Illustration 2 g02202815
Typical Cat ET screen for logged events
An indicator for logged events is provided. The indicator allows the service technician to track event codes that are intermittent. The data for the logged event will include the following information:
An Event Identifier (EID)
A text description of the problem
The number of occurrences of the problem
A time stamp will display the first occurrence of the problem.
A time stamp will display the last occurrence of the problem.Status Groups For Cat ET
The Status groups are lists of machine parameters. The status is shown in real time.
Illustration 3 g02204894
Typical Cat ET Status Screen
Configure the VIMS 3G Outputs
Use Cat ET in order to configure the outputs for VIMS.Procedure
Connect a laptop computer with Cat ET to the service connector of the machine via the communication adapter.
Turn the disconnect key and the key start switch to the ON position.
Start Cat ET and establish communication with the machine.
Illustration 4 g00895412
Select "Service".
Illustration 5 g00895419
Select "Configuration F5".
Select the "Configuration" option of the "Service" menu or press the "F5" key. The "Configuration" screen will be displayed. Refer to Illustration 6.
Illustration 6 g01207504
Configuration screen (Typical)
Select the parameter. You may configure the output diagnostics for the parameters that are listed in Table 1.
Table 1
Output Parameters of the VIMS 3G Application ECM
Description Values
"Front Axle Strut Pressure to Payload Weight Ratio Configuration" "XXXX"(1)
"Empty Machine Wt" "xxx.xxx"(2)
"Empty Machine Rear Axle Weight Distribution" "xx.x"(2)
"Loaded Machine Rear Axle Weight Distribution" "xx.x"(2)
"Machine Tire Weight-Speed Machine Speed Limit" "xx.x"(2)
"Machine Weight-Speed Averaging Duration" "x"(2)
"Machine Speed Limit Activation Front Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Deactivation Front Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Activation Rear Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Deactivation Rear Tires Weight-Speed Threshold" "xxxx"(2)
"Green TPMS Lamp Installation Configuration" "Installed"
"Incandescent lamp"
"LED"
"Red TPMS Lamp Installation Configuration" "Installed"
"Incandescent lamp"
"LED"
Tire Analysis System Installation Status Not Installed
Road Analysis System Installation Status Not Installed
Road Analysis Severity Selection "0"
(1) The values for each model are the standard value. Do not adjust the values unless you have authorization.
(2) These values are configurable only if "TKPH" is activated through the attachment code.
Click on the "Change" button that is located on the "Configuration" screen. A dialog box will be displayed.
Illustration 7 g01967694
Click on the down arrow on the right-hand side of the dialog box. The settings that are available for the parameter will be displayed.
Highlight the new value and click on the "OK" button. Cat ET will display the following message:
Illustration 8 g01961187
Click on the "Yes" button in order to change the parameter setting. Click on the "No" button in order to cancel the change of the parameter setting.
Logged Event Codes
Illustration 2 g02202815
Typical Cat ET screen for logged events
An indicator for logged events is provided. The indicator allows the service technician to track event codes that are intermittent. The data for the logged event will include the following information:
An Event Identifier (EID)
A text description of the problem
The number of occurrences of the problem
A time stamp will display the first occurrence of the problem.
A time stamp will display the last occurrence of the problem.Status Groups For Cat ET
The Status groups are lists of machine parameters. The status is shown in real time.
Illustration 3 g02204894
Typical Cat ET Status Screen
Configure the VIMS 3G Outputs
Use Cat ET in order to configure the outputs for VIMS.Procedure
Connect a laptop computer with Cat ET to the service connector of the machine via the communication adapter.
Turn the disconnect key and the key start switch to the ON position.
Start Cat ET and establish communication with the machine.
Illustration 4 g00895412
Select "Service".
Illustration 5 g00895419
Select "Configuration F5".
Select the "Configuration" option of the "Service" menu or press the "F5" key. The "Configuration" screen will be displayed. Refer to Illustration 6.
Illustration 6 g01207504
Configuration screen (Typical)
Select the parameter. You may configure the output diagnostics for the parameters that are listed in Table 1.
Table 1
Output Parameters of the VIMS 3G Application ECM
Description Values
"Front Axle Strut Pressure to Payload Weight Ratio Configuration" "XXXX"(1)
"Empty Machine Wt" "xxx.xxx"(2)
"Empty Machine Rear Axle Weight Distribution" "xx.x"(2)
"Loaded Machine Rear Axle Weight Distribution" "xx.x"(2)
"Machine Tire Weight-Speed Machine Speed Limit" "xx.x"(2)
"Machine Weight-Speed Averaging Duration" "x"(2)
"Machine Speed Limit Activation Front Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Deactivation Front Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Activation Rear Tires Weight-Speed Threshold" "xxxx"(2)
"Machine Speed Limit Deactivation Rear Tires Weight-Speed Threshold" "xxxx"(2)
"Green TPMS Lamp Installation Configuration" "Installed"
"Incandescent lamp"
"LED"
"Red TPMS Lamp Installation Configuration" "Installed"
"Incandescent lamp"
"LED"
Tire Analysis System Installation Status Not Installed
Road Analysis System Installation Status Not Installed
Road Analysis Severity Selection "0"
(1) The values for each model are the standard value. Do not adjust the values unless you have authorization.
(2) These values are configurable only if "TKPH" is activated through the attachment code.
Click on the "Change" button that is located on the "Configuration" screen. A dialog box will be displayed.
Illustration 7 g01967694
Click on the down arrow on the right-hand side of the dialog box. The settings that are available for the parameter will be displayed.
Highlight the new value and click on the "OK" button. Cat ET will display the following message:
Illustration 8 g01961187
Click on the "Yes" button in order to change the parameter setting. Click on the "No" button in order to cancel the change of the parameter setting.
Caterpillar parts catalog:
Parts bracket Caterpillar catalog:
2498606
BRACKET
C32
C32
2509149
BRACKET
980H, C13, C32
980H, C13, C32
3003952
BRACKET
C32
C32
2982014
BRACKET
C32
C32
1326782
BRACKET
5110B, 773B, 773D, 773E, 775B, 793C, 844, 854G, 990, 990 II, 992G, C27, C32
5110B, 773B, 773D, 773E, 775B, 793C, 844, 854G, 990, 990 II, 992G, C27, C32
3464231
BRACKET-ISOLATOR
C18, C32
C18, C32
3283477
BRACKET
C32
C32
3464248
BRACKET
C32
C32
3308964
BRACKET
C32
C32
3185190
BRACKET
C32
C32
3464248
BRACKET
C32
C32
3464247
BRACKET
C32
C32
3464246
BRACKET
C32
C32
3464244
BRACKET
C32
C32