3989171 BLOCK-WEAR Caterpillar parts
990K
Rating:
Alternative (cross code) number:
CA3989171
398-9171
3989171
CA3989171
398-9171
3989171
Weight: 9 pounds 4 kg.
WHEEL LOADER,
Compatible equipment models: 3989171:
Caterpillar parts catalog:
Information:
Follow the same procedure in Step 8 in order to enter the rate multiplier into the flow meter. The numbers for the rate multiplier will be shown on the bottom display.
Illustration 5 g00888814
A view of the flow analyzer and the touch pad is shown. (11) View divisor (12) Reset
Press view divisor (11) and hold the key for two to three seconds after the ten steps of the procedure are complete. The divisor and the rate multiplier will appear. This may require you to correct the numbers.Note: Use reset (12) to enter a number when a correction is required.
Open the housing. Move the calibration jumper to the DISABLE position. If you want reset (12) in disable mode, do the procedure now.Procedure for Liters and Liters Per Minute
Tilt the flow analyzer forward. Remove eight screws (1) that hold the front panel to the housing.
Open the housing carefully. The safety straps that are provided will prevent damage. This will also protect the wiring.
Enable both calibration (4) and reset (3) by moving the jumpers from the DISABLE position to the ENABLE position.
Place the front panel on the housing. Secure the panel with two screws for temporary use and for the divisor entry and the rate multiplier entry.
Calculate the number of liters per minute. Then multiply the number by ten. This is the calibration number or the divisor.
Illustration 6 g00761636
Illustration 7 g00888798
A view of the flow analyzer and the touch pad is enlarged. (5) "Enter/Step" (6) "Increment" (7) "Decimal Point" (8) "Access"
To enter the divisor, use the following steps:
Press "access" (8) and "enter/step" (5) in order to place the panel in the calibration mode.
Press "increment" (6). This should be done until you notice a 6 in the top right corner of the display.
Press "increment" (6) until you notice a 4 as the second digit.
Press "enter/step" (5) .
Press "increment" (6) until you notice a 1 as the third digit.
Press "enter/step" (5). This should produce an additional set of 0 on the display (4). An L will now appear.
Press "decimal point" (7). Continue until no decimal point shows. You now have a whole number 146 that is entered as the divisor.
Press "enter/ step" (5). A 0 will appear as the second digit at the right.
Calculate the rate multiplier for liters.
Illustration 8 g00761644
Enter the rate multiplier into the flow meter. The same procedure that is used for the divisor entry in liters from Step 8 should be followed.
When you complete the steps of the procedure, press "view divisor" (11) and hold the key for two or three seconds. The divisor and the rate multiplier will appear. This may require a correction of the numbers.Note: If a correction is needed in order to enter a number, "Reset" (12) can be used .
Open the housing. Move the calibrate jumper to the DISABLE position in order to disable "reset" (12) immediately.
Reassemble the front panel and the housing. The flow meter is now ready to be placed into service.
Check readouts for proper decals.Changing the Battery for the Water Control
Illustration 9 g00888829
Flow Readout Box
Parts block Caterpillar catalog:
3906273
BLOCK
844K, 990K
844K, 990K
3905955
BLOCK
950 GC
950 GC
3881190
BLOCK AS
980K HLG
980K HLG
4236089
BLOCK AS
980H
980H
2227858
BLOCK
966H, 972H
966H, 972H
6E3764
BLOCK
793F, 793F CMD, 793F-XQ, 797, 797B, 966H, 972H
793F, 793F CMD, 793F-XQ, 797, 797B, 966H, 972H
5J5246
BLOCK
950, 966C, 988
950, 966C, 988
4K3437
BLOCK
950
950
5K1011
BLOCK
814, 815, 816, 950, 966C, 980B
814, 815, 816, 950, 966C, 980B
9K7998
BLOCK
992
992
1475620
BLOCK
966M XE, 972M XE
966M XE, 972M XE
4275731
BLOCK
982M
982M