7Y1811 BRACKET Caterpillar parts
311, 311B, 312, 315, 317, 320 L, 325, 325D, OEMS  
 
 
Rating:
 Alternative (cross code) number:
CA7Y1811
7Y-1811
7Y1811
 
CA7Y1811
7Y-1811
7Y1811
 
 
  Weight: 14 pounds 6 kg. 
  EXCAVATOR, UNDERCARRIAGE,
Compatible equipment models: 7Y1811:
Information:
 Which Generate This Code:The FMI 13 is associated with the PWM thumb wheel on the left joystick or the PWM thumb wheel on the right joystick. The FMI 13 means that the ECM has determined that the signal of the PWM thumb wheel is not within expected limits. The possible causes of this diagnostic code are listed:
The PWM thumb wheel needs to be calibrated.
The PWM thumb wheel needs to be adjusted.
The ECM has been flashed with new software.
The PWM thumb wheel has failed.
The ECM has failed.Note: Other diagnostic codes for the switches on the joystick may occur if the machine configuration is not correct for the installed joysticks. Ensure that the machine configuration is correct.Note: Ensure that you have repaired any condition that would cause other active diagnostic codes that are related to the thumb wheel. For example, the CID 1132 FMI 03 or FMI 04 are not active when the CID 1132 FMI 13 is active. If the other diagnostic codes are active, troubleshoot those codes first. Then perform this procedure.Note: Ensure that the diagnostic code of CID 1132 FMI 13 is active before performing this procedure.Test Step 1. CHECK THE CALIBRATION
Perform the necessary adjustment and calibration procedures. Refer to the Testing and Adjusting section of the Service Manual for these procedures.
Observe the status of the CID 1132 FMI 13.Expected Result:The CID 1132 FMI 13 is not active.Results:
OK - The CID 1132 FMI 13 is not active. The calibration corrected the condition that caused the CID 1132 FMI 13. Resume normal operation. Stop.
NOT OK - The CID 1132 FMI 13 is still active.Repair: The diagnostic code is still active. Verify that the correct software has been flashed into the ECM, or that the correct ECM is installed on the machine. Then repeat the calibration. If the diagnostic code is still active and the cause of the diagnostic code is not found replace the ECM. It is unlikely that the ECM has failed. Verify that the thumb wheel and associated circuits are correct before you replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
 The PWM thumb wheel needs to be calibrated.
The PWM thumb wheel needs to be adjusted.
The ECM has been flashed with new software.
The PWM thumb wheel has failed.
The ECM has failed.Note: Other diagnostic codes for the switches on the joystick may occur if the machine configuration is not correct for the installed joysticks. Ensure that the machine configuration is correct.Note: Ensure that you have repaired any condition that would cause other active diagnostic codes that are related to the thumb wheel. For example, the CID 1132 FMI 03 or FMI 04 are not active when the CID 1132 FMI 13 is active. If the other diagnostic codes are active, troubleshoot those codes first. Then perform this procedure.Note: Ensure that the diagnostic code of CID 1132 FMI 13 is active before performing this procedure.Test Step 1. CHECK THE CALIBRATION
Perform the necessary adjustment and calibration procedures. Refer to the Testing and Adjusting section of the Service Manual for these procedures.
Observe the status of the CID 1132 FMI 13.Expected Result:The CID 1132 FMI 13 is not active.Results:
OK - The CID 1132 FMI 13 is not active. The calibration corrected the condition that caused the CID 1132 FMI 13. Resume normal operation. Stop.
NOT OK - The CID 1132 FMI 13 is still active.Repair: The diagnostic code is still active. Verify that the correct software has been flashed into the ECM, or that the correct ECM is installed on the machine. Then repeat the calibration. If the diagnostic code is still active and the cause of the diagnostic code is not found replace the ECM. It is unlikely that the ECM has failed. Verify that the thumb wheel and associated circuits are correct before you replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
Caterpillar parts catalog:
Parts bracket Caterpillar catalog:
 7C8366
BRACKET AS
 
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 214B, 224B, 3114, 3116, 3126, 3126B, 3...
 
