Information:
T2a - Undesired Electrical System Current - Test (For Machines Equipped With a Main Disconnect Switch)
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Turn off all of the accessories. Turn the keyswitch to the OFF position.
Clamp a 9U-5795 Current Probe or 225-8266 Ammeter Tool Gp around the main ground cable. Clamp the tool with the positive side away from the battery. Reset the probe (zero) before you clamp the probe around the wire. Read the current. Expected Result: The current is below 2 A.Results:
YES - The current is below 2 A. Continue to Step 3.
NO - The current is above 2 A. There is a current draw in the system. Go to Testing and Adjusting, "T5 Alternator Current - Test"
Turn the disconnect switch to the ON position. Connect a multimeter across the disconnect switch terminals. Connect the red lead to the terminal on the frame side. Connect the black lead to the terminal on the battery side. Use the 10A connections in order to avoid damage.
Turn off the disconnect switch and read the current. Expected Result: The current is below .050 amperes (50 mA).Note: The standard acceptable current draw is 50 mA. A current draw above 50 mA usually indicates a problem. However, some large machines with multiple electronic control modules have a higher acceptable limit. Contact a Caterpillar dealer
Parts bearing Caterpillar catalog:
8U9411
BEARING ROLLER
Caterpillar
Caterpillar
8U9410
BEARING ROLLER
Caterpillar
Caterpillar
8U9304
BEARING-SEAL
Caterpillar
Caterpillar
8U9296
BEARING SEAL
Caterpillar
Caterpillar
8U7724
BEARING
Caterpillar
Caterpillar
8U7286
BEARING-ROLLER
Caterpillar
Caterpillar
8W5388
BEARING-SLEEVE
Caterpillar
Caterpillar
8W3983
BEARING
Caterpillar
Caterpillar
8W2871
BEARING-SLEEVE
Caterpillar
Caterpillar
8V8248
BEARING
Caterpillar
Caterpillar
8V5709
BEARING-SLEEVE
Caterpillar
Caterpillar
8V5679
BEARING-SLEEVE
Caterpillar
Caterpillar