Illustration 1 g01181789
Schematic for the Cat Data LinkTest Step 1. Inspect the Electrical Connectors and the Wiring
Turn the keyswitch to the OFF position.
Illustration 2 g01183529
Location of the P1 ECM connector (typical left side engine view)
Thoroughly inspect the J1/P1 ECM connectors. Also, thoroughly inspect each connector that is in the circuit for the Cat Data Link. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Illustration 3 g01104274
P1 terminals that are associated with the Cat Data Link (P1-8) Cat Data Link + (P1-9) Cat Data Link −
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the Cat Data Link.
Check the allen head screw on each ECM connector for the proper torque. Also, check the allen head screw on the customer connector for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and the connectors appear to be OK. Proceed to Test Step 2.
Not OK - The connectors and/or the wiring are not OK.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the original problem is resolved.STOPTest Step 2. Check for a Short Circuit
Disconnect the J1 connector.
Disconnect Cat ET from the service tool connector.
Measure the resistance between the points that are listed in Table 1. Be sure to wiggle the wires in the harnesses as you make each resistance measurement.
Table 1
Resistance Measurements for the Cat Data Link    
Connector and Terminal    Terminal    
P1-8 (Cat Data Link +)     All of the other terminals on the P1 connector    
Ground stud
P1-9 (Cat Data Link -)     All of the other terminals on the P1 connector    
Ground stud Expected Result:Each check of the resistance indicates an open circuit.Results:
OK - Each check of the resistance indicates an open circuit. Proceed to Test Step 3.
Not OK - At least one check of the resistance does not indicate an open circuit. There is a short circuit in the harness or in a connector.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Verify that the original problem is resolved.STOPTest Step 3. Check for an Open Circuit
Fabricate a jumper wire. Use the jumper wire in order to create a short circuit between terminals J63-D (Cat Data Link +) and J63-E (Cat Data Link −).
Measure the resistance between P1-8 (Cat Data Link +) and P1-9 (Cat Data Link −).Expected Result:Each check of the resistance is less than ten Ohms.Results:
OK - Each check of the resistance is less than ten Ohms.Repair: Perform the following procedure:
Connect the J1/P1 connectors. Connect Cat ET to the service tool connector.
Check the Cat Data Link for proper operation. If the data link does not operate correctly, there may be a problem with the ECM.Temporarily install a new ECM. Check the Cat Data