7K3116 BOLT-12 POINT HEAD Caterpillar parts
3408B, 3408C, 3412, 3412C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 578, 583R, 589, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777C, 777D, 777F, 777G, 834B, 836, 844H,...
Rating:
Alternative (cross code) number:
CA7K3116
7K-3116
7K3116
CA7K3116
7K-3116
7K3116
Weight: 0.30 pounds 0 kg.
Information:
GRIP LENGTH
38.1
mm
HEAD DIAMETER
23.83
mm
HEAD HEIGHT
15.88
mm
LENGTH
88.9
mm
MATERIAL
Steel 1170 MPa Min Tensile Strength
THREAD SIZE
.62-11
GAS ENGINE, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
This part in 2 request:
Show.
This information for suppliers only!
2023-09-22
2021-12-01
Compatible equipment models: 7K3116:
Information:
System Operation Description:If the voltage drops below the generator under voltage percentage threshold or the automatic voltage regulator (AVR) request set point value, the under voltage timer will begin timing. When the timer expires, the generator under voltage event is made active (if the frequency has been below the threshold level continuously while timing). If the voltage rises above the generator under voltage percentage threshold, the generator under voltage event will be made inactive. The timer will be reset. If an under voltage condition is detected, "GEN UNDERVOLTAGE SHUTDOWN" or "GEN UNDERVOLTAGE " will be displayed on the EMCP 3. The message is used to inform the operator of an under voltage condition.Note: The severity of the under voltage condition will determine if a warning or shutdown event occurs.The code for generator under voltage is generated when the EMCP 3 determines that a generator under voltage condition has occurred.Test Step 1. TALK TO THE OPERATOR.
Determine the conditions that caused the under voltage condition.Expected Result:An under voltage was caused by an occurrence known to the operator. The operator would like to put the generator set back into service.Results:
OK - The operator can determine the cause for the under voltage condition. The condition has been repaired and the operator wants to put the generator set back into service.Repair: Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOP
NOT OK - The under voltage condition was not caused by an occurrence known to the operator. Proceed to Test Step 2.Test Step 2. CHECK THE SET POINTS.
View the following set points:
Generator under voltage
Automatic voltage regulator (AVR) desired voltage request
Generator AC monitorMake a note of the set points. Refer to Testing and Adjusting, RENR7902, "Electronic Control Module (Generator Set) - Configure". Compare the set points against the default set points of the particular generator set.Expected Result:The set points are correct.Results:
OK - The set points are correct for your particular generator set. Proceed to Test Step 3.
NOT OK - The set points are NOT correct.Repair: Reprogram the set points. Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOPTest Step 3. VERIFY VOLTAGE CAN BE ADJUSTED.Verify that the generator output voltage can be adjusted from the EMCP 3 display.Expected Result:The generator output voltage can be adjusted from the EMCP 3 display.Results:
OK - The generator output voltage can be changed from the EMCP 3 display.Repair: Adjust the generator output voltage to meet site requirements. Resume normal operation and verify that the problem has been corrected.STOP
NOT OK - The generator output voltage cannot be adjusted. Proceed to Test Step 4.Test Step 4. CHECK CAT DATA LINK BETWEEN THE EMCP 3 AND THE VOLTAGE REGULATOR.Refer to the generator set electrical system schematic in the service manual. Check the data link wiring between the EMCP 3 and the voltage regulator. For more information on troubleshooting the data link, refer to Troubleshooting , RENR7902, "Data Link Circuit Fault ".Results:
OK - The data link wiring is correct. Proceed to Test
Determine the conditions that caused the under voltage condition.Expected Result:An under voltage was caused by an occurrence known to the operator. The operator would like to put the generator set back into service.Results:
OK - The operator can determine the cause for the under voltage condition. The condition has been repaired and the operator wants to put the generator set back into service.Repair: Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOP
NOT OK - The under voltage condition was not caused by an occurrence known to the operator. Proceed to Test Step 2.Test Step 2. CHECK THE SET POINTS.
