7W3468 BOX AS-JUNCTION Caterpillar parts
3126, 3208, 3306, 3406B, 3406C, 3408, 3412, 3508, 3512, 3516
Rating:
Alternative (cross code) number:
CA7W3468
7W-3468
7W3468
CA7W3468
7W-3468
7W3468
Weight: 11 pounds 5 kg.
INDUSTRIAL ENGINE,
Compatible equipment models: 7W3468:
Information:
Procedure
Remove the old Service Meter Group from the machine.
Take note of the color and the number on the ground and signal wires. Disconnect the signal wire and the ground wire from the old Service Meter Group.
The machine model will determine the type of connection terminals. The original connection terminals to the old Service Meter Group will be one of the following:
Separate spade terminals
7N-9738 Receptacle Housing
7Y-3952 Plug Connector
If separate spade terminals are present, proceed to Step 4.a. If 7N-9738 Receptacle Housing is present, proceed to Step 4.b. If a 7Y-3952 Plug connector is present, proceed to Step 4.c.
Illustration 1 g01481384
285-9075302-5812 Service Meter Group - Back View (1) B+ (2) - (3) S
Connect the Signal wire that was removed from the old Service Meter Group to the Terminal (S) on the new Service Meter Group. Connect the negative wire that was removed from the old Service Meter Group to the Terminal (-) (ground) of the new Service Meter Group. Refer to Illustration 1.
Illustration 2 g01482173
285-9075 Service Meter Group - Front viewNote: The 302-5812 Service Meter Group is similar to the 285-9075 Service Meter Group with an additional chrome bezel.
Illustration 3 g01482247
9W-1411 Wire As
Connect a 9W-1411 Wire to the 7N-9738 Receptacle Housing as follows:Note: Make a note of the color and the number of the Ground (-) wire and Signal wire before you disconnect the old Service Meter Group .
Connect the wire that went to the positive terminal of the old Service Meter Group to Terminal "S" (Signal) on the new Service Meter Group. Refer to Illustration 1.
Connect the wire that went to the negative terminal of the old Service Meter Group to Terminal "-" (Ground) on the new Service Meter Group. Refer to Illustration 1.
Illustration 4 g01482286
200-5722 Wire As
Illustration 5 g01482353
7Y-3952 Plug Connector
Connect a 200-5722 Wire As to the 7Y-3952 Plug Connector as follows:
Connect the red wire (male terminal) from the 200-5722 Wire As to the bottom of the 7Y-3952 Plug Connector . Refer to Illustration 4 and Illustration 5.
Connect the black wire (male terminal) from the 200-5722 Wire As to the top of the 7Y-3952 Plug Connector . Refer to Illustration 4 and Illustration 5.
Connect the red wire (female end) from the 200-5722 Wire As to Terminal "S" (Signal) of the new Service Meter Group. Refer to Illustration 1 and Illustration 4.
Connect the black wire (female end) from the 200-5722 Wire As to Terminal "-" (ground) of the new Service Meter Group. Refer to Illustration 1 and Illustration 4.
The unswitched Battery (+) connection is necessary for viewing while the machine is shut down. When the key is in the Off position, this connection is needed in order to view the service meter display. This connection is not necessary for the service meter to properly maintain service hours.
Connect the 200-5719 Wire (provided in the Service Meter Kit ) to the Terminal (+) of the new Service Meter Group. Refer to Illustration 1.
Locate a Battery (+)
Remove the old Service Meter Group from the machine.
Take note of the color and the number on the ground and signal wires. Disconnect the signal wire and the ground wire from the old Service Meter Group.
The machine model will determine the type of connection terminals. The original connection terminals to the old Service Meter Group will be one of the following:
Separate spade terminals
7N-9738 Receptacle Housing
7Y-3952 Plug Connector
If separate spade terminals are present, proceed to Step 4.a. If 7N-9738 Receptacle Housing is present, proceed to Step 4.b. If a 7Y-3952 Plug connector is present, proceed to Step 4.c.
Illustration 1 g01481384
285-9075302-5812 Service Meter Group - Back View (1) B+ (2) - (3) S
Connect the Signal wire that was removed from the old Service Meter Group to the Terminal (S) on the new Service Meter Group. Connect the negative wire that was removed from the old Service Meter Group to the Terminal (-) (ground) of the new Service Meter Group. Refer to Illustration 1.
Illustration 2 g01482173
285-9075 Service Meter Group - Front viewNote: The 302-5812 Service Meter Group is similar to the 285-9075 Service Meter Group with an additional chrome bezel.
Illustration 3 g01482247
9W-1411 Wire As
Connect a 9W-1411 Wire to the 7N-9738 Receptacle Housing as follows:Note: Make a note of the color and the number of the Ground (-) wire and Signal wire before you disconnect the old Service Meter Group .
