2888736 BRACKET-YM Caterpillar parts
Rating:
Alternative (cross code) number:
CA2888736
288-8736
2888736
CA2888736
288-8736
2888736
Weight: 66 pounds 29 kg.
Related part:
8W4067
BRACKET-YM
2888736
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Table 3
Temperature Range "T2" (Low)
Temperature (°F) Ohms (Ω) Volts (V)
188 64.07 0.6250
174 69.09 0.9975
165 74.12 1.2500
158 79.16 1.5675
150 84.20 1.8750
142 89.25 2.1875
138 94.31 2.5000
135 99.37 2.8125
132 104.50 3.1250
129 109.50 3.4375
126 114.60 3.7500
123 119.70 4.0625
120 124.80 4.3750 Note: If the fan remains in NEUTRAL and the engine is hot, disconnect the temperature sensor in order to temporarily solve the problem. The controller automatically places the fan into full pitch if the temperature sensor is disconnected. Purge cycles will continue normally, but the fan will not go into NEUTRAL when the engine is cold. The temperature sensor can be disconnected until the problem is rectified.ECM Controlled System Troubleshooting
Note: For additional information for troubleshooting your ECM controlled system, refer to the electrical schematic for your machine.Diagnostic Codes
When the hydraulic actuated fan is enabled, the ECM will check the diagnostics for the solenoid valve. See Table 4 for diagnostic codes that may be generated.
Table 4
Diagnostic Codes
Description Code
The “PULL” Solenoid has an open circuit or a short circuit to the + battery. 1599-05
The “PULL” Solenoid has a short circuit to the ground. 1599-06
The “PUSH” Solenoid has an open circuit or a short circuit to the + battery. 1600-05
The “PUSH” Solenoid has a short circuit to the ground. 1600-06 Troubleshooting
Problem 1: Electronic technician shows that the fan blade cooling position is set to PUSH, but the fan is in PULL.
Cause 1: Wires are incorrectly positioned in a connector.Solution 1: Check the positions of the wires and compare the positions to the schematic for the machine.Cause 2: Hydraulic lines are reversed.Solution 2: Make sure that the lines are connected correctly.Problem 2: Electronic Technician shows a fault code of NO SPEED SIGNAL on D9R.
Cause 1: On D9R (S/N: ABK; ACL), the fan speed solenoid is "ON".Solution 1: Turn the fan speed solenoid to "OFF". Make sure that the variable pitch fan is enabled.Problem 3: The fan does not purge at the timed interval. The fan purges when the manual purge switch is pressed.
Cause 1: Purge suspend is enabled.Solution 1: Check the ECM in order to determine if purge suspend is enabled. If purge suspend is enabled, check the timed purge when the machine is in REVERSE.Cause 2: The signal wire is broken from the transmission or from the backup alarm.Solution 2: Check the signal wire for continuity. Check the signal wire for voltage when the transmission is in REVERSE.Cause 3: The ECM failed.Solution 3: Check the ECM with the electronic technician in order to determine if the time until the next purge is decreasing. When time equals zero, the ECM should initiate a purge cycle.Problem 4: The fan purges at the timed interval. The fan does not purge when the manual purge switch is pushed.
Cause 1: The manual purge switch is disabled.Solution 1: Enable the manual purge switch with the electronic technician.Cause 2: The signal wire
Parts bracket Caterpillar catalog:
2888735
BRACKET-YM
Caterpillar
Caterpillar
2888734
BRACKET-YM
Caterpillar
Caterpillar
2888733
BRACKET AS-YM
Caterpillar
Caterpillar
2888732
BRACKET AS-YM
Caterpillar
Caterpillar
2977149
BRACKET-YM
Caterpillar
Caterpillar
2977147
BRACKET-YM
Caterpillar
Caterpillar
0006239
BRACKET
Caterpillar
Caterpillar
0006091
BRACKET
Caterpillar
Caterpillar
0006047
BRACKET A
Caterpillar
Caterpillar
0005922
BRACKET
Caterpillar
Caterpillar
2260212
BRACKET-TRK-YM
Caterpillar
Caterpillar
2260211
BRACKET-YM
Caterpillar
Caterpillar