Information:
Operation Description:The data radio is not receiving power.The probable conditions that cause this symptom are in the following list:
Display is not turned "ON".
A fuse is open or a circuit breaker is open.
Failed data radio
Power Jumper
Power Module
Damaged harness or connectorTest Step 1. VERIFY THAT THE DISPLAY WILL TURN ON.
Ensure that the battery disconnect switch and the key start switch are in the ON position.
Turn the display ON.Expected Result:The display turns ON.Results:
OK - The display turns ON. Proceed to Test Step 2.
NOT OK - The display does not turn ON.Repair: Refer to the Troubleshooting section of Service Manual, KENR8980, "Electrical Power Supply (Display)".STOPTest Step 2. VERIFY THAT THE DATA RADIO POWERS UP.
Verify that the power LED on the data radio is illuminated.Expected Result:The power LED on the data radio is illuminated.Results:
OK - The power LED on the data radio is illuminated.Repair: The cause of the problem was Display. The Display was turned Off. Return the machine to service.STOP
NOT OK - The power LED on the GPS receiver(s) is not illuminated. Proceed to Test Step 3.Test Step 3. CHECK THE POWER TO THE GPS RECEIVERS.
Disconnect the harness connectors from the connector for the data radio.
Measure the voltage between pin 1 and pin 2 on the harness connector for the data radio.Expected Result:The measured voltage is approximately machine voltage.Results:
OK - The measured voltage is approximately machine voltage.Repair: The data radio has failed. Replace the failed AccuGrade radio.STOP
NOT OK - The voltage is not approximately machine voltage. Proceed to Test Step 4.Test Step 4. CHECK FUSE OR CIRCUIT BREAKER.
Check the fuse or the circuit breaker.Note: Use the schematic for your machine in order to identify the correct fuse or the circuit breaker.Expected Result:The fuse or the circuit breaker is okay.Results:
OK - The fuse or the circuit breaker is okay. Proceed to Test Step 5.
NOT OK - The fuse or the circuit breaker has failed.Repair: Replace the fuse or the circuit breaker.STOPTest Step 5. CHECK FOR AN OPEN POWER JUMPER IN THE POWER CIRCUIT IN THE HARNESS.
Use the electrical schematic for the machine in order to determine if a power jumper is used.
Disconnect the power jumper.
Place a jumper between pin B and pin C at the harness connector of the Display.
Turn the Display ON.Expected Result:The data radio powers up.Results:
OK - The power jumper has failed.Repair: Replace the power jumper.STOP
NOT OK - The data radio does not power up. The power jumper is not the cause of the failure. Proceed to Test Step 6.Test Step 6. CHECK FOR A SHORTED POWER CIRCUIT IN THE
Display is not turned "ON".
A fuse is open or a circuit breaker is open.
Failed data radio
Power Jumper
Power Module
Damaged harness or connectorTest Step 1. VERIFY THAT THE DISPLAY WILL TURN ON.
Ensure that the battery disconnect switch and the key start switch are in the ON position.
Turn the display ON.Expected Result:The display turns ON.Results:
OK - The display turns ON. Proceed to Test Step 2.
NOT OK - The display does not turn ON.Repair: Refer to the Troubleshooting section of Service Manual, KENR8980, "Electrical Power Supply (Display)".STOPTest Step 2. VERIFY THAT THE DATA RADIO POWERS UP.
Verify that the power LED on the data radio is illuminated.Expected Result:The power LED on the data radio is illuminated.Results:
OK - The power LED on the data radio is illuminated.Repair: The cause of the problem was Display. The Display was turned Off. Return the machine to service.STOP
NOT OK - The power LED on the GPS receiver(s) is not illuminated. Proceed to Test Step 3.Test Step 3. CHECK THE POWER TO THE GPS RECEIVERS.
Disconnect the harness connectors from the connector for the data radio.
Measure the voltage between pin 1 and pin 2 on the harness connector for the data radio.Expected Result:The measured voltage is approximately machine voltage.Results:
OK - The measured voltage is approximately machine voltage.Repair: The data radio has failed. Replace the failed AccuGrade radio.STOP
NOT OK - The voltage is not approximately machine voltage. Proceed to Test Step 4.Test Step 4. CHECK FUSE OR CIRCUIT BREAKER.
Check the fuse or the circuit breaker.Note: Use the schematic for your machine in order to identify the correct fuse or the circuit breaker.Expected Result:The fuse or the circuit breaker is okay.Results:
OK - The fuse or the circuit breaker is okay. Proceed to Test Step 5.
NOT OK - The fuse or the circuit breaker has failed.Repair: Replace the fuse or the circuit breaker.STOPTest Step 5. CHECK FOR AN OPEN POWER JUMPER IN THE POWER CIRCUIT IN THE HARNESS.
Use the electrical schematic for the machine in order to determine if a power jumper is used.
Disconnect the power jumper.
Place a jumper between pin B and pin C at the harness connector of the Display.
Turn the Display ON.Expected Result:The data radio powers up.Results:
OK - The power jumper has failed.Repair: Replace the power jumper.STOP
NOT OK - The data radio does not power up. The power jumper is not the cause of the failure. Proceed to Test Step 6.Test Step 6. CHECK FOR A SHORTED POWER CIRCUIT IN THE
Parts bearing Caterpillar catalog:
8E5291
BEARING A
Caterpillar
Caterpillar
8E5140
BEARING-RLR AS
Caterpillar
Caterpillar
8E1313
BEARING
Caterpillar
Caterpillar
8E0747
BEARING
Caterpillar
Caterpillar
8C9039
BEARING KIT
Caterpillar
Caterpillar
8C9037
BEARING KIT
Caterpillar
Caterpillar
8F1978
BEARING-LH
Caterpillar
Caterpillar
8F1977
BEARING-RH
Caterpillar
Caterpillar
8F0802
BEARING
Caterpillar
Caterpillar
8E9797
BEARING
Caterpillar
Caterpillar
8E7039
BEARING
Caterpillar
Caterpillar
8E5487
BEARING-SLEEVE
Caterpillar
Caterpillar