5P7688 BOLT Caterpillar parts
3192, 508, 7241, 7251
Rating:
Alternative (cross code) number:
CA5P7688
5P-7688
5P7688
CA5P7688
5P-7688
5P7688
Weight: 0.50 pounds 0 kg.
Information:
GRIP LENGTH
12.7
mm
HEAD HEIGHT
17.07
mm
HEX SIZE
33.34
mm
LENGTH
63.5
mm
MATERIAL
Steel 1035 MPa Min Tensile Strength Rc 33-39
THREAD SIZE
.88-9
SELF LOCKING
Non Metallic
MARINE GEAR, WHEEL SKIDDER,
Compatible equipment models: 5P7688:
Information:
AC Power Wiring Connections
Determine the AC currents for your system based on kVA, voltage, and installed options. Also refer to equipment nameplates for the model number, rating, and voltage.
All Power connections must be completed by a licensed electrician that is experienced in wiring the UPS type of equipment. Wiring must be installed in accordance with the National Electrical Code (NEC) and all applicable local. Improper wiring may cause equipment damage or injury to personnel. Verify that all incoming high and low voltage power circuits are de-energized. Verify that all incoming high and low voltage power circuits locked out before installing cables or making electrical connections.
The UPS is designed for the cables to enter the cabinet top or bottom. Removable access plates must be cut in order to accommodate the conduit size. Input cables and output cables must be run in separate conduits.The connection terminals are drilled for 1/2 inch hardware and spaced for one or two hole NEMA lugs.Connection terminals can be oriented for top entry or bottom entry. Orienting the terminals in the direction of cable entry will minimize the number of bends in the cables. Space limitations require smaller cables installed parallel to one another. The use of smaller cables reduces the risk of damage to the unit or the cables while pulling the cables.Note: The lugs and the cables are not supplied. Refer to "NEC Article 210-19" and the "NEC Table 310-16" for the correct size of the cables. Refer to "NEC Article 250-95" for the correct size of the ground. Refer to "NEC Article 310-15" for the correct size of the neutral.The torque for the wire connections is 61 N m (45 lb ft).Note: A service disconnect device must be installed. The disconnect device must be rated properly for the output power. The disconnect device is not supplied.
The following wires and cables must be housed in an individual, separate conduit or cable tray. Placing multiple cables in the same conduit with other control or power wiring may cause the system to fault.
All shielded cables
Non-shielded cables
Non-shielded control wires
Non-shielded remote control wires
Verify that utility power and overcurrent protection ratings will accommodate the UPS input rating.
A safety ground wire must be installed from building ground to the ground point in the UPS module cabinet. The grounding conductor must comply with the following conditions of installation.
The insulated grounding conductor must be sized in accordance with the NEC, in the USA, and all other local and national codes. The insulated grounding conductor must be installed as part of the branch circuit that supplies power to the unit or system.
The grounding conductor must have an earth ground at the service equipment. If the system is supplied by a separately derived system, the grounding conductor must have an earth ground at the supply transformer or generator set.
Attachment plug receptacles used in the vicinity of the unit or system must be grounding type. The grounding conductors serving the attachment plug receptacles are to be connected to earth ground at the service equipment.
Observe
Determine the AC currents for your system based on kVA, voltage, and installed options. Also refer to equipment nameplates for the model number, rating, and voltage.
All Power connections must be completed by a licensed electrician that is experienced in wiring the UPS type of equipment. Wiring must be installed in accordance with the National Electrical Code (NEC) and all applicable local. Improper wiring may cause equipment damage or injury to personnel. Verify that all incoming high and low voltage power circuits are de-energized. Verify that all incoming high and low voltage power circuits locked out before installing cables or making electrical connections.
The UPS is designed for the cables to enter the cabinet top or bottom. Removable access plates must be cut in order to accommodate the conduit size. Input cables and output cables must be run in separate conduits.The connection terminals are drilled for 1/2 inch hardware and spaced for one or two hole NEMA lugs.Connection terminals can be oriented for top entry or bottom entry. Orienting the terminals in the direction of cable entry will minimize the number of bends in the cables. Space limitations require smaller cables installed parallel to one another. The use of smaller cables reduces the risk of damage to the unit or the cables while pulling the cables.Note: The lugs and the cables are not supplied. Refer to "NEC Article 210-19" and the "NEC Table 310-16" for the correct size of the cables. Refer to "NEC Article 250-95" for the correct size of the ground. Refer to "NEC Article 310-15" for the correct size of the neutral.The torque for the wire connections is 61 N m (45 lb ft).Note: A service disconnect device must be installed. The disconnect device must be rated properly for the output power. The disconnect device is not supplied.
