1709959 BARREL AS Caterpillar parts
318B
Rating:
Alternative (cross code) number:
CA1709959
170-9959
1709959
CA1709959
170-9959
1709959
Weight: 6 pounds 2 kg.
EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1709959 Barrel AS-RH (New AFTERMARKET) - G&T Engine Parts
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 7.04 lbs || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 7.04 lbs || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
CTP 1709959 Hydraulic AS-RH Barrel for Model 318B
CTP This is how the flow is generated || During service it is suggested that if pistons are to be replaced all should be changed || As the cylinder block turns the pistons travel in and out of the bore of the block
CTP This is how the flow is generated || During service it is suggested that if pistons are to be replaced all should be changed || As the cylinder block turns the pistons travel in and out of the bore of the block
Compatible equipment models: 1709959:
Information:
LED Indicators
A fault should be immediately serviced. A fault indicator is illuminated when a problem exists. When the PLC has an active fault, find the appropriate procedure in the troubleshooting section.The Processor's Fault Indicators
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.A fault should be immediately serviced. A fault indicator is illuminated when a problem exists. When the PLC has an active fault, find the appropriate procedure in the troubleshooting section.Six LED indicators are on the front of the CPU module. The indicators show the operating status of your processor. The indicators have the labels that are in the following list:"RUN", "FLT", "BATT", "FORCE", "DH+" and "RS232"The "RUN" LED Indicator
When the green LED is illuminated, the processor is in the run mode. When the LED is flashing the processor is transferring a program from the RAM to the memory module. When the LED is extinguished the processor is not in the "RUN" mode.The "FLT" LED Indicator
When the red "FLT" LED is illuminated, there is a fatal error. The CPU has stopped running. When the red "FLT" LED is flashing during powerup, the processor has not been configured correctly. When the red "FLT" LED is flashing the processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The "BATT" LED Indicator
When the red "BATT "LED is illuminated, the battery voltage has fallen below a threshold level or the battery jumper is not connected. When the red LED is off, the battery is functional or the battery jumper is present.The "FORCE" LED Indicator
When the amber "FORCE" LED is flashing or the amber "FORCE" LED is on, the system's performance cannot be guaranteed. The program for the PLC has been modified improperly.The "DH+" LED Indicator
The green "DH+" LED is on when at least 1 "DH+" device is attached.The green "DH+" LED is flashing. There are no active nodes on the network.The red "DH+" LED is flashing. There are duplicate active nodes on the link with the same address."RS232" LED Indicator
The green "RS232" LED is flashing. This indicates that the PLC is communicating with the PC.
Illustration 1 g00562938
The SLC 5/04 Processor
Illustration 2 g00563311
The Processor's LED indicators are off. Refer to Troubleshooting, "System Power".
Illustration 3 g00563312
The Processor's "RUN" LED indicator is off. Turn the keyswitch to the RUN position.
Illustration 4 g00563333
The "Power" LED indicator is on. Refer to Troubleshooting, "Central Processing Unit Fault".
Illustration 5 g00563338
If the "POWER" LED and the "RUN" LED is ON, the system is in normal operation. If illustration 5 is shown, and an error still exists, Refer to Troubleshooting, "System Inoperable".
Illustration 6 g00563342
If the "POWER" LED and "FLT" LED is ON, Refer to Troubleshooting, "Central Processing Communication Error".
Illustration 7 g00593498
If the "POWER" LED is ON and the "FLT" LED is flashing Refer to Troubleshooting, "Central Processing Unit Major Fault".
Illustration 8 g00563349
The "POWER"
A fault should be immediately serviced. A fault indicator is illuminated when a problem exists. When the PLC has an active fault, find the appropriate procedure in the troubleshooting section.The Processor's Fault Indicators
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.A fault should be immediately serviced. A fault indicator is illuminated when a problem exists. When the PLC has an active fault, find the appropriate procedure in the troubleshooting section.Six LED indicators are on the front of the CPU module. The indicators show the operating status of your processor. The indicators have the labels that are in the following list:"RUN", "FLT", "BATT", "FORCE", "DH+" and "RS232"The "RUN" LED Indicator
When the green LED is illuminated, the processor is in the run mode. When the LED is flashing the processor is transferring a program from the RAM to the memory module. When the LED is extinguished the processor is not in the "RUN" mode.The "FLT" LED Indicator
When the red "FLT" LED is illuminated, there is a fatal error. The CPU has stopped running. When the red "FLT" LED is flashing during powerup, the processor has not been configured correctly. When the red "FLT" LED is flashing the processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The "BATT" LED Indicator
When the red "BATT "LED is illuminated, the battery voltage has fallen below a threshold level or the battery jumper is not connected. When the red LED is off, the battery is functional or the battery jumper is present.The "FORCE" LED Indicator
When the amber "FORCE" LED is flashing or the amber "FORCE" LED is on, the system's performance cannot be guaranteed. The program for the PLC has been modified improperly.The "DH+" LED Indicator
The green "DH+" LED is on when at least 1 "DH+" device is attached.The green "DH+" LED is flashing. There are no active nodes on the network.The red "DH+" LED is flashing. There are duplicate active nodes on the link with the same address."RS232" LED Indicator
The green "RS232" LED is flashing. This indicates that the PLC is communicating with the PC.