View the following set points:
Generator under voltage
Automatic voltage regulator (AVR) desired voltage request
Generator AC monitorMake a note of the set points. Refer to Testing and Adjusting, RENR7902, "Electronic Control Module (Generator Set) - Configure". Compare the set points against the default set points of the particular generator set.Expected Result:The set points are correct.Results:
OK - The set points are correct for your particular generator set. Proceed to Test Step 3.
NOT OK - The set points are NOT correct.Repair: Reprogram the set points. Reset the generator set. Resume normal operation and verify that the problem has been corrected.STOPTest Step 3. VERIFY VOLTAGE CAN BE ADJUSTED.Verify that the generator output voltage can be adjusted from the EMCP 3 display.Expected Result:The generator output voltage can be adjusted from the EMCP 3 display.Results:
OK - The generator output voltage can be changed from the EMCP 3 display.Repair: Adjust the generator output voltage to meet site requirements. Resume normal operation and verify that the problem has been corrected.STOP
NOT OK - The generator output voltage cannot be adjusted. Proceed to Test Step 4.Test Step 4. CHECK CAT DATA LINK BETWEEN THE EMCP 3 AND THE VOLTAGE REGULATOR.Refer to the generator set electrical system schematic in the service manual. Check the data link wiring between the EMCP 3 and the voltage regulator. For more information on troubleshooting the data link, refer to Troubleshooting , RENR7902, "Data Link Circuit Fault ".Results:
OK - The data link wiring is correct. Proceed to Test
Cat SIS web machinery list:
Parts bolt Caterpillar catalog:
7X0394
BOLT
824G, 824G II, 844, 844H, 854G, 854K, CS-323, D10N, D10R, D11N, D11R
824G, 824G II, 844, 844H, 854G, 854K, CS-323, D10N, D10R, D11N, D11R
1K9415
BOLT
AE40 II, D10, D10N, D10R, D11N, D11R, D11T, D9G, D9N, D9R, D9T
AE40 II, D10, D10N, D10R, D11N, D11R, D11T, D9G, D9N, D9R, D9T
6T8520
BOLT-TRACK MASTER
D11N, D11R, D11T
D11N, D11R, D11T
6T8521
BOLT-TRACK MASTER
D11N, D11R, D11T
D11N, D11R, D11T
7T0998
BOLT-TRACK MASTER
D10N, D10R, D10T
D10N, D10R, D10T
7T0999
BOLT-TRACK MASTER
D10N, D10R, D10T
D10N, D10R, D10T
7T1000
BOLT-TRACK
D10N, D10R, D10T, D10T2
D10N, D10R, D10T, D10T2
7T1243
BOLT
D11N, D11R, D11T
D11N, D11R, D11T
9W7269
BOLT
D11N, D11R, D11T
D11N, D11R, D11T
8T5881
BOLT
D11N, D11R, D11T
D11N, D11R, D11T
5P5422
BOLT
D10, D10N, D10R, D10T, D10T2
D10, D10N, D10R, D10T, D10T2
1T0414
BOLT-12 POINT HEAD
120G, 12G, 130G, 140G, 14E, 14G, 14H, 14H NA, 16, 160G, 16G, 16H, 16H NA, 215, 24H, 24M, 3204, 3208, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 508, 515, 517, 518, 518C, 525, 527, 528, 528B...
120G, 12G, 130G, 140G, 14E, 14G, 14H, 14H NA, 16, 160G, 16G, 16H, 16H NA, 215, 24H, 24M, 3204, 3208, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 508, 515, 517, 518, 518C, 525, 527, 528, 528B...
7H7954
BOLT
12E, 14G, 16, 1673C, 16G, 215, 215B, 225, 235, 235B, 235C, 245, 3304, 3306, 3406, 3406B, 3406C, 3408, 3408B, 3412, 3412E, 3508, 3512, 3516, 518C, 528, 528B, 530B, 54, 583K, 594, 594H, 5S, 631C, 633C, ...
12E, 14G, 16, 1673C, 16G, 215, 215B, 225, 235, 235B, 235C, 245, 3304, 3306, 3406, 3406B, 3406C, 3408, 3408B, 3412, 3412E, 3508, 3512, 3516, 518C, 528, 528B, 530B, 54, 583K, 594, 594H, 5S, 631C, 633C, ...
