2669707 BAR AS Caterpillar parts
24M
Rating:
Alternative (cross code) number:
CA2669707
266-9707
2669707
CA2669707
266-9707
2669707
Weight: 278 pounds 126 kg.
MOTOR GRADER,
Compatible equipment models: 2669707:
Information:
Trucks With Electronic Monitoring System (EMS)
Note: For 793F trucks, the electrical system for the automatic lubrication is controlled by the Chassis ECM. Refer to Systems Operation, KENR9949, "Electrical System " for control information.
Illustration 1 g00291860
Wiring diagram for the automatic lubrication system
Illustration 2 g00863066
System, components, and lines for trucks with Electronic Monitoring System (EMS)Typical Example (1) Lubrication pump (2) Autolube timer (3) Electric solenoid air valve
Illustration 3 g00291857
(3) Electric solenoid air valveThe electrical system for the automatic lubrication consists of two components. The two components are the autolube timer (2) and the electric solenoid air valve (3) . The timer energizes the solenoid at specific time intervals. The solenoid controls the air line which operates lubrication pump (1) .Ten minutes after the machine has started the timer will turn on the solenoid. The timer keeps the solenoid on for 75 seconds. Then, the timer is shut off. At every 60 minute interval, the timer will turn on the solenoid for 75 seconds. This timing interval continues until the machine is turned off.Trucks With Vital Information Management System (VIMS)
Illustration 4 g00291876
(4) Signal to the VIMS (5) Signal to the VIMS sensor module (6) VIMS sensor moduleThe electrical system that is for the automatic lubrication system has an electric solenoid air valve (3) . At specific intervals, the electric solenoid air valve is energized by the VIMS. The solenoid controls the air line which operates the lubrication pump.Ten minutes after the machine has started the VIMS will turn on the solenoid. The VIMS keeps the solenoid on for 75 seconds. Then, the solenoid is shut off. At every 60 minute interval, the VIMS will turn on the solenoid for 75 seconds. This timing interval continues until the machine is turned off.The time can be adjusted from 5 minutes to 120 minutes and the solenoid ON time can be adjusted from 30 seconds to 120 seconds. The time is only adjustable with the VIMS. Refer to the Service Manual, "Vital Information Management System".
Note: For 793F trucks, the electrical system for the automatic lubrication is controlled by the Chassis ECM. Refer to Systems Operation, KENR9949, "Electrical System " for control information.
Illustration 1 g00291860
Wiring diagram for the automatic lubrication system
Illustration 2 g00863066
System, components, and lines for trucks with Electronic Monitoring System (EMS)Typical Example (1) Lubrication pump (2) Autolube timer (3) Electric solenoid air valve
Illustration 3 g00291857
(3) Electric solenoid air valveThe electrical system for the automatic lubrication consists of two components. The two components are the autolube timer (2) and the electric solenoid air valve (3) . The timer energizes the solenoid at specific time intervals. The solenoid controls the air line which operates lubrication pump (1) .Ten minutes after the machine has started the timer will turn on the solenoid. The timer keeps the solenoid on for 75 seconds. Then, the timer is shut off. At every 60 minute interval, the timer will turn on the solenoid for 75 seconds. This timing interval continues until the machine is turned off.Trucks With Vital Information Management System (VIMS)
Illustration 4 g00291876
(4) Signal to the VIMS (5) Signal to the VIMS sensor module (6) VIMS sensor moduleThe electrical system that is for the automatic lubrication system has an electric solenoid air valve (3) . At specific intervals, the electric solenoid air valve is energized by the VIMS. The solenoid controls the air line which operates the lubrication pump.Ten minutes after the machine has started the VIMS will turn on the solenoid. The VIMS keeps the solenoid on for 75 seconds. Then, the solenoid is shut off. At every 60 minute interval, the VIMS will turn on the solenoid for 75 seconds. This timing interval continues until the machine is turned off.The time can be adjusted from 5 minutes to 120 minutes and the solenoid ON time can be adjusted from 30 seconds to 120 seconds. The time is only adjustable with the VIMS. Refer to the Service Manual, "Vital Information Management System".
Caterpillar parts catalog:
Parts bar Caterpillar catalog:
1716682
BAR
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 143H, 14H, 14H NA, 14M, 160H, 160H ES, 160H...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 143H, 14H, 14H NA, 14M, 160H, 160H ES, 160H...
2K0703
BAR
120K, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA, ...
120K, 120M, 120M 2, 12E, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA, ...
1071097
BAR-CLAMP
24M, CP-563, CS-531C, CS-533, CS-533C, CS-563C, CS-573C, CS-583, CS-583C
24M, CP-563, CS-531C, CS-533, CS-533C, CS-563C, CS-573C, CS-583, CS-583C
2747492
BAR-BUS
24M
24M
3521599
BAR-BUS
24M
24M
3521600
BAR-BUS
24M
24M
3521600
BAR-BUS
24M
24M
3521599
BAR-BUS
24M
24M
2747492
BAR-BUS
24M
24M
2242214
BAR AS
LR18B
LR18B
2242209
BAR AS
LR18B
LR18B
2548127
BAR
T9B
T9B
4363828
BAR AS
16M
16M
3029124
BAR
16M
16M
2641158
BAR AS
16M
16M
3222924
BAR-BUS
16M
16M
2442714
BAR AS
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M
2442713
BAR AS
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M
120M, 120M 2, 12M, 12M 2, 140M, 140M 2, 14M, 160M, 160M 2, 16M