When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters.If a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters.If a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.
Caterpillar parts catalog:
Parts bracket Caterpillar catalog:
2344836
BRACKET
236B, 246C, 252B, 256C, 262C, 267B, 268B, 272C, 277C, 287C, 297C, 3044C, 906, 906H, 907H, 908, 908H
236B, 246C, 252B, 256C, 262C, 267B, 268B, 272C, 277C, 287C, 297C, 3044C, 906, 906H, 907H, 908, 908H
2947916
BRACKET
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 906, 906H, 907H, 908, 908H
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 906, 906H, 907H, 908, 908H
2176222
BRACKET AS
902, 906, 908
902, 906, 908
2176223
BRACKET AS
902, 906, 908
902, 906, 908
2282480
BRACKET AS
902, 906, 908
902, 906, 908
1522621
BRACKET AS
902, 906, 908
902, 906, 908
3116321
BRACKET
906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
2305668
BRACKET
906
906
2287670
BRACKET AS
906, 908
906, 908
2287669
BRACKET AS
906, 908
906, 908
2320478
BRACKET AS
906, 906H, 907H, 908, 908H
906, 906H, 907H, 908, 908H
2304819
BRACKET AS
906, 908
906, 908
3303667
BRACKET AS
906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
906, 906H, 906H2, 907H, 907H2, 908, 908H, 908H2
2366121
BRACKET
914G, IT14G, IT14G2
914G, IT14G, IT14G2
2366120
BRACKET
914G, IT14G, IT14G2
914G, IT14G, IT14G2
2790726
BRACKET
906, 908
906, 908