4361113 BRACKET Caterpillar parts
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
Rating:
Alternative (cross code) number:
CA4361113
436-1113
4361113
CA4361113
436-1113
4361113
Weight: 0.25 pounds 0 kg.
COMPACT TRACK LOADER, SKID STEER LOADER,
Compatible equipment models: 4361113:
Information:
Manual control of the outputsNormally, the lubrication pump is in "Automatic" mode. If you select the "Manual" radio button that is above the lights, you can place the outputs under manual control.Three check boxes appear below the lights. If you select the check boxes you can engage the following components. If you unselect the check boxes you can disengage the following components: the pump motor, the solenoid valve and the signal light.Note: When the ignition is switched off, the operating mode will automatically revert to "Automatic" mode. Note: When the "Manual" mode is selected, all activated outputs will be adopted.Performing a single cycle testBy selecting the "Single cycle" radio button that is above the lights, you can initiate a single cycle test.Note: The operating mode will automatically revert to "Automatic" when the ignition is switched off.Note: A test cycle cannot be initiated while the system is performing a pump phase.To perform a single cycle test, perform the following.
Select the Single cycle radio button. The lights in the Diagnosis window and the signal lamp will start to blink slowly.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights. When the test is completed, the operating mode will automatically revert to "Automatic". Performing a multiple cycle testBy selecting the "Multiple cycle" radio button that is above the lights, you can initiate a multiple cycle test.Note: The operating mode will automatically revert to "Automatic" when the ignition is switched off.Note: A test cycle cannot be initiated while the system is performing a pump phase.To perform a Multiple cycle test, perform the following.
Select the Multiple cycle radio button. The lights in the Diagnosis window and the signal lamp will start to blink quickly.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights.
Select the "Automatic" or "Manual" radio button in order to stop the multiple cycle test. Note: During a multiple cycle test, the pressure retaining phase and the pause phases between the cycles "A" and cycles "B" will be skipped.Checking the functioning of the test button on the lubrication pumpTo check the functioning of the test button on the lubrication pump, perform the following.
Press the test button on the lubrication pump and keep the test button pressed for 3 seconds in order to perform a single cycle test. Keep the test button pressed for 7 seconds in order to perform a multiple cycle test.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights in the "Diagnosis" tab.
Select the "Automatic" or "Manual" radio buttons in order to stop a multiple cycle test. When a single cycle test is completed, the operating mode will automatically revert to "Automatic".Control Unit
Illustration 11 g01085034
Control unit
The lubrication system is controlled by the electronic control unit. All of the system parameters are stored inside the control unit. The lubrication system can be altered if the operator changes the parameters that are set in the control unit. The control unit
Select the Single cycle radio button. The lights in the Diagnosis window and the signal lamp will start to blink slowly.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights. When the test is completed, the operating mode will automatically revert to "Automatic". Performing a multiple cycle testBy selecting the "Multiple cycle" radio button that is above the lights, you can initiate a multiple cycle test.Note: The operating mode will automatically revert to "Automatic" when the ignition is switched off.Note: A test cycle cannot be initiated while the system is performing a pump phase.To perform a Multiple cycle test, perform the following.
Select the Multiple cycle radio button. The lights in the Diagnosis window and the signal lamp will start to blink quickly.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights.
Select the "Automatic" or "Manual" radio button in order to stop the multiple cycle test. Note: During a multiple cycle test, the pressure retaining phase and the pause phases between the cycles "A" and cycles "B" will be skipped.Checking the functioning of the test button on the lubrication pumpTo check the functioning of the test button on the lubrication pump, perform the following.
Press the test button on the lubrication pump and keep the test button pressed for 3 seconds in order to perform a single cycle test. Keep the test button pressed for 7 seconds in order to perform a multiple cycle test.
Monitor the inputs and outputs of the control unit during the test cycle by watching the lights in the "Diagnosis" tab.
Select the "Automatic" or "Manual" radio buttons in order to stop a multiple cycle test. When a single cycle test is completed, the operating mode will automatically revert to "Automatic".Control Unit
Illustration 11 g01085034
Control unit
The lubrication system is controlled by the electronic control unit. All of the system parameters are stored inside the control unit. The lubrication system can be altered if the operator changes the parameters that are set in the control unit. The control unit
Caterpillar parts catalog:
Parts bracket Caterpillar catalog:
3074479
BRACKET AS
308E2 CR, A26B
308E2 CR, A26B
4191269
BRACKET AS
308E2 CR
308E2 CR
4152608
BRACKET
308E2 CR
308E2 CR
4516823
BRACKET AS
308E2 CR
308E2 CR
4224630
BRACKET AS
308E2 CR
308E2 CR
4190152
BRACKET AS
308E2 CR
308E2 CR
4352992
BRACKET AS
308E2 CR
308E2 CR
4199614
BRACKET AS
308E2 CR
308E2 CR
4199615
BRACKET AS
308E2 CR
308E2 CR
4231870
BRACKET AS
308E2 CR
308E2 CR
4199744
BRACKET
308E2 CR
308E2 CR
4199598
BRACKET AS
308E2 CR
308E2 CR
3979954
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 906H2, 907H2, 908H2
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 906H2, 907H2, 908H2
3871159
BRACKET
236D, 242D, 257D, 259D
236D, 242D, 257D, 259D
4361110
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
4501132
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
4501131
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
4501130
BRACKET AS
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D
3454814
BRACKET AS
236D, 242D, 257D, 259D
236D, 242D, 257D, 259D
4361608
BRACKET AS
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
3967201
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
4361903
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
3967208
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
3902764
BRACKET
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 910K, 914K, 924H, 924HZ, 924K, 930K, 938K, 950 GC, AP-600D, AP-655D, AP1055E, AP555E, BG500E, BG655D, CB-44B...
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 910K, 914K, 924H, 924HZ, 924K, 930K, 938K, 950 GC, AP-600D, AP-655D, AP1055E, AP555E, BG500E, BG655D, CB-44B...