Information:
Conditions Which Generate This Code:
Illustration 1 g00531689
System Schematic For The Relay Driver Module (RDM) Data LinkThe GSC+ communicates with the relay driver module (RDM) by a serial data link. When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays R2 through R9 may maintain the current state. Also, the relays may default to the OFF position. These steps are controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs (R2 through R9) will maintain the states that the relays are currently in. If the jumper is present, R2 through R9 will default to OFF.Note: The maximum distance between a module and the GSC+ is 305 m (1000 ft). If this specification is not met, the data link may malfunction. The GSC+ may show a CID 475. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC+.The possible cause of a CID 0475 FMI 03 is a short to the battery positive terminal.The GSC+ is not able to detect an open circuit condition of the relay driver module (RDM) data link. Clear the diagnostic code from the fault log after the troubleshooting is complete.Test Step 1. CHECK THE VOLTAGE OF THE DATA SIGNAL.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead).Expected Result:The voltage will vary from 0 DCV to 10 DCV.Results:
OK - The voltage varies from 0 DCV to 10 DCV. The voltage is correct. Proceed to test step 4.
NOT OK - The voltage does NOT vary from 0 DCV to 10 DCV. The voltage is NOT correct. Proceed to test step 2.Test Step 2. CHECK THE VOLTAGE OF THE RDM.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC+.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Expected Result:The voltage is 11.6 0.5 DCV. Results:
OK - The voltage is 11.6 0.5 DCV. The voltage is correct. Proceed to test step 3.
NOT OK - The voltage is NOT 11.6 0.5 DCV. The voltage at the RDM is NOT correct. Repair: Replace the RDM.STOPTest Step 3. CHECK THE VOLTAGE OF THE GSC+.
All wires from terminal 4 of the RDM remain disconnected.
The harness connector from the GSC+ remains disconnected.
Measure the DC voltage from contact 30 of the GSC+ to the battery negative terminal of the relay module. The relay module is located on the rear of the GSC+. Expected Result:The voltage varies between 0 DCV to 5.5 DCV.Results:
OK - The voltage varies between 0 DCV to 5.5 DCV. The voltage is correct. Proceed to test step 4.
NOT OK - The voltage does NOT vary between 0 DCV to 5.5 DCV. The voltage is NOT correct.Repair: The GSC+ may have failed. It
Illustration 1 g00531689
System Schematic For The Relay Driver Module (RDM) Data LinkThe GSC+ communicates with the relay driver module (RDM) by a serial data link. When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays R2 through R9 may maintain the current state. Also, the relays may default to the OFF position. These steps are controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs (R2 through R9) will maintain the states that the relays are currently in. If the jumper is present, R2 through R9 will default to OFF.Note: The maximum distance between a module and the GSC+ is 305 m (1000 ft). If this specification is not met, the data link may malfunction. The GSC+ may show a CID 475. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC+.The possible cause of a CID 0475 FMI 03 is a short to the battery positive terminal.The GSC+ is not able to detect an open circuit condition of the relay driver module (RDM) data link. Clear the diagnostic code from the fault log after the troubleshooting is complete.Test Step 1. CHECK THE VOLTAGE OF THE DATA SIGNAL.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead).Expected Result:The voltage will vary from 0 DCV to 10 DCV.Results:
OK - The voltage varies from 0 DCV to 10 DCV. The voltage is correct. Proceed to test step 4.
NOT OK - The voltage does NOT vary from 0 DCV to 10 DCV. The voltage is NOT correct. Proceed to test step 2.Test Step 2. CHECK THE VOLTAGE OF THE RDM.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC+.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Expected Result:The voltage is 11.6 0.5 DCV. Results:
OK - The voltage is 11.6 0.5 DCV. The voltage is correct. Proceed to test step 3.
NOT OK - The voltage is NOT 11.6 0.5 DCV. The voltage at the RDM is NOT correct. Repair: Replace the RDM.STOPTest Step 3. CHECK THE VOLTAGE OF THE GSC+.
All wires from terminal 4 of the RDM remain disconnected.
The harness connector from the GSC+ remains disconnected.
Measure the DC voltage from contact 30 of the GSC+ to the battery negative terminal of the relay module. The relay module is located on the rear of the GSC+. Expected Result:The voltage varies between 0 DCV to 5.5 DCV.Results:
OK - The voltage varies between 0 DCV to 5.5 DCV. The voltage is correct. Proceed to test step 4.
NOT OK - The voltage does NOT vary between 0 DCV to 5.5 DCV. The voltage is NOT correct.Repair: The GSC+ may have failed. It
Cat SIS web machinery list:
Parts bracket Caterpillar catalog:
6K4935
BRACKET
225, 3208, 3304, 3306, 3406B, 3408, 3412, 3508, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 561D, 621, 621B, 621E, 621F, 621G, 621R, 623B, 623E, 623F, 623G, 627B, 627E, 627F, 627G,...