The following wires and cables must be housed in an individual, separate conduit or cable tray. Placing multiple cables in the same conduit with other control or power wiring may cause the system to fault.
All shielded cables
Non-shielded cables
Non-shielded control wires
Non-shielded remote control wires
Verify that utility power and overcurrent protection ratings will accommodate the UPS input rating.
A safety ground wire must be installed from building ground to the ground point in the UPS module cabinet. The grounding conductor must comply with the following conditions of installation.
The insulated grounding conductor must be sized in accordance with the NEC, in the USA, and all other local and national codes. The insulated grounding conductor must be installed as part of the branch circuit that supplies power to the unit or system.
The grounding conductor must have an earth ground at the service equipment. If the system is supplied by a separately derived system, the grounding conductor must have an earth ground at the supply transformer or generator set.
Attachment plug receptacles used in the vicinity of the unit or system must be grounding type. The grounding conductors serving the attachment plug receptacles are to be connected to earth ground at the service equipment.
Observe
Caterpillar parts catalog:
Parts bolt Caterpillar catalog:
1B7182
BOLT
1140, 1145, 1150, 1160, 117, 118, 120G, 12E, 12G, 130G, 140G, 140H, 141, 143H, 14E, 14G, 14H, 16, 160G, 160H, 163, 163H, 1673, 1673C, 1674, 1676, 1693, 16G, 16H, 16H NA, 183, 183B, 184, 191, 205B, 214...
1140, 1145, 1150, 1160, 117, 118, 120G, 12E, 12G, 130G, 140G, 140H, 141, 143H, 14E, 14G, 14H, 16, 160G, 160H, 163, 163H, 1673, 1673C, 1674, 1676, 1693, 16G, 16H, 16H NA, 183, 183B, 184, 191, 205B, 214...
3B1915
BOLT
120G, 130G, 140B, 14G, 1673C, 215B, 225, 245, 30/30, 3116, 3145, 3150, 3160, 3176B, 3176C, 3181, 3192, 3196, 3204, 3208, 3304, 3304B, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C,...
120G, 130G, 140B, 14G, 1673C, 215B, 225, 245, 30/30, 3116, 3145, 3150, 3160, 3176B, 3176C, 3181, 3192, 3196, 3204, 3208, 3304, 3304B, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C,...
0308535
BOLT-LOCKING
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 153, 160G, 160H, 160H ES, 160H...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 153, 160G, 160H, 160H ES, 160H...
1D4569
BOLT
117, 120, 120B, 12E, 12G, 12H, 12H ES, 12H NA, 130G, 140, 140B, 140G, 140H, 140H ES, 140H NA, 141, 143H, 14E, 14G, 14H, 14H NA, 153, 16, 160G, 160H, 160H ES, 160H NA, 163, 163H, 163H NA, 1674, 1676, 1...
117, 120, 120B, 12E, 12G, 12H, 12H ES, 12H NA, 130G, 140, 140B, 140G, 140H, 140H ES, 140H NA, 141, 143H, 14E, 14G, 14H, 14H NA, 153, 16, 160G, 160H, 160H ES, 160H NA, 163, 163H, 163H NA, 1674, 1676, 1...
0S1616
BOLT
10-20B, 118, 120, 120B, 120G, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 130G, 140, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14E, 14G, 14H NA, 16, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673, 1673B, 1673C, ...
10-20B, 118, 120, 120B, 120G, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 130G, 140, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14E, 14G, 14H NA, 16, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673, 1673B, 1673C, ...
9S1366
BOLT
10S, 120B, 120G, 120H, 120H ES, 120H NA, 128, 12F, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 141, 143H, 14E, 14G, 14H, 14H NA, 153, 16, 160G, 160H, 160H E...
10S, 120B, 120G, 120H, 120H ES, 120H NA, 128, 12F, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 141, 143H, 14E, 14G, 14H, 14H NA, 153, 16, 160G, 160H, 160H E...
8T0292
BOLT
120G, 120H, 120K, 120K 2, 12G, 12H, 12K, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14M, 160G, 160H, 160K, 160M, 160M 2, 160M 3, 1...
120G, 120H, 120K, 120K 2, 12G, 12H, 12K, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14M, 160G, 160H, 160K, 160M, 160M 2, 160M 3, 1...
6H1717
BOLT
117, 118, 120, 120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 127, 128, 129, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140G, 140...
117, 118, 120, 120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 127, 128, 129, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140G, 140...
0S1629
BOLT
130G, 24M, 3116, 3176, 3176B, 3208, 3304, 44, 508, 518, 518C, 530B, 561B, 561C, 561D, 571G, 572G, 594, 594H, 657, 657B, 65E, 75E, 770, 772, 777F, 85E, 95E, 963, 963B, 973, 977, 980F, 980F II, BH150, C...
