Information:
Illustration 1 g00624871
Typical EMCP II With Caterpillar Monitoring System (1) Generator Set Control + (GSC+) (2) Alarm Module (ALM) (optional) (3) Custom Alarm Module (CAM) (4) Instrument Panel (5) Caterpillar Monitoring System Main Display Module (6) Caterpillar Monitoring System Scroll Switch (7) Caterpillar Monitoring System Clear/Mode Switch (8) Caterpillar Monitoring System LH/RH Select Switch (9) Engine Control Switch (ECS) (10) Emergency Stop Push Button (ESPB) (11) Speed Potentiometer (SP)Control Switches
The instrument panel has three switches that are used to control the Main Display Module (5).
CLEAR/MODE Switch (7) is used to move between the modes of operation. The switch is used to clear information that is currently displayed on the Main Display Module (5). Main Display Module (5) will cycle through the different modes of operation when CLEAR/MODE Switch (7) is held in the mode position. When the desired mode is reached, release the CLEAR/MODE Switch (7). The Main Display Module (5) will remain in that mode of operation until CLEAR/MODE Switch (7) is held down again. If the information that is currently displayed by the Main Display Module (5) is not needed you can clear the information from the memory. The displayed information can be cleared by holding CLEAR/MODE Switch (7) up for approximately one second until the information disappears from the Main Display Module (5).
SCROLL Switch (6) is used to scroll through the various parameters that are available in a single mode. Main Display Module (5) will scroll through the parameter display information that is available in the selected mode when SCROLL Switch (6) is held in the up position. If you want to display a parameter continuously, hold the SCROLL Switch (6) in the up position until the information is displayed. Then, release SCROLL Switch (6). The parameter information will remain displayed until Main Display Module (5) receives another switch signal.
LH/RH Switch (8) is used to display both the right and left hand parameter information on a single gauge. The LH/RH Switch (8) can be toggled back and forth. Instrument Panels that have 2 Gauge Modules can show values for the right side and the left side.Main Display Module
Illustration 2 g00625082
Caterpillar Monitoring System Block Diagram
Illustration 3 g00297407
Caterpillar Monitoring System Main Display ModuleThe Caterpillar Monitoring System for Generator Set applications with EMCP II/II+ consists of the following items:
Main display module
Various switches and sensorsThe main display module is the brain of the system. This module uses the CAT data link in order to receive information from the electronic components on the engine. The main display module processes this information. The readout on the main display module indicates the following types of information: "°F", "°C", "kPa", "PSI", "RPM", "LITER", "GAL/H", "-10", "VOLTS", Hour Meter symbol, "SERV CODE" and a six digit readout. These indicators are turned ON in order to correspond to the information that is shown on the readout. The readout
Parts bezel Caterpillar catalog:
3796807
BEZEL-TRIM CTR
Caterpillar
Caterpillar
3796792
BEZEL-TRIM
Caterpillar
Caterpillar
3796791
BEZEL-TRIM
Caterpillar
Caterpillar
3794351
BEZEL-
Caterpillar
Caterpillar
3785088
BEZEL-TRIM HOR
Caterpillar
Caterpillar
3784823
BEZEL-OUTER LH
Caterpillar
Caterpillar
3973288
BEZEL-
Caterpillar
Caterpillar
3973287
BEZEL-
Caterpillar
Caterpillar
3949918
BEZEL-HDLMP RH
Caterpillar
Caterpillar
3949915
BEZEL-HDLMP LH
Caterpillar
Caterpillar
3820242
BEZEL AS-TRIM
Caterpillar
Caterpillar
3820241
BEZEL AS-TRIM
Caterpillar
Caterpillar