225, 3208, 3304, 3306, 3406B, 3408, 3412, 3508, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 561D, 621, 621B, 621E, 621F, 621G, 621R, 623B, 623E, 623F, 623G, 627B, 627E, 627F, 627G,...
3N4082
BRACKET
215, 229, 245, 3208, 3304, 3406, 3412, 815B, 920, 941, 943, 955L, 963, 980F, D4H, D5H, D7G, G936
215, 229, 245, 3208, 3304, 3406, 3412, 815B, 920, 941, 943, 955L, 963, 980F, D4H, D5H, D7G, G936
1W8795
BRACKET
3304, 3306, 3406, 3408, 3412, 3508, 3512, 589, AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, D10N, D10R, D10T, D10T2, D11R, D11T, D8L, D9L, D9N, D9R, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G,...
3304, 3306, 3406, 3408, 3412, 3508, 3512, 589, AD30, AD45, AD45B, AD55, AD55B, AD60, AE40 II, D10N, D10R, D10T, D10T2, D11R, D11T, D8L, D9L, D9N, D9R, R1300G, R1300G II, R1600, R1600G, R1600H, R1700G,...
1891918
BRACKET
3176C, 3406B, 3406C, 3406E, 3456, C-10, C-12, C-15, C-16
3176C, 3406B, 3406C, 3406E, 3456, C-10, C-12, C-15, C-16
1868387
BRACKET
R2900
R2900
9EL3985
BRACKET
R2900
R2900
2424357
BRACKET
R2900
R2900
9EL4287
BRACKET
R2900
R2900
9EL5703
BRACKET
R2900
R2900
9EL5262
BRACKET
R2900
R2900
9EL3617
BRACKET
R2900
R2900
3141906
BRACKET
R2900
R2900
7N7916
BRACKET
3406, 3406B, 3406C, 3406E, C-15, HT400
3406, 3406B, 3406C, 3406E, C-15, HT400
6N2283
BRACKET
3406, 3406B, 3406C, 3406E, 3456, 375, 375 L, 5080, 613C II, 613G, 621G, 623G, 627G, 657B, 814F, 815B, 815F, 816F, 916, 918F, 926, 938F, 966D, 966F, 966F II, 966G, 970F, 972G, C15, C18, CX31-C18I, CX35...
3406, 3406B, 3406C, 3406E, 3456, 375, 375 L, 5080, 613C II, 613G, 621G, 623G, 627G, 657B, 814F, 815B, 815F, 816F, 916, 918F, 926, 938F, 966D, 966F, 966F II, 966G, 970F, 972G, C15, C18, CX31-C18I, CX35...
4N5264
BRACKET AS
16G, 245, 245B, 3406, 3406B, 3406C, 3406E, 375, 621B, 623B, 627B, 735, 740, 983B, G3406, PM-465, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
16G, 245, 245B, 3406, 3406B, 3406C, 3406E, 375, 621B, 623B, 627B, 735, 740, 983B, G3406, PM-465, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
4N6162
BRACKET
245, 3406, 3406B, 3406C, 3406E, 375, 375 L, 5080, 561D, 735, 740, D8L, D9L, G3406, PM-465, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
245, 3406, 3406B, 3406C, 3406E, 375, 375 L, 5080, 561D, 735, 740, D8L, D9L, G3406, PM-465, RM-250C, RM-350B, RR-250, RR-250B, SM-350, SS-250
9Y4383
BRACKET-SHAFT
16G, 16H NA, 245B, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 814B, 824C, 824G, 825G, 826C, 826G, 980C, 980F, 980G, D350E, D400E, D8N, D8R, D8R II...
16G, 16H NA, 245B, 3406, 3406B, 3406C, 375, 375 L, 5080, 578, 583R, 587R, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 814B, 824C, 824G, 825G, 826C, 826G, 980C, 980F, 980G, D350E, D400E, D8N, D8R, D8R II...
4P9202
BRACKET
3406B, 3406C, D350E, D400E, G3406, HT400, PM-465, RM-250C, RR-250, RR-250B, SS-250
3406B, 3406C, D350E, D400E, G3406, HT400, PM-465, RM-250C, RR-250, RR-250B, SS-250
3T9331
BRACKET AS
3406B, 3406C, 950F II, D10N, D9L
3406B, 3406C, 950F II, D10N, D9L
4W0304
BRACKET
3406B, 3406C
3406B, 3406C
7C5404
BRACKET
3406B, 3406C
3406B, 3406C
5N6501
BRACKET
3406B, 3406C, 3408, 3408C, 3412, 3412C
3406B, 3406C, 3408, 3408C, 3412, 3412C
7N9863
BRACKET
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406
7N9864
BRACKET
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406