4F9413 BEARING (.020" U'' SIZE) Caterpillar parts
D315
Rating:
Alternative (cross code) number:
CA4F9413
4F-9413
4F9413
CA4F9413
4F-9413
4F9413
Weight: 0.17 pounds 0 kg.
Information:
ID
45.733
mm
OD
57.175
mm
WIDTH
25.31
mm
MARINE ENGINE,
Compatible equipment models: 4F9413:
Information:
Engine Shutdown Events
VIMS has the ability to stop the engine when any one or more of the following engine shutdown events exist:
Low engine oil level
Low engine oil pressure
Low engine coolant level
High engine coolant temperature
Methane Detection SystemAll the following conditions must also be met before an engine shutdown event will cause VIMS to shut down the engine:
The engine has been running longer than 20 seconds.
The engine must be at low idle or elevated low idle.
The ground speed must be zero.
The parking brake must be in the ON position.The following events will warn the operator before VIMS will shut down the engine:
A warning category 2 will occur when the engine oil level is low and the engine is running. The message center for VIMS will inform the operator of low engine oil level. The message center will also instruct the operator to add oil immediately.
A warning category 3 will occur when the engine oil pressure is low and the engine is running. The message center for VIMS will inform the operator of low engine oil pressure. The message center will also instruct the operator to stop the engine immediately.
A warning category 2 will occur when the engine coolant level is low and the engine is running. The message center for VIMS will inform the operator of a low engine coolant level. The message center will also instruct the operator to add coolant.
A warning category 2 will occur when the engine coolant temperature is high and the engine is running. The message center will inform the operator of high engine coolant temperature. The message center will also instruct the operator to reduce the load on the engine.
A warning category 3 will occur when the methane detection system triggers both visual and audible alarms that trigger at 20% LFL (Lower Flammability Limit) and 50% LFL of methane. The message center for VIMS will inform the operator of methane detection.Operation
If the Methane Detection System is still alarming, the system will not allow the engine to restart.If the engine is stopped, and one or more engine shutdown events is active, VIMS will allow the engine to be started. After the engine is started, the following conditions must exist before VIMS can shut down the engine.
The engine must be at low idle or elevated low idle.
The ground speed must be zero.
The parking brake must be in the ON position.If these conditions exist for 20 seconds after the engine is started, VIMS will ask the Engine Electronic Control Module (Engine ECM) to stop the engine.If the operator uses the accelerator control to increase the engine speed or if the operator places the parking brake control in the OFF position, VIMS will not stop the engine. VIMS assumes that an operator is in control of the machine.If one or more engine shutdown events occurs during machine operation, VIMS will not stop the engine. VIMS will alert the operator of the abnormal machine condition.VIMS will then ask the Engine ECM to shut down the engine when the following
VIMS has the ability to stop the engine when any one or more of the following engine shutdown events exist:
Low engine oil level
Low engine oil pressure
Low engine coolant level
High engine coolant temperature
Methane Detection SystemAll the following conditions must also be met before an engine shutdown event will cause VIMS to shut down the engine:
The engine has been running longer than 20 seconds.
The engine must be at low idle or elevated low idle.
The ground speed must be zero.
The parking brake must be in the ON position.The following events will warn the operator before VIMS will shut down the engine:
A warning category 2 will occur when the engine oil level is low and the engine is running. The message center for VIMS will inform the operator of low engine oil level. The message center will also instruct the operator to add oil immediately.
A warning category 3 will occur when the engine oil pressure is low and the engine is running. The message center for VIMS will inform the operator of low engine oil pressure. The message center will also instruct the operator to stop the engine immediately.
A warning category 2 will occur when the engine coolant level is low and the engine is running. The message center for VIMS will inform the operator of a low engine coolant level. The message center will also instruct the operator to add coolant.
A warning category 2 will occur when the engine coolant temperature is high and the engine is running. The message center will inform the operator of high engine coolant temperature. The message center will also instruct the operator to reduce the load on the engine.
