5B5473 BOLT Caterpillar parts
10, 16, 16G, 16H, 16H NA, 235, 235B, 235C, 235D, 245, 245B, 245D, 3606, 3608, 3612, 3616, 515, 518, 525, 528, 5S, 615, 615C, 621, 621B, 621E, 627, 627B, 627E, 69D, 6A, 6S, 768C, 769C, 769D, 771C, 771D...
Rating:
Alternative (cross code) number:
CA5B5473
5B-5473
5B5473
CA5B5473
5B-5473
5B5473
Weight: 1 pounds 0 kg.
Information:
GRIP LENGTH
101.6
mm
HEAD HEIGHT
17.93
mm
HEX SIZE
38.1
mm
LENGTH
165.1
mm
MATERIAL
Steel 1035 MPa Min Tensile Strength Rc 33-39
THREAD SIZE
1.00-8
COATING/PLATING
Phosphate and Oil Coating
ARTICULATED TRUCK, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$10.37
20 Nov 2023
Amazon.com
CTP 5B5473 Grade 8 Hex Head Plain Cap Screw, 1"-8 UNC Thread Size, 6-1/2" Length
CTP Hex Type of Head || Plain Coated || 1"-8 UNC Thread Size || 6-1/2" Length
CTP Hex Type of Head || Plain Coated || 1"-8 UNC Thread Size || 6-1/2" Length
$11.61
24 Jul 2022
1.6975[0.76] Pounds
US: TakePart
5B5473 Cap Screw High Head Fits Caterpillar
TCP Warranty
TCP Warranty
Compatible equipment models: 5B5473:
Information:
From the top level of the display, you can scroll through the logs and the telemetry data. Scrolling is accomplished with the soft keys. The keys are located at the bottom of the display and the right side of the display.
Table 1
Three-Phase Telemetry    
"Input Line Voltage A, B, and C"     This parameter is the measurement of the input voltages from the "A", "B", and "C" phases to neutral.    
"Phase - Phase Input Volts A, B, and C"     This parameter is the measurement of the phase voltage to the phase voltage. The measurement is made on the input side across phases "A", "B", and "C".    
"Current In Phases A, B, and C"     This parameter is the input current to the system, measured for each phase A, B, and C.    
"Input Power Phases A, B, and C"     This parameter is a calculated value based on the input phase to the neutral voltages and the input currents.    
"Input kVA Phases A, B, and C"     This parameter is a calculated value based on the input phase to the neutral voltages and the input currents.    
"Output Line Voltage Phases A, B, and C"     This parameter is a measurement of output voltages from phases A, B, and C to neutral.    
"Phase - Phase Output Volts A, B, and C"     This parameter is a measurement of the phase to phase voltages from the output phases A, B, and C.    
"Current Out Phases A, B, and C"     This parameter is the output current from the system, measured for each phase A, B, and C.    
"Output Power Phases A, B, and C"     This parameter is a calculated value based on the output phase to the neutral voltages and the output currents.    
"Output kVA Phases A, B, and C"     This parameter is a calculated value based on the output phase to the neutral voltages and the output currents.    
Table 2
Single Telemetry Points    
"Frequency"     This measurement is a measurement of the frequency as seen on phase C.    
"Output Power"     This measurement is the sum of the output power on phases A, B, and C.    
"Total Output kVA"     This measurement is the sum of the output kVA on phases A, B, and C.    
"Output Power Factor"     This measurement is calculated based on the output phase to the neutral voltages and the output currents.    
"Input Frequency"     This measurement is a measurement of the input frequency as seen on phase C.    
"Total Input Power"     This measurement is the sum of the input power on phases A, B, and C.    
"Total Input kVA"     This measurement is the sum of the input kVA on phases A, B, and C    
"Input Power Factor"     This measurement is calculated based on the input phase to the neutral voltages and the input currents.    
"Cabinet Temp"     This measurement is an
Table 1
Three-Phase Telemetry    
"Input Line Voltage A, B, and C"     This parameter is the measurement of the input voltages from the "A", "B", and "C" phases to neutral.    
"Phase - Phase Input Volts A, B, and C"     This parameter is the measurement of the phase voltage to the phase voltage. The measurement is made on the input side across phases "A", "B", and "C".    
"Current In Phases A, B, and C"     This parameter is the input current to the system, measured for each phase A, B, and C.    
"Input Power Phases A, B, and C"     This parameter is a calculated value based on the input phase to the neutral voltages and the input currents.    
