Information:
Starting the Fault Diagnosis
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Caterpillar parts catalog:
Parts axle Caterpillar catalog:
2142567
AXLE GP
AD30
AD30
2090970
AXLE AR
AD30
AD30
3799798
AXLE AR
AD30
AD30
3799768
AXLE AR-REAR
AD30
AD30
3799769
AXLE AR-REAR
AD30
AD30
3799748
AXLE GP
AD30
AD30
3647095
AXLE AS-REAR
CC34B
CC34B
3647085
AXLE AS-REAR
CC24B
CC24B
1G3360
AXLE
PS-500
PS-500
0848198
AXLE
PS-300, PS-500
PS-300, PS-500
1708317
AXLE
PS-500
PS-500
7R2538
AXLE
PS-300, PS-500
PS-300, PS-500
9X0708
AXLE
CS-323
CS-323
0832606
AXLE
CS-643
CS-643
0848442
AXLE
CS-643
CS-643
0815158
AXLE
CS-643
CS-643
0819442
AXLE
AP-800
AP-800
8C7808
AXLE
AP-1200, AP-800
AP-1200, AP-800