2S0253 BUSHING Caterpillar parts
365B, 365B L, 375, 375 L, 5080, 594, 594H, D9E, D9G, D9H
Rating:
Alternative (cross code) number:
CA2S0253
2S-0253
2S0253
CA2S0253
2S-0253
2S0253
Weight: 12 pounds 5 kg.
EXCAVATOR, TRACK-TYPE TRACTOR,
Compatible equipment models: 2S0253:
Information:
Set up for Multi-unit Paralleling
For island paralleling mode, all units must be interconnected with control wiring for proper load sharing and control functions. All connections are made in the customer connection box.Review what type of control system is used in each unit that will be paralleled together. Reviewing the control system is the first step in determining how to interconnect units.Using 24 Pin Interconnect Harness
Install the factory-supplied 24 pin interconnect harness beginning at connector B (lower) on the first unit to connector A (upper) of the next unit. Continue in this fashion until all Units are connected together. No other interconnect control wiring is required.Dead bus arbitration - When starting the group of units, the first unit up to rated voltage and frequency will close to the dead bus. Remaining units synchronize to the live bus.Load sense/load demand - Automatically regulates which units to be running and paralleled on the common bus based on the load level. Higher load levels will require more units to run, lower load levels will require fewer units to run. To use this feature, each unit must be configured uniquely. Refer to Special Instruction, LEBE0007, "EMCP 4.4 Application and Installation Guide". This feature is disabled as factory default.Group start - Allows for starting the entire group of units by wiring the remote start contact to a single unit within the group. In order to use this feature, connect a remote run request contact to terminals GRR+ and GRR- on any one unit.Real power (kW) sharing - Automatically shares the load (kW) proportionally among all paralleled units.Reactive power (kVAr) sharing - Automatically shares reactive load (VAr) proportionally among all paralleled units. Uses a 0-10V analog signal which is not designed to interface to any devices other than EMCP 4.4.Manual Operation
The power module can be used in parallel with other units to provide power for an isolated load. Manual operation refers to manually closing the generator breaker using the circuit breaker switch. The following information describes the steps for manual operation.
Ensure that all load cable connections have been correctly made.
Verify that the unit can be safely started.
Verify that power can be applied to the load.Start Up Procedure for the First Unit
The following procedure applies to the first or primary unit that will be closing to a dead bus.
Press the "RUN" button that is on the EMCP 4.4.Note: The engine will begin to start immediately.
Use the EMCP 4.4 display to observe the generator voltage and the frequency once the engine is running at the rated speed.Note: The sync mode setting in the EMCP 4.4 will automatically change to "Check" mode when the EMCP 4.4 powers up. Additionally, the sync mode setting will automatically change to "Check" mode whenever the EMCP 4.4 "STOP" button is pressed. "Check"mode causes automatic generator-to-bus synchronization (not applicable in "Single Unit Mode") but requires manual closing of the generator breaker using the circuit breaker switch.Note: If the manual voltage and/or frequency adjustment (prior to breaker closing) is desired, then change the EMCP
For island paralleling mode, all units must be interconnected with control wiring for proper load sharing and control functions. All connections are made in the customer connection box.Review what type of control system is used in each unit that will be paralleled together. Reviewing the control system is the first step in determining how to interconnect units.Using 24 Pin Interconnect Harness
Install the factory-supplied 24 pin interconnect harness beginning at connector B (lower) on the first unit to connector A (upper) of the next unit. Continue in this fashion until all Units are connected together. No other interconnect control wiring is required.Dead bus arbitration - When starting the group of units, the first unit up to rated voltage and frequency will close to the dead bus. Remaining units synchronize to the live bus.Load sense/load demand - Automatically regulates which units to be running and paralleled on the common bus based on the load level. Higher load levels will require more units to run, lower load levels will require fewer units to run. To use this feature, each unit must be configured uniquely. Refer to Special Instruction, LEBE0007, "EMCP 4.4 Application and Installation Guide". This feature is disabled as factory default.Group start - Allows for starting the entire group of units by wiring the remote start contact to a single unit within the group. In order to use this feature, connect a remote run request contact to terminals GRR+ and GRR- on any one unit.Real power (kW) sharing - Automatically shares the load (kW) proportionally among all paralleled units.Reactive power (kVAr) sharing - Automatically shares reactive load (VAr) proportionally among all paralleled units. Uses a 0-10V analog signal which is not designed to interface to any devices other than EMCP 4.4.Manual Operation
The power module can be used in parallel with other units to provide power for an isolated load. Manual operation refers to manually closing the generator breaker using the circuit breaker switch. The following information describes the steps for manual operation.
Ensure that all load cable connections have been correctly made.
Verify that the unit can be safely started.
Verify that power can be applied to the load.Start Up Procedure for the First Unit
The following procedure applies to the first or primary unit that will be closing to a dead bus.
Press the "RUN" button that is on the EMCP 4.4.Note: The engine will begin to start immediately.
