5J6939 BIT-END Caterpillar parts
6A, 6S, 814S, D5B, D6D, D6E, D6E SR, D6G SR
Rating:
Alternative (cross code) number:
CA5J6939
5J-6939
5J6939
CA5J6939
5J-6939
5J6939
Weight: 0.18 pounds 0 kg.
BULLDOZER, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 5J6939:
Information:
Conditions Which Generate This Code:
Illustration 1 g02029084
Connections of the PTO 1 engagement solenoidThis diagnostic code is associated with the PTO 1 engagement solenoid. The FMI 05 means that the ECU has determined that an open in the circuit exists.The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECU has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 3524 FMI 05 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire R954-OR) to contact 2 (wire K972-BR).
Observe the status of the CID 3524 FMI 05.Expected Result:The diagnostic code is active. Then, the diagnostic code changes from FMI 05 to FMI 06 as the jumper wire is installed.Results:
YES - The FMI 05 diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The FMI 05 diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECU.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-2 (wire R954-OR) to contact J2-4 (wire K972-BR).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all of the harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 3524 FMI 05.Expected Result:The CID 3524 FMI 05 is active.Results:
YES - The CID 3524 FMI 05 is active. The diagnostic code has not
Illustration 1 g02029084
Connections of the PTO 1 engagement solenoidThis diagnostic code is associated with the PTO 1 engagement solenoid. The FMI 05 means that the ECU has determined that an open in the circuit exists.The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECU has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 3524 FMI 05 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire R954-OR) to contact 2 (wire K972-BR).
Observe the status of the CID 3524 FMI 05.Expected Result:The diagnostic code is active. Then, the diagnostic code changes from FMI 05 to FMI 06 as the jumper wire is installed.Results:
YES - The FMI 05 diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The FMI 05 diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECU.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-2 (wire R954-OR) to contact J2-4 (wire K972-BR).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all of the harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 3524 FMI 05.Expected Result:The CID 3524 FMI 05 is active.Results:
YES - The CID 3524 FMI 05 is active. The diagnostic code has not
Caterpillar parts catalog:
Parts bit Caterpillar catalog:
4J8261
BIT
5S, 6A, 6S, D5B, D6D, D6E, D6E SR, D6G SR
5S, 6A, 6S, D5B, D6D, D6E, D6E SR, D6G SR
4J8262
BIT
5S, 6A, 6S, D5B, D6D
5S, 6A, 6S, D5B, D6D
3G8297
BIT-END
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8298
BIT-END
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8319
BIT-END
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8320
BIT-END
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
4T3045
BIT-END
815B, 815F, 815F II, D6D, D6G2 LGP
815B, 815F, 815F II, D6D, D6G2 LGP
4T3046
BIT-END
815B, 815F, 815F II, D6D, D6G2 LGP
815B, 815F, 815F II, D6D, D6G2 LGP
3G7927
BIT
5S, D5B
5S, D5B
5J6927
BIT-END
7A, 814S, 824S, 826C, 8A
7A, 814S, 824S, 826C, 8A
5J6940
BIT-END
6A, 6S, 814S, D5B, D6D, D6E, D6E SR, D6G SR
6A, 6S, 814S, D5B, D6D, D6E, D6E SR, D6G SR
3G4285
BIT-END
D4H, D5H, D5HTSK II, D6M
D4H, D5H, D5HTSK II, D6M
1228618
BIT-END RH
D6H, D6H XL, D6H XR, D6R, D6R II
D6H, D6H XL, D6H XR, D6R, D6R II
1228617
BIT-END LH
D6H, D6H XL, D6H XR, D6R, D6R II
D6H, D6H XL, D6H XR, D6R, D6R II
9W6199
BIT-END-RH
D7E, D7E LGP, D7G, D7H, D7R, D7R II, D7R XR
D7E, D7E LGP, D7G, D7H, D7R, D7R II, D7R XR
8E7079
BIT-END
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5C, D5C III, D5G, D5K LGP, D5K2 XL
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5C, D5C III, D5G, D5K LGP, D5K2 XL
8E7078
BIT-END
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5C, D5C III, D5G, D5K LGP, D5K2 XL
D3K XL, D3K2 LGP, D4K XL, D4K2 XL, D5C, D5C III, D5G, D5K LGP, D5K2 XL
3G8320
BIT-END
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8319
BIT-END
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
D6D, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8298
BIT-END
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
3G8297
BIT-END
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL
527, D5B, D6E, D6E SR, D6G, D6G SR, D6G2 XL