Illustration 1 g00562938
The SLC 5/04 Processor
Illustration 2 g00563311
The Processor's LED indicators are off. Refer to Troubleshooting, "System Power".
Illustration 3 g00563312
The Processor's "RUN" LED indicator is off. Turn the keyswitch to the RUN position.
Illustration 4 g00563333
The "Power" LED indicator is on. Refer to Troubleshooting, "Central Processing Unit Fault".
Illustration 5 g00563338
If the "POWER" LED and the "RUN" LED is ON, the system is in normal operation. If illustration 5 is shown, and an error still exists, Refer to Troubleshooting, "System Inoperable".
Illustration 6 g00563342
If the "POWER" LED and "FLT" LED is ON, Refer to Troubleshooting, "Central Processing Communication Error".
Illustration 7 g00593498
If the "POWER" LED is ON and the "FLT" LED is flashing Refer to Troubleshooting, "Central Processing Unit Major Fault".
Illustration 8 g00563349
The "POWER"
Caterpillar parts catalog:
Parts barrel Caterpillar catalog:
1232143
BARREL AS
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313B, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315B, 315B L, 315C, 31...
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313B, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315B, 315B L, 315C, 31...
2095991
BARREL AS
318B, 318E L, 319D L, 320C, 320D FM, 320D LRR, 320E L, 320E LN, 320E LRR, 321D LCR, 322B L, 322C, 322C FM, 323D L, 323D LN, 323E L, 324E LN, 325B L, 325C, 325C FM, 330B L
318B, 318E L, 319D L, 320C, 320D FM, 320D LRR, 320E L, 320E LN, 320E LRR, 321D LCR, 322B L, 322C, 322C FM, 323D L, 323D LN, 323E L, 324E LN, 325B L, 325C, 325C FM, 330B L
1709960
BARREL AS
318B
318B
1336777
BARREL AS
311C, 313D2 LGP, 315C, 315D L, 316E L, 318B, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 32...
311C, 313D2 LGP, 315C, 315D L, 316E L, 318B, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 32...
2344629
BARREL AS
318B, 318C, 318E L, 319D, 319D L, 319D LN, 320C, 320C FM, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 322B L, 322C, 3...
318B, 318C, 318E L, 319D, 319D L, 319D LN, 320C, 320C FM, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321C, 321D LCR, 322B L, 322C, 3...
1709960
BARREL AS
318B
318B
2095991
BARREL AS
318B, 318E L, 319D L, 320C, 320D FM, 320D LRR, 320E L, 320E LN, 320E LRR, 321D LCR, 322B L, 322C, 322C FM, 323D L, 323D LN, 323E L, 324E LN, 325B L, 325C, 325C FM, 330B L
318B, 318E L, 319D L, 320C, 320D FM, 320D LRR, 320E L, 320E LN, 320E LRR, 321D LCR, 322B L, 322C, 322C FM, 323D L, 323D LN, 323E L, 324E LN, 325B L, 325C, 325C FM, 330B L
1275975
BARREL AS
311, 311B, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317B LN
311, 311B, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317B LN
1275976
BARREL AS
311, 311B, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317B LN
311, 311B, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317B LN
1232143
BARREL AS
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313B, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315B, 315B L, 315C, 31...
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313B, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315B, 315B L, 315C, 31...
1911393
BARREL-CYLINDER
953D, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, M315, M315C, M316C, M318, M318C, M318C MH, M320, M322C, PL61, PL83, PL87
953D, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, M315, M315C, M316C, M318, M318C, M318C MH, M320, M322C, PL61, PL83, PL87
1799733
BARREL
307B, 307C, 308C
307B, 307C, 308C
1076522
BARREL
307, 307B
307, 307B
1347494
BARREL
313B
313B
1298025
BARREL
312B, 313B
312B, 313B
9T3370
BARREL-CYLINDER
1090, 1190, 1190T, 1290T, 1390, 215B, 225, 2290, 231D, 2390, 2391, 2491, 2590, 322B L, 322C, 322C FM, 324D FM, 324D FM LL, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330C L, 330D FM, 330D ...
1090, 1190, 1190T, 1290T, 1390, 215B, 225, 2290, 231D, 2390, 2391, 2491, 2590, 322B L, 322C, 322C FM, 324D FM, 324D FM LL, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330C L, 330D FM, 330D ...
1570430
BARREL
M312, M313C, M313D, M315, M315C, M315D, M315D 2, M316C, M316D, M317D 2
M312, M313C, M313D, M315, M315C, M315D, M315D 2, M316C, M316D, M317D 2