A warning category 3 will occur when the methane detection system triggers both visual and audible alarms that trigger at 20% LFL (Lower Flammability Limit) and 50% LFL of methane. The message center for VIMS will inform the operator of methane detection.Operation
If the Methane Detection System is still alarming, the system will not allow the engine to restart.If the engine is stopped, and one or more engine shutdown events is active, VIMS will allow the engine to be started. After the engine is started, the following conditions must exist before VIMS can shut down the engine.
The engine must be at low idle or elevated low idle.
The ground speed must be zero.
The parking brake must be in the ON position.If these conditions exist for 20 seconds after the engine is started, VIMS will ask the Engine Electronic Control Module (Engine ECM) to stop the engine.If the operator uses the accelerator control to increase the engine speed or if the operator places the parking brake control in the OFF position, VIMS will not stop the engine. VIMS assumes that an operator is in control of the machine.If one or more engine shutdown events occurs during machine operation, VIMS will not stop the engine. VIMS will alert the operator of the abnormal machine condition.VIMS will then ask the Engine ECM to shut down the engine when the following
Caterpillar parts catalog:
Parts bearing Caterpillar catalog:
1H1544
BEARING ASSEMBLY-CRANKSHAFT-FRONT
955C, 977D, D315
955C, 977D, D315
1H1545
BEARING ASSEMBLY-CRANKSHAFT-INTERMEDIATE
955C, 977D, D315
955C, 977D, D315
1H1546
BEARING ASSEMBLY-CRANKSHAFT-CENTER
955C, 977D, D315
955C, 977D, D315
1B4115
BEARING
1674, 1693, 955C, 977D, D315, D326F, D334, D337F, D342, D353C, D379, D397D, G342C, G353D
1674, 1693, 955C, 977D, D315, D326F, D334, D337F, D342, D353C, D379, D397D, G342C, G353D
4B4731
BEARING
772, D315, D337, D348, D353C, D364, D379A, D397D, G398
772, D315, D337, D348, D353C, D364, D379A, D397D, G398
7F5153
BEARING
772, D315, D326F, D337, D342, D342C, D348, D353C, D364, D379A, D397D, G353D, G398
772, D315, D326F, D337, D342, D342C, D348, D353C, D364, D379A, D397D, G353D, G398
1F2362
BEARING
12E, 16, 1673, 1693, 583H, 657, 955C, 977H, 988, D315, D326F, D330A, D342, D342C, D343, D375D, D4D, D8H
12E, 16, 1673, 1693, 583H, 657, 955C, 977H, 988, D315, D326F, D330A, D342, D342C, D343, D375D, D4D, D8H
3B2084
BEARING
955C, 977D, D315
955C, 977D, D315
1B5387
BEARING
120G, 3208, 3406, 3408, 3508, 3512, 3516, 594, 951B, 966C, D315, D326F, D337, D342, D342C, D4D, D5, D9H
120G, 3208, 3406, 3408, 3508, 3512, 3516, 594, 951B, 966C, D315, D326F, D337, D342, D342C, D4D, D5, D9H
9F8580
BEARING (STD.)
955C, 977D, D315
955C, 977D, D315
4F9414
BEARING
955C, D315
955C, D315
6B2730
BEARING ASSEM.
D315, G3508, G3512, G3516
D315, G3508, G3512, G3516
1W7503
BEARING
3508, 3516
3508, 3516
9N5791
BEARING-THRUST
225, 3208, 613B, FB221
225, 3208, 613B, FB221
9N5792
BEARING-MAIN
215, 225, 3208, 613B, 931B, D3, FB221
215, 225, 3208, 613B, 931B, D3, FB221
9N5793
BEARING-MAIN
215, 225, 3208, 613B, 931B, D3, FB221
215, 225, 3208, 613B, 931B, D3, FB221
5F5081
BEARING
D315, D364
D315, D364
8B7622
BEARING
D315
D315
5F2462
BEARING
D315
D315
9B9476
BEARING
977D, D315, D326F, D337, D342, D353C, D397D
977D, D315, D326F, D337, D342, D353C, D397D
4F9417
BEARING
955C, D315
955C, D315