AVSPARE.COM
parts catalog

ARM-BLADE LIFT 8X3613 - Caterpillar


8X3613 ARM-BLADE LIFT Caterpillar parts
Rating:
24
Alternative (cross code) number:
CA8X3613
8X-3613
8X3613
Caterpillar 8X3613 ARM-BLADE LIFT
Weight: 1 pounds 0 kg.

Buy ARM-BLADE LIFT 8X3613 Caterpillar genuine, new aftermarket tractor parts with delivery

  For full view, you need register

Information:


Illustration 1 g00687633
Schematic of Transmission Modulating Solenoid Valve (No. 4)This diagnostic code is recorded when the power train ECM detects an incomplete electrical path. The electrical path from the ECM to the solenoid back to the ECM is incomplete.Possible causes of this diagnostic code are listed:
The harness has failed.
The solenoid is disconnected or there is an open circuit.System Response:The machine response is listed:
Gears that use solenoids that have diagnostic codes are not available.Note: This procedure can cause new diagnostic codes to be recorded. Ignore these created diagnostic codes. Complete the following procedure. Then clear the created diagnostic codes.Note: Ensure that the diagnostic code is active and that the diagnostic code indicator is active.Test Step 1. Check the Solenoid.
Turn the battery disconnect switch and the key start switch to the ON position.
Disconnect the solenoid valve from the harness.
Observe the ON/OFF status of the diagnostic code indicator.
At the harness connector for the solenoid valve, place a jumper from contact 1 to contact 2.Expected Result:The diagnostic code indicator should remain active.Results:
YES - The diagnostic code indicator remains active.Repair: The harness or the power train ECM has failed. Proceed to test step 2.
NO - The diagnostic code indicator changes from the active mode to the inactive mode.Repair: The solenoid valve or the harness has failed. Repeat Step 1 in order to verify that the solenoid valve has failed. Repair the solenoid valve and/or the harness or replace the solenoid valve and/or the harness. Stop.Test Step 2. Check for an Open Harness Circuit.
Turn the disconnect switch to the OFF position.
Remove the jumper that was installed in the previous test step.
Reconnect the solenoid valve to the machine harness.
Disconnect the harness from the ECM.
At the harness connector for the power train ECM, measure the resistance between wire 975-WH and the contact for the failed solenoid valve circuit.Expected Result: The resistance should be between 6 to 14 Ohms.Results:
YES - The resistance is between 6 to 14 ohms.Repair: It is unlikely that the power train ECM has failed. Perform these test steps again. Also ensure that the diagnostic code indicator is active for this diagnostic code. If the cause is not found, replace the power train ECM. Stop.
NO - The resistance is greater than 5000 Ohms.Repair: The harness circuit has failed. Wire 975-WH is open in the harness between the ECM and the solenoid valve, or the wire to the solenoid valve is open. Repair the harness or replace the harness. For additional information on replacing the power train ECM, refer to Testing and Adjusting, "Electronic Control Module (Power Train ) - Replace". Stop.


Parts arm Caterpillar catalog:

8Z0607 ARM
Caterpillar
8Z0606 ARM
Caterpillar
8X9388 ARM
Caterpillar
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.