"Input kVA Phases A, B, and C"     This parameter is a calculated value based on the input phase to the neutral voltages and the input currents.    
"Output Line Voltage Phases A, B, and C"     This parameter is a measurement of output voltages from phases A, B, and C to neutral.    
"Phase - Phase Output Volts A, B, and C"     This parameter is a measurement of the phase to phase voltages from the output phases A, B, and C.    
"Current Out Phases A, B, and C"     This parameter is the output current from the system, measured for each phase A, B, and C.    
"Output Power Phases A, B, and C"     This parameter is a calculated value based on the output phase to the neutral voltages and the output currents.    
"Output kVA Phases A, B, and C"     This parameter is a calculated value based on the output phase to the neutral voltages and the output currents.    
Table 2
Single Telemetry Points    
"Frequency"     This measurement is a measurement of the frequency as seen on phase C.    
"Output Power"     This measurement is the sum of the output power on phases A, B, and C.    
"Total Output kVA"     This measurement is the sum of the output kVA on phases A, B, and C.    
"Output Power Factor"     This measurement is calculated based on the output phase to the neutral voltages and the output currents.    
"Input Frequency"     This measurement is a measurement of the input frequency as seen on phase C.    
"Total Input Power"     This measurement is the sum of the input power on phases A, B, and C.    
"Total Input kVA"     This measurement is the sum of the input kVA on phases A, B, and C    
"Input Power Factor"     This measurement is calculated based on the input phase to the neutral voltages and the input currents.    
"Cabinet Temp"     This measurement is an
Cat SIS web machinery list:
Parts bolt Caterpillar catalog:
8T5881
BOLT
D11N, D11R, D11T
D11N, D11R, D11T
5P5422
BOLT
D10, D10N, D10R, D10T, D10T2
D10, D10N, D10R, D10T, D10T2
5P6783
BOLT-PLOW
825C, 825G, 825G II, 825H, 825K
825C, 825G, 825G II, 825H, 825K
2S1216
BOLT
D7F, D8H
D7F, D8H
5P0233
BOLT
D9G, D9H
D9G, D9H
8T6468
BOLT
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
6G0901
BOLT
16G, 16H, 16H NA
16G, 16H, 16H NA
8T6470
BOLT-LOCKING
16G, 16H, 16H NA
16G, 16H, 16H NA
4F3665
BOLT
16
16
6D8671
BOLT
12F, 14E, 14G, 16
12F, 14E, 14G, 16
1520194
BOLT-HEX HEAD
3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
1520193
BOLT-HEX HEAD
3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
6V8807
BOLT
206, 206B, 212, 212B, 231D, 3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
206, 206B, 212, 212B, 231D, 3606, 3608, 3612, 3616, C280-16, G3606, G3608, G3612, G3616
7W0855
BOLT
3606, 3608, 3612, 3616, 3618, 651E, 657E, 657G, C280-12, C280-16, C280-6, C280-8, G3606, G3606B, G3608, G3612, G3616
3606, 3608, 3612, 3616, 3618, 651E, 657E, 657G, C280-12, C280-16, C280-6, C280-8, G3606, G3606B, G3608, G3612, G3616
2325201
BOLT
C1.5
C1.5
8T1812
BOLT
3606, 3608, 3612, 3616, 3618, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
3606, 3608, 3612, 3616, 3618, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
7X3324
BOLT-12 POINT HEAD
3608, 3612, 3616, C280-12, C280-8, G3608, G3612
3608, 3612, 3616, C280-12, C280-8, G3608, G3612
7X3154
BOLT-12 POINT HEAD
3608, 3612, 3616, C280-12, C280-8, G3608, G3612
3608, 3612, 3616, C280-12, C280-8, G3608, G3612
7X3153
BOLT-12 POINT HEAD
3612, 3616, 3618, C280-16, C280-6, G3612, G3616
3612, 3616, 3618, C280-16, C280-6, G3612, G3616
3S7079
BOLT
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, D8H, D8K, D8L, G3606, G3606B, G3608, G3612, G3616
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, D8H, D8K, D8L, G3606, G3606B, G3608, G3612, G3616
8D9512
BOLT
3606, 3608, 3612, 3616, 631C, 641B, 650B, 657B, 784B, 784C, 785, 785B, 785C, 785D, 789, C280-16, C280-8, G3606, G3606B, G3608, G3612, G3616
3606, 3608, 3612, 3616, 631C, 641B, 650B, 657B, 784B, 784C, 785, 785B, 785C, 785D, 789, C280-16, C280-8, G3606, G3606B, G3608, G3612, G3616