8S3887 BOLT Caterpillar parts
3618, 561C, 58, 69D, 769D, 771D, 773D, 773E, 775D, 775E, 776C, 776D, 777, 777B, 777D, 939, 939C, 941, 955K, 966C, 977K, C18, D4D, D5C, D5C III, D6C
Rating:
Alternative (cross code) number:
CA8S3887
8S-3887
8S3887
CA8S3887
8S-3887
8S3887
Weight: 0.60 pounds 0 kg.
Information:
GRIP LENGTH
241.3
mm
HEAD HEIGHT
9.8
mm
HEX SIZE
19.05
mm
LENGTH
279.4
mm
MATERIAL
Steel 1035 MPa Min Tensile Strength Rc 33-39
THREAD SIZE
.50-13
GENERATOR SET, WINCH,
Compatible equipment models: 8S3887:
Information:
Engine: 3516C (S/N: KEN1-UP)Introduction
This special instruction is a Quick Start Guide to be used in order to clarify the quick start method for the Auto Paralleling units in the field.Single Unit
Illustration 1 g01951599
Prior to running:
Make lead unit jumper selection to enable dead bus closure. Located at terminal strip on street side.
Illustration 2 g01951615
Application Notes:
In single unit mode, the paralleling controller and Basler protective relay can be switched off if desired. The unit will operate similar to a standard gen set. This switch is located behind the EMCP3 near the terminal switch.Island Mode
Illustration 3 g01951602
Prior to running:
Make lead unit jumper selection to enable dead bus closure on ONE UNIT ONLY and interconnect signal wiring (load share line, VAR share line-if applicable, lead-unit-select wiring) between units. Located at terminal strip on street side.Application Notes:
In island mode, GPC (paralleling controller) performs real (kW) and reactive (kVar) load sharing with like units using independent load sharing analog signals. GPC is backwards compatible with legacy units for real power (kW) sharing.
Reactive (kVar) load sharing should be disabled when paralleling with legacy units. The factory default setting in the GPC is set to "disabled".Utility Parallel
Illustration 4 g01951603
Prior to running:
Interconnect wiring to utility breaker auxiliary contact. Generator control system automatically detects utility parallel mode when the utility breaker auxiliary contact is closed.
Verify lead jumper is NOT INSTALLED.
Verify load share lines are NOT interconnected with other units.
Verify GPC is programmed to the desired Baseload level (default is 1825kW)
Verify GPC is programmed to the desired Ramp rate (default is 10kW/sec.)
Verify GPC is programmed to the desired PF control (default is i0.95)Application Notes:
In utility parallel mode, Basler protective relay will perform sync-check to permit generator breaker closure and protects system from faults when in parallel.
UMR reset: TRIP is reset by pressing STOP on EMCP3 (with 86 lockout relay in tripped state). MAJOR ALARM (indicating fuse loss) is reset by pressing RESET on UMR.
Baseload level is controlled by either the Baseload potentiometer or pre-programmed setpoint in the GPC. Selection is made by a two-position switch.EMCP3 Control
Illustration 5 g01951605
Note: Refer to EMCP3 info film for start/stop instructions.RUN Mode
In RUN mode, operator must close breaker using breaker control switch (when running at normal voltage and normal frequency). Manual voltage adjust is allowed.Auto Mode
Illustration 6 g01951607
Local Start/Stop SwitchIn AUTO mode, breaker will automatically close (when running at normal voltage and normal frequency). GPC automatically adjusts voltage and frequency.STOP
Pressing STOP:"Single Unit" and "Island modes" - Breaker will open immediately and engine goes into cooldown."Utility modes" - Generator load will ramp down to 10 percent (of rated), the breaker will then trip open and engine goes into cooldown.General Notes
Remote run request signal can be disabled, if desired, with jumper removal (jumper installed as default).
Generator breaker can be locked out using the breaker control switch pull-to-lock feature.
Reset the 86 lockout relay by first pressing "STOP" on EMCP3.Generator Paralleling Controller (GPC)
Illustration 7 g01951520
"AUTO" lamp - This LED is lit when any of the conditions below are present.
Controller is performing auto synchronization (breaker is open). EMCP3.3 must be in auto mode and the voltage
This special instruction is a Quick Start Guide to be used in order to clarify the quick start method for the Auto Paralleling units in the field.Single Unit
Illustration 1 g01951599
Prior to running:
Make lead unit jumper selection to enable dead bus closure. Located at terminal strip on street side.
