solenoid contact J1-62 (wire 705-PK(Pink)) to all possible sources of ground. The possible sources of ground are contacts: J1-3, J1-5, J1-7, J1-13, J1-20, J1-23, J1-57, J1-60, J1-70, J2-22, J2-63 and frame ground. Expected Result:Each resistance measurement should be greater than 5000 ohms.Results:
YES - The machine harness is correct. Proceed to test step 3.
NO - There is an short in the machine harness.Repair: The short is between the wire for the solenoid signal and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all inactive diagnostic codes.
Operate the machine.
Stop the machine and set the transmission control to the PARK position.
Check if the diagnostic code for the solenoid is active. Expected Result:The diagnostic code is NO longer active. Results:
YES - The diagnostic code is NO longer active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The diagnostic code has not been corrected.Repair: It is