3180697 BODY-OIL PUMP Caterpillar parts
D6R, D6R STD
Rating:
Alternative (cross code) number:
CA3180697
318-0697
3180697
CA3180697
318-0697
3180697
Weight: 17 pounds 8 kg.
TRACK-TYPE TRACTOR,
Information:
Governor Type Setting
The "Governor Type Setting" parameter can be set to "Isochronous" or to "Droop". This setting is dependent upon the application of the engine.Engine Speed Droop
This programmable parameter allows precise control of the engine speed droop. The "Governor Type Setting" parameter must be set to "Droop" in order for this parameter to be active.Governor (Proportional) Gain Percentage
This parameter is based on a proportional multiplier. The "Governor (Proportional) Gain Percentage" determines the speed of the throttle actuator's response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed.This parameter is used for synchronization during engine operation at no load.Governor (Integral) Stability Percentage
This parameter is based on an integral multiplier. The "Governor (Integral) Stability Percentage" controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping.This parameter is used for synchronization during engine operation at no load.Governor Auxiliary 1 (Proportional) Gain Percentage
This parameter is based on a proportional multiplier. The "Governor Auxiliary 1 (Proportional) Gain Percentage" determines the speed of the throttle actuator's response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed.This parameter is used during loaded engine operation.Governor Auxiliary 1 (Integral) Stability Percentage
This parameter is based on an integral multiplier. The "Governor Auxiliary 1 (Integral) Stability Percentage" controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping.This parameter is used during loaded engine operation.Start/Stop Control
Driven Equipment Delay Time
The ECM accepts an input from the driven equipment that indicates when the equipment is ready for operation. When the input circuit is grounded, the driven equipment is ready. The ECM will not start the engine until this ECM input is grounded.The ECM can be programmed to wait for a certain period after receiving a start command before starting the engine. This allows the driven equipment to get ready for operation.When the ECM receives a start command, the ECM will wait for the amount of time that is programmed into the "Driven Equipment Delay Time". If the "Driven Equipment Delay Time" elapses and the input circuit is not grounded, an event code is activated. The engine will not start.If the "Driven Equipment Delay Time" is programmed to "0" the delay is disabled.Crank Terminate RPM
The ECM disengages the starting motor when the engine speed exceeds the programmed "Crank Terminate RPM". This parameter is preset at the factory and this value should be sufficient for all applications.Engine Purge Cycle Time
The "Engine Purge Cycle Time" is the duration of time for the engine to crank without fuel or spark during the crank cycle. The "Engine Purge Cycle Time" allows any unburned fuel to exit through the exhaust before the fuel and
The "Governor Type Setting" parameter can be set to "Isochronous" or to "Droop". This setting is dependent upon the application of the engine.Engine Speed Droop
This programmable parameter allows precise control of the engine speed droop. The "Governor Type Setting" parameter must be set to "Droop" in order for this parameter to be active.Governor (Proportional) Gain Percentage
This parameter is based on a proportional multiplier. The "Governor (Proportional) Gain Percentage" determines the speed of the throttle actuator's response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed.This parameter is used for synchronization during engine operation at no load.Governor (Integral) Stability Percentage
This parameter is based on an integral multiplier. The "Governor (Integral) Stability Percentage" controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping.This parameter is used for synchronization during engine operation at no load.Governor Auxiliary 1 (Proportional) Gain Percentage
This parameter is based on a proportional multiplier. The "Governor Auxiliary 1 (Proportional) Gain Percentage" determines the speed of the throttle actuator's response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed.This parameter is used during loaded engine operation.Governor Auxiliary 1 (Integral) Stability Percentage
This parameter is based on an integral multiplier. The "Governor Auxiliary 1 (Integral) Stability Percentage" controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping.This parameter is used during loaded engine operation.Start/Stop Control
Driven Equipment Delay Time
The ECM accepts an input from the driven equipment that indicates when the equipment is ready for operation. When the input circuit is grounded, the driven equipment is ready. The ECM will not start the engine until this ECM input is grounded.The ECM can be programmed to wait for a certain period after receiving a start command before starting the engine. This allows the driven equipment to get ready for operation.When the ECM receives a start command, the ECM will wait for the amount of time that is programmed into the "Driven Equipment Delay Time". If the "Driven Equipment Delay Time" elapses and the input circuit is not grounded, an event code is activated. The engine will not start.If the "Driven Equipment Delay Time" is programmed to "0" the delay is disabled.Crank Terminate RPM
The ECM disengages the starting motor when the engine speed exceeds the programmed "Crank Terminate RPM". This parameter is preset at the factory and this value should be sufficient for all applications.Engine Purge Cycle Time
The "Engine Purge Cycle Time" is the duration of time for the engine to crank without fuel or spark during the crank cycle. The "Engine Purge Cycle Time" allows any unburned fuel to exit through the exhaust before the fuel and
Caterpillar parts catalog:
Parts body Caterpillar catalog:
8J8782
BODY-DRAIN VALVE
1090, 1190, 1190T, 1290T, 1390, 173B, 183B, 193, 215, 215B, 225, 229, 2290, 235, 235B, 235D, 2390, 2391, 245, 245B, 2491, 24H, 24M, 2590, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 313D, 313D2...