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 214B, 224B, 3114, 3116, 3126, 3126B, 3...
 6I1206
BRACKET-SHAFT
 
212, 3054, 3054B, 3056, 3056E, 307, 312, 312B L, 312C, 315, 315B L, 317, 416B, 416C, 416D, 420D, 424D, 426B, 426C, 428B, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 550B, 554, 560B, 564, 574B, 908...
 
212, 3054, 3054B, 3056, 3056E, 307, 312, 312B L, 312C, 315, 315B L, 317, 416B, 416C, 416D, 420D, 424D, 426B, 426C, 428B, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 550B, 554, 560B, 564, 574B, 908...
 7C1281
BRACKET
 
120M, 12M, 2470C, 3054, 3054B, 3054C, 3054E, 3056, 3056E, 307, 312, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 315, 315B L, 315C, 317, 318D2 L, 320D GC, 320D L, 320D2, 320D2 L, 323D L, 414E, 416B, 41...
 
120M, 12M, 2470C, 3054, 3054B, 3054C, 3054E, 3056, 3056E, 307, 312, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 315, 315B L, 315C, 317, 318D2 L, 320D GC, 320D L, 320D2, 320D2 L, 323D L, 414E, 416B, 41...
 3A9071
BRACKET
 
312, 312B L
 
312, 312B L
 3A9077
BRACKET
 
312
 
312
 1396003
BRACKET
 
312, 312B L, 312C, 315B L, 315C, 317B LN, 318B, 318C, 319C
 
312, 312B L, 312C, 315B L, 315C, 317B LN, 318B, 318C, 319C
 5I8156
BRACKET
 
315, 315B, 315C, 317B LN, 318B
 
315, 315B, 315C, 317B LN, 318B
 4I3078
BRACKET-STOPPER
 
307, 307B, 311, 311B, 315, 318B, 320 L, 320B, 320N, 322 FM L, 325, 325 L, 325 LN, 325B, 330, 330 FM L, 330 L, 345B II, 350, 365B, 365B L, 385B
 
307, 307B, 311, 311B, 315, 318B, 320 L, 320B, 320N, 322 FM L, 325, 325 L, 325 LN, 325B, 330, 330 FM L, 330 L, 345B II, 350, 365B, 365B L, 385B
 5I7722
BRACKET
 
311, 311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 320N, 321C, 323D L, 323D LN
 
311, 311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 320N, 321C, 323D L, 323D LN
 1653065
BRACKET-MIRROR
 
312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320...
 
312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320...
 5I7850
BRACKET
 
311, 311B, 312B
 
311, 311B, 312B
 6I6444
BRACKET
 
311
  
311
 5I8273
BRACKET
 
307, 311, 311B, 312, 312B, 312B L, 312C, 313B, 315, 315B, 315B L, 317, 317B LN, 318B, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320C L, 320D LRR, 320D RR, 320N, 321B, 321C, 322, 322 FM L, 322 LN...
 
 
307, 311, 311B, 312, 312B, 312B L, 312C, 313B, 315, 315B, 315B L, 317, 317B LN, 318B, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320C L, 320D LRR, 320D RR, 320N, 321B, 321C, 322, 322 FM L, 322 LN...
 1311754
BRACKET AS
 
307, 63
 
307, 63
 1140235
BRACKET
 
307
 
307
 1093543
BRACKET
 
307, 312, 312B L, 315, 317
 
307, 312, 312B L, 315, 317
 6W5997
BRACKET
 
215C, 215D, 225, 225D, 227, 229
  
215C, 215D, 225, 225D, 227, 229
 1255651
BRACKET AS
 
315, 317
 
315, 317
 1335450
BRACKET AS
 
312, 315
 
312, 315
 1341275
BRACKET AS
 
312, 315
 
312, 315
 1219950
BRACKET AS
 
312, 63
 
312, 63
 1255650
BRACKET AS
 
115, 312, 315, 317, H140CS, H140DS
 
115, 312, 315, 317, H140CS, H140DS
 1265717
BRACKET
 
312, 315, 317
 
312, 315, 317
 
 
 
 
 
 
 
 
 
 
 
 