1968237 BRACKET Caterpillar parts
311C, 312C, 312C L, 314C, 315C, 320B, D3G, D4G, D5G
Rating:
Alternative (cross code) number:
CA1968237
196-8237
1968237
CA1968237
196-8237
1968237
Weight: 1 pounds 0 kg.
EXCAVATOR, TRACK-TYPE TRACTOR,
Compatible equipment models: 1968237:
Information:
System Operation Description:There are problems that could be reported with the Product Link System but the problems are not caused by the Product Link Module. The following section describes the problems. The section contains steps that are used to determine the possible cause. Check for active diagnostic codes for the Product Link. Correct any diagnostic codes before proceeding. The module, the antenna, and cables should be visually inspected for damage. Verify that there are no loose connections.Description of the Problem:
The intervals between reports are erratic. The Product Link system depends on several communication links in order to transfer data from the machine to the office. The following procedures assume that these communication links are operating properly. The proper Communication links are listed below:
The Orbcomm satellite network is operational in the geographic area of concern. The network is operational when messages can travel to the satellite and the messages can travel to the earth and Caterpillar.
The Product Link module is correctly configured to communicate on the Orbcomm network. This was verified during manufacturing tests.
The worldwide network of Caterpillar's computers is passing messages to the software ("CPLS-Web: Caterpillar Product Link System - PC Software").
The CPLS is configured properly and the software is functioning.The Product Link module should not be replaced without verifying that these issues have been investigated. Contact the Service System Support Center for aid in resolving these issues.Test Step 1. CHECK THE LED INDICATORS.Check the LED indicators on the Product Link. Expected Result:The red LED is OFF.Results:
RED LED OFF - The red LED is OFF. There are no diagnostic codes. Proceed to Test Step 2.
RED LED BLINKING - The red LED is blinking. There is a diagnostic code.Repair: First correct the diagnostic code. See Troubleshooting, "Diagnostic Code List" for more information. Stop.
RED LED ALWAYS ON - The red LED is always ON. The Product Link has failed.Repair: Replace the Product Link. Stop.Test Step 2. ACCESS THE PRODUCT LINK THROUGH THE ELECTRONIC TECHNICIAN.
Connect the Electronic Technician to the machine.
Verify that the ECM (Product Link) is available.Expected Result:The ECM (Product Link) is available.Results:
OK - The ECM (Product Link) is available. Proceed to Test Step 3.
NOT OK - The ECM (Product Link) is not present in the Electronic Technician screen. Repair: Verify that the wiring for the Product Link has been installed correctly. See Systems Operation, "System Installation". Near the end of the installation procedure, Step 13 checks the wiring with a multimeter. If the ECM (Product Link) is not available, see Troubleshooting, "Electronic Service Tool Does Not Communicate with ECM". Stop.Test Step 3. VERIFY THAT THE PRODUCT LINK HAS NOT BEEN TURNED OFF.
Go to "ET Status Group 2 - PLM Operational Status".
Verify that the" Possible Device Power Disconnection" is labelled as "No".Expected Result:"Possible Device Power Disconnection" is labelled as "No".Results:
OK - The "Possible Device Power Disconnection" is labelled as "No". The Product Link has operated since successfully transmitting the last report. Proceed to Test Step 4.
NOT OK - "Possible Device Power Disconnection" is labelled as "Yes". The Product Link has
The intervals between reports are erratic. The Product Link system depends on several communication links in order to transfer data from the machine to the office. The following procedures assume that these communication links are operating properly. The proper Communication links are listed below:
The Orbcomm satellite network is operational in the geographic area of concern. The network is operational when messages can travel to the satellite and the messages can travel to the earth and Caterpillar.
The Product Link module is correctly configured to communicate on the Orbcomm network. This was verified during manufacturing tests.
The worldwide network of Caterpillar's computers is passing messages to the software ("CPLS-Web: Caterpillar Product Link System - PC Software").
The CPLS is configured properly and the software is functioning.The Product Link module should not be replaced without verifying that these issues have been investigated. Contact the Service System Support Center for aid in resolving these issues.Test Step 1. CHECK THE LED INDICATORS.Check the LED indicators on the Product Link. Expected Result:The red LED is OFF.Results:
RED LED OFF - The red LED is OFF. There are no diagnostic codes. Proceed to Test Step 2.
