Information:
Illustration 1 g01758805
Reverse clutch solenoid connections
Illustration 2 g01891554
Location of the reverse clutch solenoidThis diagnostic code is associated with the reverse clutch solenoid. The FMI 05 means the ECM has determined that an open exists in the circuit for the solenoid.The possible causes of this diagnostic code are listed below:
There energize circuit of the solenoid is open
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely.Note: The following procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Ensure that the diagnostic code of CID 1401 FMI 05 is active before performing this procedure.System Response:When this code is active, the implement lockout solenoid is deactivated (LOCKED) unless the limp home mode is selected. All implement functions are disabled. Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. DO NOT start the engine.
Disconnect the reverse clutch solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 752-YL) to contact 2 (wire 975-WH).
Observe the status of the CID 1401 FMI 05.Expected Result:The active diagnostic code changes from an FMI "05" to an FMI "06" diagnostic code as the jumper wire is installed.Results:
YES - The active diagnostic code changes from an FMI "05" to an FMI "06" diagnostic code when the jumper wire is installed. The solenoid has failed.Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify that the solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem. STOP
NO - The CID 1401 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2Test Step 2. CHECK THE HARNESS FOR AN OPEN
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the ECM.
The jumper wire that was installed in the previous test step remains in place.
At the machine harness connector, measure the resistance from signal contact J1-65 (wire 752-YL) to J1-55 (wire 975-WH). Expected Result:The resistance should be less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5.0 ohms. The resistance measurement is not correct.Repair: A resistance measurement that is much greater than 5 ohms but less than 5000 ohms could indicate that one of the connection points in the circuit is not open but is not a good connection.There is an open circuit or a bad connection in the machine harness. The problem is in signal wire 752-YL or in the return 975-WH of the machine harness. Refer to the complete machine Electrical System Schematic and check all harness connectors that are in this circuit. Ensure that all connector contacts are clean, tight and in good condition. Repair the
Caterpillar parts catalog:
Parts bushing Caterpillar catalog:
1K4691
BUSHING
561B, 988
561B, 988
2M8901
BUSHING
D8H
D8H
2J2130
BUSHING
172
172
6F5072
BUSHING
955H
955H
1H5223
BUSHING
955H
955H
9M0841
BUSHING
16, 651
16, 651
4K1306
BUSHING
955H
955H
3J4823
BUSHING
184, 46
184, 46
4J8716
BUSHING
129
129
4K7668
BUSHING
955H
955H