Illustration 1 g01135875
Schematic of the Boom Lowering Check SolenoidThis diagnostic code is associated with the Boom Lowering Check Solenoid. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1149 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code of CID 1149 FMI 03 will be logged in the internal memory of the Machine ECM.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-58 (wire P944-GY) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-58 (P944-GY) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1149 FMI 03 is active.Expected Result:The CID 1149 FMI 03 is active.Results:
YES - The CID 1149 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 1149 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. Stop.
Caterpillar parts catalog:
Parts brace Caterpillar catalog:
3848049
BRACE-RADIATOR
C13 XQ350
C13 XQ350
3848050
BRACE-RADIATOR
C13 XQ350
C13 XQ350
3651049
BRACE
C13 XQ350
C13 XQ350
3848050
BRACE-RADIATOR
C13 XQ350
C13 XQ350
3848049
BRACE-RADIATOR
C13 XQ350
C13 XQ350
3565635
BRACE AS
C27
C27
3689139
BRACE AS
C27
C27
9N6661
BRACE
G3408, G3412
G3408, G3412
3764152
BRACE
C7.1
C7.1
9L8994
BRACE
1160
1160
2N3590
BRACE
3150, 3160
3150, 3160
2N0200
BRACE
225, 3160
225, 3160
3651049
BRACE
C13 XQ350
C13 XQ350