130G, 24M, 3116, 3176, 3176B, 3208, 3304, 44, 508, 518, 518C, 530B, 561B, 561C, 561D, 571G, 572G, 594, 594H, 657, 657B, 65E, 75E, 770, 772, 777F, 85E, 95E, 963, 963B, 973, 977, 980F, 980F II, BH150, C...
0T0319
BOLT
120B, 120G, 12G, 130G, 140G, 14G, 153, 16, 160G, 1673B, 1673C, 1693, 16G, 172, 173B, 183B, 215, 215B, 215C, 225, 227, 229, 235, 235B, 245, 3160, 3204, 3208, 3306, 3406, 3406C, 3408, 3408B, 3412, 3412C...
120B, 120G, 12G, 130G, 140G, 14G, 153, 16, 160G, 1673B, 1673C, 1693, 16G, 172, 173B, 183B, 215, 215B, 215C, 225, 227, 229, 235, 235B, 245, 3160, 3204, 3208, 3306, 3406, 3406C, 3408, 3408B, 3412, 3412C...
1F4111
BOLT
1140, 1145, 1150, 1160, 120B, 12F, 140B, 14E, 1693, 225, 245, 3160, 3208, 3304, 3306, 3306C, 3406B, 3406C, 3408B, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 374F L...
1140, 1145, 1150, 1160, 120B, 12F, 140B, 14E, 1693, 225, 245, 3160, 3208, 3304, 3306, 3306C, 3406B, 3406C, 3408B, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 374F L...
0S1584
BOLT
118, 120, 120B, 129, 12E, 140, 140B, 14E, 1673, 1676, 24, 3516C, 44, 46, 508, 517, 518, 518C, 528, 561B, 561C, 572G, 583H, 583K, 594, 594H, 613, 613B, 613C, 613C II, 621, 627, 627B, 627E, 627F, 627G, ...
118, 120, 120B, 129, 12E, 140, 140B, 14E, 1673, 1676, 24, 3516C, 44, 46, 508, 517, 518, 518C, 528, 561B, 561C, 572G, 583H, 583K, 594, 594H, 613, 613B, 613C, 613C II, 621, 627, 627B, 627E, 627F, 627G, ...
5K7143
BOLT
120G, 12G, 130G, 140G, 14G, 16G, 16H, 16H NA, 16M, 225, 229, 235D, 245B, 24H, 24M, 3192, 3408, 3412, 515, 518C, 525, 528, 613, 621, 621B, 621E, 621F, 621G, 621R, 623B, 623E, 623F, 623G, 627B, 627E, 62...
120G, 12G, 130G, 140G, 14G, 16G, 16H, 16H NA, 16M, 225, 229, 235D, 245B, 24H, 24M, 3192, 3408, 3412, 515, 518C, 525, 528, 613, 621, 621B, 621E, 621F, 621G, 621R, 623B, 623E, 623F, 623G, 627B, 627E, 62...
3H7917
BOLT
3181, 3192, 633E, 7241, 7251, 7261, 7271
3181, 3192, 633E, 7241, 7251, 7261, 7271
6V7526
BOLT GROUND BODY
3192, 7241, 7251, 7261, 7271
3192, 7241, 7251, 7261, 7271
9S8493
BOLT ROD CAP BOLTS
594, D342, D353C, D8K, D9H
594, D342, D353C, D8K, D9H
0684117
BOLT 19 mm (3/4 inches) x 273 mm (10.75 length)
D353C, D7H, D8N, D9G, D9H, G3520C, G3520E, G353D
D353C, D7H, D8N, D9G, D9H, G3520C, G3520E, G353D
1D4624
BOLT 19 mm (3/4 inches) x 229 mm (9 inches)
16, 215B, 3508, 3512, 3516, 651B, 651E, 657B, 657E, 657G, 773G LRC, 773G OEM, 775G LRC, 775G OEM, 776C, 776D, 777, 777B, 777C, 777D, 777F, 777G, 785, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 7...
16, 215B, 3508, 3512, 3516, 651B, 651E, 657B, 657E, 657G, 773G LRC, 773G OEM, 775G LRC, 775G OEM, 776C, 776D, 777, 777B, 777C, 777D, 777F, 777G, 785, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 7...
O310219
BOLT
7261
7261
O310220
BOLT
7261
7261
5P7783
BOLT
7261, D10
7261, D10
O343557
BOLT
7261
7261
O312701
BOLT
7261
7261
5P7782
BOLT
3192, 3208, 7261, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 844, 844H, 844K, 854G, 854K, 990 II, 990H, 990K, 992G, 992K
3192, 3208, 7261, 814B, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 844, 844H, 844K, 854G, 854K, 990 II, 990H, 990K, 992G, 992K