Illustration 2 g01951615
Application Notes:
In single unit mode, the paralleling controller and Basler protective relay can be switched off if desired. The unit will operate similar to a standard gen set. This switch is located behind the EMCP3 near the terminal switch.Island Mode
Illustration 3 g01951602
Prior to running:
Make lead unit jumper selection to enable dead bus closure on ONE UNIT ONLY and interconnect signal wiring (load share line, VAR share line-if applicable, lead-unit-select wiring) between units. Located at terminal strip on street side.Application Notes:
In island mode, GPC (paralleling controller) performs real (kW) and reactive (kVar) load sharing with like units using independent load sharing analog signals. GPC is backwards compatible with legacy units for real power (kW) sharing.
Reactive (kVar) load sharing should be disabled when paralleling with legacy units. The factory default setting in the GPC is set to "disabled".Utility Parallel
Illustration 4 g01951603
Prior to running:
Interconnect wiring to utility breaker auxiliary contact. Generator control system automatically detects utility parallel mode when the utility breaker auxiliary contact is closed.
Verify lead jumper is NOT INSTALLED.
Verify load share lines are NOT interconnected with other units.
Verify GPC is programmed to the desired Baseload level (default is 1825kW)
Verify GPC is programmed to the desired Ramp rate (default is 10kW/sec.)
Verify GPC is programmed to the desired PF control (default is i0.95)Application Notes:
In utility parallel mode, Basler protective relay will perform sync-check to permit generator breaker closure and protects system from faults when in parallel.
UMR reset: TRIP is reset by pressing STOP on EMCP3 (with 86 lockout relay in tripped state). MAJOR ALARM (indicating fuse loss) is reset by pressing RESET on UMR.
Baseload level is controlled by either the Baseload potentiometer or pre-programmed setpoint in the GPC. Selection is made by a two-position switch.EMCP3 Control
Illustration 5 g01951605
Note: Refer to EMCP3 info film for start/stop instructions.RUN Mode
In RUN mode, operator must close breaker using breaker control switch (when running at normal voltage and normal frequency). Manual voltage adjust is allowed.Auto Mode
Illustration 6 g01951607
Local Start/Stop SwitchIn AUTO mode, breaker will automatically close (when running at normal voltage and normal frequency). GPC automatically adjusts voltage and frequency.STOP
Pressing STOP:"Single Unit" and "Island modes" - Breaker will open immediately and engine goes into cooldown."Utility modes" - Generator load will ramp down to 10 percent (of rated), the breaker will then trip open and engine goes into cooldown.General Notes
Remote run request signal can be disabled, if desired, with jumper removal (jumper installed as default).
Generator breaker can be locked out using the breaker control switch pull-to-lock feature.
Reset the 86 lockout relay by first pressing "STOP" on EMCP3.Generator Paralleling Controller (GPC)
Illustration 7 g01951520
"AUTO" lamp - This LED is lit when any of the conditions below are present.
Controller is performing auto synchronization (breaker is open). EMCP3.3 must be in auto mode and the voltage
Cat SIS web machinery list:
Parts bolt Caterpillar catalog:
1K9420
BOLT
630A, 651E, 657B, 657E, 768C, 769C, 771C, 773B, 775B, 776C, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789C, 789D, 793B, 793C, 793D, D8L
630A, 651E, 657B, 657E, 768C, 769C, 771C, 773B, 775B, 776C, 776D, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789C, 789D, 793B, 793C, 793D, D8L
5K5922
BOLT
16G, 16H, 16H NA, 518C, 528, 528B, 530B, 613C, 613C II, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 814, 814B, 815B, 824C, 826C, 936, 936F, 950, 950B, 950F, 950F II, 966C, 966D, 9...
16G, 16H, 16H NA, 518C, 528, 528B, 530B, 613C, 613C II, 621, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 814, 814B, 815B, 824C, 826C, 936, 936F, 950, 950B, 950F, 950F II, 966C, 966D, 9...