RED LED BLINKING - The red LED is blinking. There is a diagnostic code.Repair: First correct the diagnostic code. See Troubleshooting, "Diagnostic Code List" for more information. Stop.
RED LED ALWAYS ON - The red LED is always ON. The Product Link has failed.Repair: Replace the Product Link. Stop.Test Step 2. ACCESS THE PRODUCT LINK THROUGH THE ELECTRONIC TECHNICIAN.
Connect the Electronic Technician to the machine.
Verify that the ECM (Product Link) is available.Expected Result:The ECM (Product Link) is available.Results:
OK - The ECM (Product Link) is available. Proceed to Test Step 3.
NOT OK - The ECM (Product Link) is not present in the Electronic Technician screen. Repair: Verify that the wiring for the Product Link has been installed correctly. See Systems Operation, "System Installation". Near the end of the installation procedure, Step 13 checks the wiring with a multimeter. If the ECM (Product Link) is not available, see Troubleshooting, "Electronic Service Tool Does Not Communicate with ECM". Stop.Test Step 3. VERIFY THAT THE PRODUCT LINK HAS NOT BEEN TURNED OFF.
Go to "ET Status Group 2 - PLM Operational Status".
Verify that the" Possible Device Power Disconnection" is labelled as "No".Expected Result:"Possible Device Power Disconnection" is labelled as "No".Results:
OK - The "Possible Device Power Disconnection" is labelled as "No". The Product Link has operated since successfully transmitting the last report. Proceed to Test Step 4.
NOT OK - "Possible Device Power Disconnection" is labelled as "Yes". The Product Link has
Caterpillar parts catalog:
Parts bracket Caterpillar catalog:
5I7722
BRACKET
311, 311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 320N, 321C, 323D L, 323D LN
311, 311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 320N, 321C, 323D L, 323D LN
1653065
BRACKET-MIRROR
312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320...
312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320...
1864682
BRACKET
308C, 314C
308C, 314C
1140624
BRACKET AS
320B, 322B L, 322B LN, 325B, 325B L, 330B L, M325B, W330B
320B, 322B L, 322B LN, 325B, 325B L, 330B L, M325B, W330B
1765005
BRACKET
320B, 321B
320B, 321B
1262987
BRACKET AS
320B, 320B U
320B, 320B U
1190627
BRACKET AS
320B, 320C, 321B, 323D L, 323D LN
320B, 320C, 321B, 323D L, 323D LN
5I7647
BRACKET
320 L, 320B, 320B L, 320C, 320C FM, 320N
320 L, 320B, 320B L, 320C, 320C FM, 320N
1352345
BRACKET
320B, 320B L, 320N
320B, 320B L, 320N
1023773
BRACKET AS
320 L, 320B, 320N
320 L, 320B, 320N
1540446
BRACKET AS
320B
320B
1597751
BRACKET AS
320B
320B
1968239
BRACKET
311C, 312C L
311C, 312C L
1968216
BRACKET
311C, 312C, 312C L, 314C
311C, 312C, 312C L, 314C
1958834
BRACKET AS
312C, 312C L
312C, 312C L
1968014
BRACKET
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR
1968012
BRACKET
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 313D, 314C, 314D CR, 314D LCR
1968191
BRACKET AS
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM RR, 320D LRR, 320D RR, 321C, 321D LCR, 323D L, 323D LN
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D FM RR, 320D LRR, 320D RR, 321C, 321D LCR, 323D L, 323D LN
2797532
BRACKET AS
312C L
312C L
2797535
BRACKET AS
312C L
312C L
2705433
BRACKET
311C, 311D LRR, 312C L, 312D, 315C, 315D L, 318C, 319D, 319D L, 320C, 320C FM, 320D, 320D L, 320D LRR, 320D RR, 323D L, 323D LN, 324D, 324D L, 324D LN, 325D, 325D L, 329D L, 330D, 330D L, 330D LN, 336...
311C, 311D LRR, 312C L, 312D, 315C, 315D L, 318C, 319D, 319D L, 320C, 320C FM, 320D, 320D L, 320D LRR, 320D RR, 323D L, 323D LN, 324D, 324D L, 324D LN, 325D, 325D L, 329D L, 330D, 330D L, 330D LN, 336...
2041901
BRACKET AS
311C, 312C, 312C L, 314C
311C, 312C, 312C L, 314C
1905906
BRACKET
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
2128509
BRACKET
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
311C, 312C, 312C L, 314C, 318C, 319C, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN