9J5927 BLOCK Caterpillar parts
D9L
Rating:
Alternative (cross code) number:
CA9J5927
9J-5927
9J5927
CA9J5927
9J-5927
9J5927
Weight: 206 pounds 93 kg.
TRACK-TYPE TRACTOR,
Compatible equipment models: 9J5927:
Information:
Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results
Caterpillar parts catalog:
Parts block Caterpillar catalog:
8S5383
BLOCK
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 16G, 16H NA, 225, 245, 245B, 24H, 30/3...
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 16G, 16H NA, 225, 245, 245B, 24H, 30/3...
9S3784
BLOCK
16, 245, 245B, 245D, 3406, 3406B, 3406C, 375, 578, 583R, 587R, 589, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 637G, 651B, 657B, 776, 777, 824B, 983B, 992, 992C, D10N, D10R, D8L,...
16, 245, 245B, 245D, 3406, 3406B, 3406C, 375, 578, 583R, 587R, 589, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 637G, 651B, 657B, 776, 777, 824B, 983B, 992, 992C, D10N, D10R, D8L,...
9G8451
BLOCK AS
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 315D L, 318D L, 318D2 L, 319D L, 319D LN, 320B FM LL, 320D, 320D L, 320D LRR, 320D RR, 322B...
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 315D L, 318D L, 318D2 L, 319D L, 319D LN, 320B FM LL, 320D, 320D L, 320D LRR, 320D RR, 322B...
7T4556
BLOCK
517, 527, D10N, D11N, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H XL, D6M, D7H, D9L, D9N, D9R
517, 527, D10N, D11N, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H XL, D6M, D7H, D9L, D9N, D9R
8N3052
BLOCK-MOUNTING
631E, 631G, 633E II, 637E, 637G, 651E, 657E, D10N, D9L, D9N, D9R
631E, 631G, 633E II, 637E, 637G, 651E, 657E, D10N, D9L, D9N, D9R
7G6009
BLOCK ASSEM.
639D, D9L
639D, D9L
7G3606
BLOCK
227, D9L, D9R
227, D9L, D9R
6Y1473
BLOCK
D10N, D10R, D9L, D9N
D10N, D10R, D9L, D9N
7G1324
BLOCK
D9L
D9L
3T9982
BLOCK
D9L
D9L
4T4914
BLOCK
D10, D8L, D9L
D10, D8L, D9L
9J5928
BLOCK
D9L
D9L
6T1020
BLOCK
D7G
D7G
6T1034
BLOCK
D7G
D7G
4T4914
BLOCK
D10, D8L, D9L
D10, D8L, D9L
1S1897
BLOCK
D10
D10
6P8098
BLOCK
D8K
D8K
9P5540
BLOCK
D8L
D8L
9V2197
BLOCK
814B
814B
3T4818
BLOCK
D9L
D9L
6T2134
BLOCK
D8L
D8L
6P2259
BLOCK
D9H
D9H