6T2162 BOLT Caterpillar parts
D6H, D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL, D7H
Rating:
Alternative (cross code) number:
CA6T2162
6T-2162
6T2162
CA6T2162
6T-2162
6T2162
Weight: 0.70 pounds 0 kg.
Information:
BODY DIAMETER
19.86
mm
GRIP LENGTH
75
mm
HEAD HEIGHT
19
mm
HEX SIZE
28.58
mm
LENGTH
105
mm
MATERIAL
Steel - Min Tensile Strength 1170 MPa - Rockwell C37-42
STYLE
STANDARD
THREAD SIZE
.75-16
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$3.39
12 Dec 2022
Amazon.com
CTP 6T2162 Grade 9 Track Plain Bolt, 3/4"-16 UNF Thread Size, 104.9mm Length
CTP Track Type of Head || Plain Coated || 3/4"-16 UNF Thread Size || 104.9mm Length
CTP Track Type of Head || Plain Coated || 3/4"-16 UNF Thread Size || 104.9mm Length
Compatible equipment models: 6T2162:
Information:
MID 027 CID 0826 FMI 04Conditions Which Generate This Code:
Illustration 1 g01309852
Connections of the torque converter oil temperature sensor
The diagnostic code is associated with the transmission oil temperature sensor. The FMI 04 means that the ECM has determined that the voltage of the circuit for the sensor is below normal.The possible causes for this diagnostic code are listed:
The sensor supply circuit to the transmission oil temperature sensor is shorted to ground.
A sensor has failed.
The power train ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0826 FMI 04 is active before performing this procedure.Note: Use the digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SENSOR
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from the machine harness. Expected Result:The CID 0826 FMI 04 remains active. The FMI has not changed and the "04" is still active.Results:
OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
NOT OK - The diagnostic code is no longer active. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the sensor.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector for the ECM, measure the resistance from the signal contact J2-24 (wire F704-BU(Blue)) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness. The short is between signal contact J2-24 (wire F704-BU(Blue)) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0826 FMI 04 is active. Expected Result:The CID 0826 FMI 04 is active.Results:
YES - The CID 0826 FMI 04 is active. The problem has not
Illustration 1 g01309852
Connections of the torque converter oil temperature sensor
The diagnostic code is associated with the transmission oil temperature sensor. The FMI 04 means that the ECM has determined that the voltage of the circuit for the sensor is below normal.The possible causes for this diagnostic code are listed:
The sensor supply circuit to the transmission oil temperature sensor is shorted to ground.
A sensor has failed.
The power train ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0826 FMI 04 is active before performing this procedure.Note: Use the digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SENSOR
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from the machine harness. Expected Result:The CID 0826 FMI 04 remains active. The FMI has not changed and the "04" is still active.Results:
OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
NOT OK - The diagnostic code is no longer active. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the sensor.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector for the ECM, measure the resistance from the signal contact J2-24 (wire F704-BU(Blue)) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness. The short is between signal contact J2-24 (wire F704-BU(Blue)) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0826 FMI 04 is active. Expected Result:The CID 0826 FMI 04 is active.Results:
YES - The CID 0826 FMI 04 is active. The problem has not
Cat SIS web machinery list:
Parts bolt Caterpillar catalog:
5J2409
BOLT-PLOW
320C, 320D, 324D L, 325B L, 325C, 325D L, 328D LCR, 329D L, 615, 7A, 7S, 814F, 814F II, 814S, 816B, 816F, 816F II, 824C, 824S, 826H, 834B, 8A, 8U, D6R III, D6T, D6T LGP, D6T XL, D7G, D7G2, D7H, G320, ...
320C, 320D, 324D L, 325B L, 325C, 325D L, 328D LCR, 329D L, 615, 7A, 7S, 814F, 814F II, 814S, 816B, 816F, 816F II, 824C, 824S, 826H, 834B, 8A, 8U, D6R III, D6T, D6T LGP, D6T XL, D7G, D7G2, D7H, G320, ...
7X2582
BOLT
320C FM, 325C FM, 330C FM, 330D, 345C L, 345D, 349D L, 365B II, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5080, 5090B, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 79...
320C FM, 325C FM, 330C FM, 330D, 345C L, 345D, 349D L, 365B II, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 5080, 5090B, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 79...
7Y5235
BOLT
325 L, 325C, 328D LCR, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C ...
325 L, 325C, 328D LCR, 330, 330 FM L, 330 L, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C ...
7X0429
BOLT
10-20B, 12M 2, 140M, 160M, 515, 525, 587T, AP-1055D, AS3251C, AS3301C, BG-2455D, BG-260D, CB-614, CP-433C, CP-433E, CP-44, CP-56, CP-563, CP-573E, CP-64, CP-68B, CP-74B, CS-323C, CS-433C, CS-433E, CS-...
10-20B, 12M 2, 140M, 160M, 515, 525, 587T, AP-1055D, AS3251C, AS3301C, BG-2455D, BG-260D, CB-614, CP-433C, CP-433E, CP-44, CP-56, CP-563, CP-573E, CP-64, CP-68B, CP-74B, CS-323C, CS-433C, CS-433E, CS-...
