9Y0960 BREAKER AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA9Y0960
9Y-0960
9Y0960
CA9Y0960
9Y-0960
9Y0960
Weight: 8 pounds 3 kg.
Information:
65C (2ZJ),
Challenger 65D (2ZJ),
Challenger 70C (2YL),
Challenger 75C (4KK),
Challenger 75D (5AR),
Challenger 85C (9TK),
Challenger 85D (4GR) Agricultural TractorsReference: Service Manual Module; SENR8475; System Operation Testing & Adjusting; Hydraulic System; Challenger 65D, Challenger 75C, and Challenger 85C Agricultural Tractors.Service Manual Module; SENR9441; System Operation Testing & Adjusting; Hydraulic System; Challenger 65D, Challenger 75D, and Challenger 85D Agricultural Tractors.
Service Manual Module; SENR5265; System Operation Testing & Adjusting; Hydraulic System; Challenger 65C, Challenger 70C, Challenger 75C, and Challenger 85C Agricultural Tractors.
The implement valve detent kickout pressure testing and adjusting specifications have been changed.
Before checking the detent kickout pressure, make sure the oil temperature is near 49°C (120°F). When setting individual section detent kickouts, check the detent kickout pressure by using the signal (load sense) line rather than the work port pressure.
The actual detent kickout pressure setting and tolerance is changed from 15500 340 kPa (2250 50 psi) to 15850 1030 kPa (2300 150 psi). This allows additional flexibility in adjustment of detents for implements running at higher pressures, and accounts for the variations in kickout pressures due to temperature and pressure rise rates.
Challenger 65D (2ZJ),
Challenger 70C (2YL),
Challenger 75C (4KK),
Challenger 75D (5AR),
Challenger 85C (9TK),
Challenger 85D (4GR) Agricultural TractorsReference: Service Manual Module; SENR8475; System Operation Testing & Adjusting; Hydraulic System; Challenger 65D, Challenger 75C, and Challenger 85C Agricultural Tractors.Service Manual Module; SENR9441; System Operation Testing & Adjusting; Hydraulic System; Challenger 65D, Challenger 75D, and Challenger 85D Agricultural Tractors.
Service Manual Module; SENR5265; System Operation Testing & Adjusting; Hydraulic System; Challenger 65C, Challenger 70C, Challenger 75C, and Challenger 85C Agricultural Tractors.
The implement valve detent kickout pressure testing and adjusting specifications have been changed.
Before checking the detent kickout pressure, make sure the oil temperature is near 49°C (120°F). When setting individual section detent kickouts, check the detent kickout pressure by using the signal (load sense) line rather than the work port pressure.
The actual detent kickout pressure setting and tolerance is changed from 15500 340 kPa (2250 50 psi) to 15850 1030 kPa (2300 150 psi). This allows additional flexibility in adjustment of detents for implements running at higher pressures, and accounts for the variations in kickout pressures due to temperature and pressure rise rates.
Parts breaker Caterpillar catalog:
9Y0959
BREAKER AS
Caterpillar
Caterpillar
9Y0958
BREAKER AS
Caterpillar
Caterpillar
9Y0957
BREAKER AS
Caterpillar
Caterpillar
9Y0956
BREAKER AS
Caterpillar
Caterpillar
9Y0955
BREAKER AS
Caterpillar
Caterpillar
9Y0954
BREAKER AS
Caterpillar
Caterpillar
9Y2833
BREAKER AS
Caterpillar
Caterpillar
9Y0981
BREAKER AS
Caterpillar
Caterpillar
9Y0980
BREAKER AS
Caterpillar
Caterpillar
9Y0979
BREAKER AS
Caterpillar
Caterpillar
9Y0962
BREAKER AS
Caterpillar
Caterpillar
9Y0961
BREAKER AS
Caterpillar
Caterpillar