8B6071
BOLT
3408B, 3412, 3412D, 3412E, 3512, 3512B, C30, C32, SPF343, SPS343, SPT343
3408B, 3412, 3412D, 3412E, 3512, 3512B, C30, C32, SPF343, SPS343, SPT343
7E5075
BOLT
3408B, 3412
3408B, 3412
1501156
BOLT-SPECIAL
16H NA, 24H, 3406B, 3406C, 3406E, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 578, 589, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773...
16H NA, 24H, 3406B, 3406C, 3406E, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 578, 589, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773...
8F8804
BOLT
120, 120B, 12E, 12G, 130G, 140, 140B, 16G, 184, 215, 215B, 225, 227, 235, 235B, 235C, 235D, 245, 245B, 245D, 24H, 24M, 3406B, 3406C, 3406E, 3408B, 3412, 3412E, 3456, 508, 5110B, 518, 528, 621F, 621G, ...
120, 120B, 12E, 12G, 130G, 140, 140B, 16G, 184, 215, 215B, 225, 227, 235, 235B, 235C, 235D, 245, 245B, 245D, 24H, 24M, 3406B, 3406C, 3406E, 3408B, 3412, 3412E, 3456, 508, 5110B, 518, 528, 621F, 621G, ...
1771450
BOLT-SOCKET HEAD
3408B, 3412, 3412C, PM3412, SCT673, SPS342, SPT342
3408B, 3412, 3412C, PM3412, SCT673, SPS342, SPT342
1045603
BOLT
3408B, 3408C, 3412, 3412C, PM3412, SCT673, SPS342, SPT342
3408B, 3408C, 3412, 3412C, PM3412, SCT673, SPS342, SPT342
4P8094
BOLT-POINT HEAD
3412, 3412E, C30, C32
3412, 3412E, C30, C32
0T0284
BOLT
120G, 12E, 140, 14G, 16G, 215, 225, 235, 245, 3304, 3306, 3408B, 3412, 621, 641, 651, 657, 785, 793, 824, 902, 910, 955H, 977H, 994, AP-1050, D11N, D3, D315, D320A, D326F, D330A, D333A, D334, D336, D3...
120G, 12E, 140, 14G, 16G, 215, 225, 235, 245, 3304, 3306, 3408B, 3412, 621, 641, 651, 657, 785, 793, 824, 902, 910, 955H, 977H, 994, AP-1050, D11N, D3, D315, D320A, D326F, D330A, D333A, D334, D336, D3...
4S9002
BOLT-12 POINT HEAD
3406, 3406B, 3408B, 3408C, 3412, 3412C, 776, 777, 824H, 825H, 826H, 950, 992, D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6K LGP, D7G, D8K, D8L, D9H, G3516, G3516B, G3520B, PM...
3406, 3406B, 3408B, 3408C, 3412, 3412C, 776, 777, 824H, 825H, 826H, 950, 992, D3G, D3K XL, D3K2 LGP, D4G, D4K XL, D4K2 XL, D5G, D5K LGP, D5K2 XL, D6K LGP, D7G, D8K, D8L, D9H, G3516, G3516B, G3520B, PM...
4N2955
BOLT-SELF-LOCKING
120G, 12G, 140B, 14G, 1673C, 215, 225, 235, 3160, 3208, 3304, 3304B, 3306, 3306B, 3408B, 3408C, 3412, 3412C, 518, 613B, 627B, 637D, 941, 950, 955L, D4D, D5, D5B, D6C, D6D, D7F, PM3412, SCT673, SPS342,...
120G, 12G, 140B, 14G, 1673C, 215, 225, 235, 3160, 3208, 3304, 3304B, 3306, 3306B, 3408B, 3408C, 3412, 3412C, 518, 613B, 627B, 637D, 941, 950, 955L, D4D, D5, D5B, D6C, D6D, D7F, PM3412, SCT673, SPS342,...