7X0392
BOLT
844, 844H, 844K, 973, CS-323, D10N, D10R, D11R, D6G, D6G2 LGP, D6G2 XL, D7H, D7R, D7R II, D7R XR, D8R, D8R II, D9N, D9R
844, 844H, 844K, 973, CS-323, D10N, D10R, D11R, D6G, D6G2 LGP, D6G2 XL, D7H, D7R, D7R II, D7R XR, D8R, D8R II, D9N, D9R
2H1537
BOLT
14G, 16G, 789D, 966D, 992C, CP-433B, D10N, D10R, D10T, D10T2, D7H, D7R, D8L, D8R, D9E, D9L, D9N, D9R, D9T
14G, 16G, 789D, 966D, 992C, CP-433B, D10N, D10R, D10T, D10T2, D7H, D7R, D8L, D8R, D9E, D9L, D9N, D9R, D9T
6V0314
BOLT
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA, 173B, 621B, 621E, 623B, 623E, 627B, 627E, 633D, 637D, 637E, 639D, 641B, 651B, 651E, 657B, 657E, 943, 953, D11R, D11T, D250D, D250E, D300E, D3...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA, 173B, 621B, 621E, 623B, 623E, 627B, 627E, 633D, 637D, 637E, 639D, 641B, 651B, 651E, 657B, 657E, 943, 953, D11R, D11T, D250D, D250E, D300E, D3...
3F9025
BOLT
528B, 530B, 630B, 789, 789B, 789C, 789D, 8 SR, 824S, 826C, 836, 966D, D7H
528B, 530B, 630B, 789, 789B, 789C, 789D, 8 SR, 824S, 826C, 836, 966D, D7H
2B1955
BOLT
966C, 988B, 994, D6H, D9R
966C, 988B, 994, D6H, D9R
6T1441
BOLT-TRACK
D6H, D7H
D6H, D7H
7X0434
BOLT
834B, 966D, 966F, D11N, D11R, D11T, D7H, D7R, D7R II, D8N, D8R, D8R II, PR-1000, RM-300, RM-350B, RM-500, SM-350
834B, 966D, 966F, D11N, D11R, D11T, D7H, D7R, D7R II, D8N, D8R, D8R II, PR-1000, RM-300, RM-350B, RM-500, SM-350
9T4137
BOLT
320C, 938H, D6N, D7H, D8N
320C, 938H, D6N, D7H, D8N
6V1792
BOLT
1090, 1190, 1190T, 1390, 2390, 2391, 320C FM, 320D, 320D FM, 320D FM RR, 322C, 324D FM, 325C FM, 325C L, 325D FM, 325D FM LL, 517, 521, 522, 527, 953C, 963C, D5H, D5H XL, D5HTSK II, D5R LGP, D6H, D6H ...
1090, 1190, 1190T, 1390, 2390, 2391, 320C FM, 320D, 320D FM, 320D FM RR, 322C, 324D FM, 325C FM, 325C L, 325D FM, 325D FM LL, 517, 521, 522, 527, 953C, 963C, D5H, D5H XL, D5HTSK II, D5R LGP, D6H, D6H ...
3T3884
BOLT-TRACK
561N, D250B, D250D, D250E, D300B, D300D, D4H, D4H XL, D5H, D5K LGP, D5K2 XL, D5M, D5N
561N, D250B, D250D, D250E, D300B, D300D, D4H, D4H XL, D5H, D5K LGP, D5K2 XL, D5M, D5N
9G3110
BOLT
561H, 561M, 561N, 939, 939C, 953C, 953D, D4H, D4H XL, D4HTSK II, D4HTSK III, D5C, D5C III, D5G, D5H, D5H XL, D5HTSK II, D5K LGP, D5K2 XL, D5M, D5N, D6R
561H, 561M, 561N, 939, 939C, 953C, 953D, D4H, D4H XL, D4HTSK II, D4HTSK III, D5C, D5C III, D5G, D5H, D5H XL, D5HTSK II, D5K LGP, D5K2 XL, D5M, D5N, D6R
1T0102
BOLT
941, D4E
941, D4E
4F7937
BOLT
D5B
D5B
4F5957
BOLT
D5B
D5B
9S1322
BOLT
120H, 120H ES, 120H NA, 12F, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14G, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 320D, 324D L, 325B L, 325C, 325D L, 329D L,...
120H, 120H ES, 120H NA, 12F, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14G, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 320D, 324D L, 325B L, 325C, 325D L, 329D L,...
1563888
BOLT-12 POINT HEAD
D10R, D6R, D7R, D8R
D10R, D6R, D7R, D8R
1563884
BOLT-HEAD
D10R, D6R, D7R, D8R
D10R, D6R, D7R, D8R
1563875
BOLT
D6R, D7R
D6R, D7R
1548390
BOLT-SOCKET HEAD
D10R, D6R, D7R, D8R, D9R
D10R, D6R, D7R, D8R, D9R
0191209
BOLT-SOCKET HEAD
613, 966M, 966M XE, 972M, 972M XE, 980M, 982M, D6R, D7R
613, 966M, 966M XE, 972M, 972M XE, 980M, 982M, D6R, D7R