4373059 BLOCK-WEAR Caterpillar parts
Rating:
Alternative (cross code) number:
CA4373059
437-3059
4373059
CA4373059
437-3059
4373059
Weight: 13 pounds 6 kg.
Information:
Illustration 1 g01371788
Connections of the Implement Pilot Supply Solenoid
This diagnostic code is associated with the implement pilot supply solenoid. The FMI 06 diagnostic code indicates that the ECM has detected that the current for the solenoid circuit is above normal. Conditions that could cause this diagnostic code to be active are listed below:
The energize circuit of the solenoid is shorted to a ground source.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The active CID 0358 FMI 06 diagnostic code changes to a CID 0358 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 0358 FMI 06 diagnostic code changes to a CID 0358 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - The CID 0358 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUNDThe solenoid remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors of the ECM J1 and J2 from the ECM.
At the machine harness connectors of the ECM, measure the resistance from the signal contact J2-7 (wire G953-BU(Blue)) to frame ground. Measure the resistance from the signal contact J2-7 (wire G953-BU(Blue)) to all of the other contacts that are used in J1 and J2 ECM connectors.
While Observing the multimeter resistance measurements, wiggle the machine harness connectors for the ECM and the solenoid. Gently pull on the wires and wiggle the wires. Expected Result:Each resistance measurement is greater than 5000 ohms at all times during the manipulation of the harness and connectors.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One
Caterpillar parts catalog:
Parts block Caterpillar catalog:
4164445
BLOCK-VALVE
Caterpillar
Caterpillar
4164440
BLOCK GP-HYDRAULIC
Caterpillar
Caterpillar
3747219
BLOCK-VALVE
Caterpillar
Caterpillar
3744765
BLOCK GP-HYDRAULIC
Caterpillar
Caterpillar
3677347
BLOCK
Caterpillar
Caterpillar
3670873
BLOCK-VALVE
Caterpillar
Caterpillar
4503845
BLOCK-WEAR
Caterpillar
Caterpillar
4500621
BLOCK-LATCH
Caterpillar
Caterpillar
4494589
BLOCK
Caterpillar
Caterpillar
4480152
BLOCK
Caterpillar
Caterpillar
4424080
BLOCK AS-WEAR
Caterpillar
Caterpillar
4424062
BLOCK AS-WEAR
Caterpillar
Caterpillar