Information:
Removal Procedure
Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from any utility and/or other generators that can provide power service), and either lock out or tag as "DO NOT OPERATE".
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
High voltage may be present. The power source must be disconnected before working on the equipment. Failure to disconnect the power source could result in injury or death. Verify that the equipment is not energized before performing any maintenance. This work must be performed by trained personnel with correct tools and procedures.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Open the AC breaker.
Disconnect the DC battery supply.
Illustration 1 g03332390
Packaged generators will have additional cable arrangements in the terminal box. Panel (1) shown in this picture is a factory shipping cover only.
Remove panel (1) .
Remove access panel (2) .
Illustration 2 g03326870
Illustration shows a generic configuration, there are differences between generator models and various options available.Note: Mark orientation of cable assemblies (3) prior to disconnecting.
Disconnect cable assemblies (3) and route through access panel (2) opening.
Illustration 3 g03330266
Remove air inlet screen (4) .
Illustration 4 g03330249
Remove terminal panel (5) and lifting eye (6) .
Illustration 5 g03326370
Remove panels (7) .
Illustration 6 g03326369
Remove terminal panel (8) .Installation Procedure
Install terminal box in the reverse order of removal.
Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from any utility and/or other generators that can provide power service), and either lock out or tag as "DO NOT OPERATE".
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
High voltage may be present. The power source must be disconnected before working on the equipment. Failure to disconnect the power source could result in injury or death. Verify that the equipment is not energized before performing any maintenance. This work must be performed by trained personnel with correct tools and procedures.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Open the AC breaker.
Disconnect the DC battery supply.
Illustration 1 g03332390
Packaged generators will have additional cable arrangements in the terminal box. Panel (1) shown in this picture is a factory shipping cover only.
Remove panel (1) .
Remove access panel (2) .
Illustration 2 g03326870
Illustration shows a generic configuration, there are differences between generator models and various options available.Note: Mark orientation of cable assemblies (3) prior to disconnecting.
Disconnect cable assemblies (3) and route through access panel (2) opening.
Illustration 3 g03330266
Remove air inlet screen (4) .
Illustration 4 g03330249
Remove terminal panel (5) and lifting eye (6) .
Illustration 5 g03326370
Remove panels (7) .
Illustration 6 g03326369
Remove terminal panel (8) .Installation Procedure
Install terminal box in the reverse order of removal.
Caterpillar parts catalog:
Parts bevel Caterpillar catalog:
9K0322
BEVEL GEAR
941, D4D, D4E
941, D4D, D4E
9K0322
BEVEL GEAR
941, D4D, D4E
941, D4D, D4E
8Q2120
BEVEL GEAR SET
RT100
RT100
3T8726
BEVEL AND TRANSFER GEAR
589, D5H
589, D5H
1192217
BEVEL GEAR SET
D6H, D6R, D6T
D6H, D6R, D6T
1192219
BEVEL GEAR SET - 14/39T
561M, D5H, D5N, D6M
561M, D5H, D5N, D6M
1192218
BEVEL GEAR SET - 18/38T
527, 561M, D5H, D5N, D6M
527, 561M, D5H, D5N, D6M
1186971
BEVEL PINION
527, 561M, D5H, D5M, D5N, D6M
527, 561M, D5H, D5M, D5N, D6M