5P8081
BOLT-LOCKING
120G, 12G, 130G, 14G, 16G, 631E, 631G, 633E II, 637D, 637E, 637G, 639D, 69D, 768C, 769C, 769D, 770, 771C, 771D, 772, 772G, 772G OEM
120G, 12G, 130G, 14G, 16G, 631E, 631G, 633E II, 637D, 637E, 637G, 639D, 69D, 768C, 769C, 769D, 770, 771C, 771D, 772, 772G, 772G OEM
4D8695
BOLT
650B, 651, 69D, 768B, 768C, 769, 769C, 769D, 770, 771C, 771D, 772, 772B, 773, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F, 776, 776C, 776D, 777, 777B, 777D, 777F
650B, 651, 69D, 768B, 768C, 769, 769C, 769D, 770, 771C, 771D, 772, 772B, 773, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F, 776, 776C, 776D, 777, 777B, 777D, 777F
6K7706
BOLT
508, 518, 518C, 528, 528B, 530B, 814, 910, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
508, 518, 518C, 528, 528B, 530B, 814, 910, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
8F3895
BOLT
120G, 12G, 130G, 627, 768C, 776C, 776D, 777D
120G, 12G, 130G, 627, 768C, 776C, 776D, 777D
4D2304
BOLT
120G, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 930, 950, 966C, 966D
120G, 657, 769C, 769D, 771C, 771D, 772, 773B, 773D, 775B, 775D, 776C, 776D, 777, 777D, 784B, 785B, 789B, 793B, 793C, 920, 930, 950, 966C, 966D
5K4301
BOLT
815, 950, 966C
815, 950, 966C
3K0963
BOLT
950, 966C, 980, 980B, 992
950, 966C, 980, 980B, 992
3K1551
BOLT
950, 966C, 966R
950, 966C, 966R
3V4247
BOLT
966C
966C
2G4996
BOLT
773, 773B, 773D, 773E, 776, 777
773, 773B, 773D, 773E, 776, 777
5P4625
BOLT
3618, 943, C32, D10N, D10R, D4H, D4H XL, D4HTSK II, D4HTSK III
3618, 943, C32, D10N, D10R, D4H, D4H XL, D4HTSK II, D4HTSK III
8C3185
BOLT-12 POINT HEAD
3612, 3616, 3618, 572R, 572R II, 583R, C280-12, C280-16, D10R, D11R, D7H, D7R, D7R II, D8N
3612, 3616, 3618, 572R, 572R II, 583R, C280-12, C280-16, D10R, D11R, D7H, D7R, D7R II, D8N
6V8849
BOLT-12 POINT HEAD
3618, 611, 615C, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627E, 627F, 627G, 627H, 627K, 627K LRC, D10N, D10R, D10T, D10T2
3618, 611, 615C, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627E, 627F, 627G, 627H, 627K, 627K LRC, D10N, D10R, D10T, D10T2
8K2694
BOLT-12 POINT HEAD
245, 3618
245, 3618
5P8335
BOLT
3618, 992C, 992D, D11R, D11T
3618, 992C, 992D, D11R, D11T
1438431
BOLT
3618, 824K, 825K, 826K, 834K, 836K, 988K
3618, 824K, 825K, 826K, 834K, 836K, 988K
7K6058
BOLT-12 POINT HEAD
231D, 235D, 30/30, 3406E, 3608, 3618, 517, 518, 527, 528, 528B, 530B, 583T, 611, 613C, 613C II, 613G, 615, 615C, 623B, 633D, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 773G, 773G LRC, 773G OEM, 775G,...
231D, 235D, 30/30, 3406E, 3608, 3618, 517, 518, 527, 528, 528B, 530B, 583T, 611, 613C, 613C II, 613G, 615, 615C, 623B, 633D, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 773G, 773G LRC, 773G OEM, 775G,...
1800155
BOLT
3618
3618
1D4623
BOLT
16, 1693, 235, 245, 3606, 3608, 3612, 3616, 3618, 627, 631C, 657B, 657E, 666, 69D, 7261, 768B, 769, 769C, 769D, 771C, 771D, 772, 773B, 773D, 773E, 775B, 775D, 775E, 824B, 825B, 826B, 834, 977L, 980, 9...
16, 1693, 235, 245, 3606, 3608, 3612, 3616, 3618, 627, 631C, 657B, 657E, 666, 69D, 7261, 768B, 769, 769C, 769D, 771C, 771D, 772, 773B, 773D, 773E, 775B, 775D, 775E, 824B, 825B, 826B, 834, 977L, 980, 9...
3F7147
BOLT
140, 141, 30/30, 3192, 319D L, 319D LN, 320D, 320D GC, 320D L, 320D LRR, 320D RR, 320D2, 320E, 320E L, 320E LN, 320E LRR, 321D LCR, 323D L, 323D LN, 323D SA, 323E L, 324D, 324D L, 324E, 324E L, 324E L...
140, 141, 30/30, 3192, 319D L, 319D LN, 320D, 320D GC, 320D L, 320D LRR, 320D RR, 320D2, 320E, 320E L, 320E LN, 320E LRR, 321D LCR, 323D L, 323D LN, 323D SA, 323E L, 324D, 324D L, 324E, 324E L, 324E L...