Use the EMCP 4.4 display to observe the generator voltage and the frequency once the engine is running at the rated speed.Note: The sync mode setting in the EMCP 4.4 will automatically change to "Check" mode when the EMCP 4.4 powers up. Additionally, the sync mode setting will automatically change to "Check" mode whenever the EMCP 4.4 "STOP" button is pressed. "Check"mode causes automatic generator-to-bus synchronization (not applicable in "Single Unit Mode") but requires manual closing of the generator breaker using the circuit breaker switch.Note: If the manual voltage and/or frequency adjustment (prior to breaker closing) is desired, then change the EMCP
Cat SIS web machinery list:
Parts bushing Caterpillar catalog:
1140757
BUSHING
1390, 2590, 320 L, 320B, 320C, 320D, 320D FM, 320D2, 320D2 L, 322 LN, 322B L, 322B LN, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E LN, 325B L, 325C, 325C ...
1390, 2590, 320 L, 320B, 320C, 320D, 320D FM, 320D2, 320D2 L, 322 LN, 322B L, 322B LN, 322C, 322C FM, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 324E LN, 325B L, 325C, 325C ...
9T8511
BUSHING
350, 365B, 365B II, 365B L, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 5080, 5090B, M322C, M322D, M322D MH
350, 365B, 365B II, 365B L, 365C, 365C L, 375, 375 L, 385B, 385C, 385C FS, 385C L, 5080, 5090B, M322C, M322D, M322D MH
7Y4254
BUSHING-TERMINAL
322, 322 FM L, 322 LN, 322B L, 322B LN, 325, 325 L, 325 LN, 325B, 325B L, 330, 330 FM L, 330 L, 330B, 330B L, 350, 375, 375 L, 5080, E240C, E300B, EL240B, M325B, TK1051, W330B
322, 322 FM L, 322 LN, 322B L, 322B LN, 325, 325 L, 325 LN, 325B, 325B L, 330, 330 FM L, 330 L, 330B, 330B L, 350, 375, 375 L, 5080, E240C, E300B, EL240B, M325B, TK1051, W330B
1588967
BUSHING
365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5090B
365B, 365B II, 365B L, 365C, 365C L, 365C L MH, 374D L, 374F L, 385B, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 390F L, 5090B
1035348
BUSHING
325 L, 325B L, 325C, 325C FM, 325D FM, 325D FM LL, 325D MH, 330, 330 FM L, 330 L, 330B, 330B L, 330C FM, 330D FM, 350, 350 L, 375, 568 FM LL, M325B, M330D
325 L, 325B L, 325C, 325C FM, 325D FM, 325D FM LL, 325D MH, 330, 330 FM L, 330 L, 330B, 330B L, 330C FM, 330D FM, 350, 350 L, 375, 568 FM LL, M325B, M330D
0875379
BUSHING
24H, 24M, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330D FM, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, ...
24H, 24M, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330D FM, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, ...
4I6897
BUSHING
324D, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E L, 336E LN, 336F L, 340D L, 340D2 L, 345B II, 345B II MH, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 34...
324D, 330D, 330D L, 330D LN, 336D, 336D L, 336D LN, 336D2, 336D2 L, 336E, 336E L, 336E LN, 336F L, 340D L, 340D2 L, 345B II, 345B II MH, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 34...
4I6718
BUSHING
345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, 365C, 365C L, 374D L, 374F L, 385C, P115, VPC-30
345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, 365C, 365C L, 374D L, 374F L, 385C, P115, VPC-30
1531728
BUSHING
365B, 365B II, 365B L, 365C, 385B, S365B, S365C, S465, VHS-60/3
365B, 365B II, 365B L, 365C, 385B, S365B, S365C, S465, VHS-60/3
4I1520
BUSHING
345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, 365C, 365C L, 374D L, 374F L, 385C
345B II, 345B L, 345C, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 350, 365B, 365B II, 365B L, 365C, 365C L, 374D L, 374F L, 385C
2285622
BUSHING
345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 365B L, 385B, W345C MH
345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L VG, 349F L, 365B L, 385B, W345C MH
1510650
BUSHING
345B II, 345B II MH, 345B L, 345C, 365B, W345B II
345B II, 345B II MH, 345B L, 345C, 365B, W345B II
3H6842
BUSHING
D9G
D9G
5M2608
BUSHING ASSEM.
594, D9E, D9G, D9H
594, D9E, D9G, D9H
1S1607
BUSHING
594, 594H, 988
594, 594H, 988
1B2355
BUSHING
594H, 814, 966C, 977K, 977L, 983, D9G
594H, 814, 966C, 977K, 977L, 983, D9G
1H4561
BUSHING
D9E, D9G
D9E, D9G
2K1283
BUSHING
572G, 583H, 583K
572G, 583H, 583K
8S5801
BUSHING ASSEM.
561C, 951B, 953, 955H, 955K, 955L, D5, D5B
561C, 951B, 953, 955H, 955K, 955L, D5, D5B
8S5800
BUSHING ASSEM.
561C, 951B, D5B
561C, 951B, D5B
3J9785
BUSHING
10S, 621H, 621K, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 657E, 657G, 824S, 8A, 8S, 9A, D10, D8H, D9G, D9H, D9L
10S, 621H, 621K, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 657E, 657G, 824S, 8A, 8S, 9A, D10, D8H, D9G, D9H, D9L
2J5630
BUSHING
8A, 8S
8A, 8S
8S5344
BUSHING ASSEM.
D6C, D6D
D6C, D6D