Connect the wire that went to the positive terminal of the old Service Meter Group to Terminal "S" (Signal) on the new Service Meter Group. Refer to Illustration 1.
Connect the wire that went to the negative terminal of the old Service Meter Group to Terminal "-" (Ground) on the new Service Meter Group. Refer to Illustration 1.
Illustration 4 g01482286
200-5722 Wire As
Illustration 5 g01482353
7Y-3952 Plug Connector
Connect a 200-5722 Wire As to the 7Y-3952 Plug Connector as follows:
Connect the red wire (male terminal) from the 200-5722 Wire As to the bottom of the 7Y-3952 Plug Connector . Refer to Illustration 4 and Illustration 5.
Connect the black wire (male terminal) from the 200-5722 Wire As to the top of the 7Y-3952 Plug Connector . Refer to Illustration 4 and Illustration 5.
Connect the red wire (female end) from the 200-5722 Wire As to Terminal "S" (Signal) of the new Service Meter Group. Refer to Illustration 1 and Illustration 4.
Connect the black wire (female end) from the 200-5722 Wire As to Terminal "-" (ground) of the new Service Meter Group. Refer to Illustration 1 and Illustration 4.
The unswitched Battery (+) connection is necessary for viewing while the machine is shut down. When the key is in the Off position, this connection is needed in order to view the service meter display. This connection is not necessary for the service meter to properly maintain service hours.
Connect the 200-5719 Wire (provided in the Service Meter Kit ) to the Terminal (+) of the new Service Meter Group. Refer to Illustration 1.
Locate a Battery (+)
Caterpillar parts catalog:
Parts box Caterpillar catalog:
8L4236
BOX-CONNECTION
3208, 3304, 3306, D343, D348, D399
3208, 3304, 3306, D343, D348, D399
6I0757
BOX AS-JUNCTION
3508, 3508C, 3512, 3512C, 3516, 3516B, G3304, G3306, G3306B, G3406, G3408, G3412, G3512, G3516
3508, 3508C, 3512, 3512C, 3516, 3516B, G3304, G3306, G3306B, G3406, G3408, G3412, G3512, G3516
3N4420
BOX AS-INSTRUMENT
3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508C, 3512, 3516, 3516B, C-15, C-16, C15, C18, C27, C30, C32, CX31-C15I, CX35-P800, D348, G3508, G3512, G3516, TH...
3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508C, 3512, 3516, 3516B, C-15, C-16, C15, C18, C27, C30, C32, CX31-C15I, CX35-P800, D348, G3508, G3512, G3516, TH...
5N2194
BOX AS-INSTRUMENT
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608
2H1258
BOX-ELECTRICAL
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C32, D342, D349, D353C, D379, D398, D399, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, G3606...
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C32, D342, D349, D353C, D379, D398, D399, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, G3606...
7E5576
BOX AS-PLENUM
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B
5N2091
BOX
3512, 3516
3512, 3516
9Y5988
BOX AS-PLENUM
3512, 3516
3512, 3516
4W5297
BOX AS-INSTRUMENT
3412, 3412C, 3412E
3412, 3412C, 3412E
4370262
BOX AS
3406B
3406B
4P3870
BOX AS
3508, 3512, 3516, 3612, 3616
3508, 3512, 3516, 3612, 3616
4W3925
BOX AS-JUNCTION
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3412D, 3508, 3512, 3516, 3606, 3608, 3612, 3616, G3406, G3408, G3412, G3508, G3512, G3516, G399
3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3412D, 3508, 3512, 3516, 3606, 3608, 3612, 3616, G3406, G3408, G3412, G3508, G3512, G3516, G399
5Y0348
BOX GP-TERMINAL
3408B
3408B
2496240
BOX & MOUNTING GP
330C L
330C L
2140388
BOX & MOUNTING GP
330C L
330C L
1519808
BOX GP-STORAGE
320B U
320B U
1524871
BOX-STORAGE
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 247, 247B, 247B3, 248, 252B, 252B3, 257B, 257B3, 259B3, 267, 267B, 268B, 287, C15, C15 I6, C18, C18 I6, C4.4, C9, CB-22, CB-34,...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 247, 247B, 247B3, 248, 252B, 252B3, 257B, 257B3, 259B3, 267, 267B, 268B, 287, C15, C15 I6, C18, C18 I6, C4.4, C9, CB-22, CB-34,...
1743721
BOX-PUSH OFF
TH82
TH82
1743701
BOX-GRAB
TH82
TH82
8I6063
BOX AS
TH82
TH82
1180742
BOX AS-BATTERY
35, 45, 55
35, 45, 55
9R6517
BOX AS
416, 416B, 426, 428B
416, 416B, 426, 428B