3L7540 BELT Caterpillar parts
D342C
Rating:
Alternative (cross code) number:
CA3L7540
3L-7540
3L7540
CA3L7540
3L-7540
3L7540
Weight: 0.40 pounds 0 kg.
INDUSTRIAL ENGINE,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 3L7540 External Engine V-Belt, 15/16" Size, 66.5" Length
CTP For External engine || 15/16" Size || 66.5" Length
CTP For External engine || 15/16" Size || 66.5" Length
CTP 3L7540 External Engine V-Belt, 15/16" Size, 66.5" Length
CTP For External engine || 15/16" Size || 66.5" Length
CTP For External engine || 15/16" Size || 66.5" Length
Compatible equipment models: 3L7540:
Information:
Removal Procedure for One Temperature Regulator
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the engine into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change".
Disconnect the upper radiator hose from the water manifold.
Illustration 1 g00559394
Loosen hose clamps (2) . Remove bolts (1) . Remove regulator housing (3) .
Illustration 2 g00559396
Remove water temperature regulator (4) from regulator housing (3) .
Illustration 3 g00559403
Remove lip seal (5) from regulator housing (3) .
Illustration 4 g00593365
Remove gasket (7) from water manifold (6) . Do not reuse gasket (7) .
Illustration 5 g00593375
Remove bolts (8) from water manifold (6) .
Remove water manifold (6) and the gasket. Installation Procedure for One Temperature Regulator
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Illustration 6 g00593375
Position water manifold (6) with a new gasket on the cylinder head. Install bolts (8) .
Illustration 7 g00593365
Position a new gasket (7) on water manifold (6) .
Illustration 8 g00559403
Install lip seal (5) in regulator housing (3) . Ensure that lip seal (5) is fully seated in the counterbore of regulator housing (3) .
Illustration 9 g00559396
Install water temperature regulator (4) in regulator housing (3) .
Illustration 10 g00559394
Position regulator housing (3) with a new gasket on the water manifold. Install bolts (1) . Tighten bolts (1) to a torque of 50 9 N m (37 7 lb ft).
Position hose clamps (2) and tighten the clamps to a torque of 9 3 N m (80 27 lb in).Note: Refer to Specifications, "Water Lines" for more information on the position of hose clamps (3) .
Connect the upper radiator hose to the water manifold.
Fill the cooling system to the correct coolant level. Refer to Operation and Maintenance Manual, "Refill Capacities" in the Maintenance Section for more information.Removal Procedure for Two Temperature Regulators
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the engine into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change".
Disconnect the upper radiator hose from the housing assembly.
Illustration 11 g02721175
Disconnect the harness assembly from coolant temperature sensor (2) . Remove coolant temperature sensor (2)
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the engine into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change".
Disconnect the upper radiator hose from the water manifold.
Illustration 1 g00559394
Loosen hose clamps (2) . Remove bolts (1) . Remove regulator housing (3) .
Illustration 2 g00559396
Remove water temperature regulator (4) from regulator housing (3) .
Illustration 3 g00559403
Remove lip seal (5) from regulator housing (3) .
Illustration 4 g00593365
Remove gasket (7) from water manifold (6) . Do not reuse gasket (7) .
Illustration 5 g00593375
Remove bolts (8) from water manifold (6) .
Remove water manifold (6) and the gasket. Installation Procedure for One Temperature Regulator
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Illustration 6 g00593375
Position water manifold (6) with a new gasket on the cylinder head. Install bolts (8) .
Illustration 7 g00593365
Position a new gasket (7) on water manifold (6) .
Illustration 8 g00559403
Install lip seal (5) in regulator housing (3) . Ensure that lip seal (5) is fully seated in the counterbore of regulator housing (3) .
Illustration 9 g00559396
Install water temperature regulator (4) in regulator housing (3) .
Illustration 10 g00559394
Position regulator housing (3) with a new gasket on the water manifold. Install bolts (1) . Tighten bolts (1) to a torque of 50 9 N m (37 7 lb ft).
Position hose clamps (2) and tighten the clamps to a torque of 9 3 N m (80 27 lb in).Note: Refer to Specifications, "Water Lines" for more information on the position of hose clamps (3) .
Connect the upper radiator hose to the water manifold.
Fill the cooling system to the correct coolant level. Refer to Operation and Maintenance Manual, "Refill Capacities" in the Maintenance Section for more information.Removal Procedure for Two Temperature Regulators
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Drain the coolant from the engine into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change".
Disconnect the upper radiator hose from the housing assembly.
Illustration 11 g02721175
Disconnect the harness assembly from coolant temperature sensor (2) . Remove coolant temperature sensor (2)
Caterpillar parts catalog:
Parts belt Caterpillar catalog:
3L7539
BELT
D342C
D342C
4L6683
BELT
D342C
D342C
3L7539
BELT
D342C
D342C
3L7011
BELT
D353C
D353C
3L6052
BELT
D353C
D353C
2L8591
BELT
D353C
D353C
2L9492
BELT
D353C
D353C
3L1382
BELT
D342
D342
2964737
BELT-SERPENTINE
315D L, 318D L, 319D, 319D L, 319D LN
315D L, 318D L, 319D, 319D L, 319D LN
5L1584
BELT
D320A, D5, D5B
D320A, D5, D5B
2L5730
BELT
D320A
D320A
3L5751
BELT
824, D320A
824, D320A
2L4855
BELT
D320A
D320A
4L6683
BELT
D342C
D342C