1090, 1190, 1190T, 1290T, 1390, 173B, 183B, 193, 215, 215B, 225, 229, 2290, 235, 235B, 235D, 2390, 2391, 245, 245B, 2491, 24H, 24M, 2590, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 313D, 313D2...
1754292
BODY AS
1090, 1190, 1190T, 120H, 120K, 120K 2, 120M, 120M 2, 1290T, 12H, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 ...
1090, 1190, 1190T, 120H, 120K, 120K 2, 120M, 120M 2, 1290T, 12H, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 ...
1580250
BODY AS-LAMP
120H, 12H, 135H, 140H, 143H, 14H, 160H, 163H, 16H, 16M, 24M, 5110B, 5230B, 572R, 572R II, 583R, 583T, 587R, 587T, 613C II, 613G, 621G, 623G, 627G, 631G, 637G, 657G, 69D, 769D, 771D, 773D, 773E, 773F, ...
120H, 12H, 135H, 140H, 143H, 14H, 160H, 163H, 16H, 16M, 24M, 5110B, 5230B, 572R, 572R II, 583R, 583T, 587R, 587T, 613C II, 613G, 621G, 623G, 627G, 631G, 637G, 657G, 69D, 769D, 771D, 773D, 773E, 773F, ...
2058681
BODY AS
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
1008012
BODY
725, 730, 834K, 836K, 936F, BG-245C, D10T2, D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP, D7H, D7R, D7R II, D7R XR, D8N, D8R, D8R II, D8T, D9R, D9...
725, 730, 834K, 836K, 936F, BG-245C, D10T2, D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP, D7H, D7R, D7R II, D7R XR, D8N, D8R, D8R II, D8T, D9R, D9...
6T2307
BODY-VALVE
578, 583R, 587R, 589, D10N, D6H, D6H XL, D6H XR, D6R, D6R STD, D7H, D7R XR, D9L, D9R
578, 583R, 587R, 589, D10N, D6H, D6H XL, D6H XR, D6R, D6R STD, D7H, D7R XR, D9L, D9R
6I9875
BODY AS
D6H, D6H XL, D6H XR, D6R, D6R STD, D7H, D7R XR, D8N, D8R
D6H, D6H XL, D6H XR, D6R, D6R STD, D7H, D7R XR, D8N, D8R
9W1616
BODY-BRAKE CONTROL
D6H, D6H XL, D6H XR, D6R STD, D7H, D8N
D6H, D6H XL, D6H XR, D6R STD, D7H, D8N
3180694
BODY AS-OIL PUMP
D6R, D6R STD
D6R, D6R STD
3185040
BODY AS-OIL PUMP
D6R, D6R STD
D6R, D6R STD
3180694
BODY AS-OIL PUMP
D6R, D6R STD
D6R, D6R STD
2880535
BODY AS
D5R LGP, D6N
D5R LGP, D6N
1206858
BODY AS-VALVE
587T, D11R, D11T
587T, D11R, D11T
2701766
BODY AS-OIL PUMP
D6R III, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7R II
D6R III, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7R II
2263908
BODY AS-OIL PUMP
D6R III, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7R II
D6R III, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7R II
1654217
BODY AS-PRECLEANER
587R, D8L, D9N, D9R
587R, D8L, D9N, D9R
1066702
BODY
D5C III
D5C III
2382703
BODY AS-PISTON
611, 615C, 966F, 966F II, 972G, D250E II, D7G, D7H
611, 615C, 966F, 966F II, 972G, D250E II, D7G, D7H
1966847
BODY AS
834G, 834H, 836G, 836H, D6T LGP
834G, 834H, 836G, 836H, D6T LGP
3645382
BODY AS
PL83
PL83
3449027
BODY AS-OIL PUMP
D8T, PL83
D8T, PL83
3185040
BODY AS-OIL PUMP
D6R, D6R STD
D6R, D6R STD