3G5285 BUSHING Caterpillar parts
928G, 928HZ, 936, 936F, 938F, 938G, 938G II, 938H, 973D, G936, IT28G
Rating:
Alternative (cross code) number:
CA3G5285
3G-5285
3G5285
CA3G5285
3G-5285
3G5285
Weight: 1 pounds 0 kg.
Information:
ID
70.102
mm
OD
81.98
mm
WIDTH
63.5
mm
INTEGRATED TOOLCARRIER, WHEEL LOADER,
Related part:
3G5285
BEARING-SLV-YM
3602312
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$15.44
18 Oct 2021
Amazon.com
CTP 3G5285 Sleeve Bearing for Heavy Equipment
CTP Sleeve Bearing Only || Sold in each || Easy in-and-out fit
CTP Sleeve Bearing Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 3G5285:
Information:
Engine: C175-16 (S/N: P6L122-UP) C280-16 (S/N: NKB300-UP)Generator Set: C18 MARINE GS (S/N: GBM216-UP)Marine Engine: C32 MARINE (S/N: RNZ997-UP) C32 MARINE GS (S/N: RNF1-UP)Introduction
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, follow the action that is mentioned below.Problem
The engines and gensets equipped with an Auto-Maskin control panel can have the starter being engaged inadvertently due to failure of Digital Communication Unit (DCU) crank output in a high state when the DCU is shorted to battery or experiences a voltage spike from the starter motor mag switch.Solution
Install a 179-8829 Relay to protect the Digital Communication Unit (DCU) from overcurrent, and configure the DCU by using "Config Output 4" instead of Crank 1.Safety
Only persons with training in electrical installations must carry connections to the generator.The generator must be wired correctly. A fire or electrocution could result from wiring that is incorrect.The generator is capable of generating high voltages. Ensure that the generator is not on while the connections are being made. Follow these two steps in order to prevent accidental starting:
Isolate the DC breaker.
Disconnect the DC supply battery.
High voltage may be present. The power source must be disconnected before working on the equipment. Failure to disconnect the power source could result in injury or death. Verify that the equipment is not energized before performing any maintenance. This work must be performed by trained personnel with correct tools and procedures. Bodily contact with electrical potential will cause personal injury or death.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Procedure for Installing Relay
Perform the following procedure to install the 179-8829 Relay :
Illustration 1 g03325666
Rear of Auto-Maskin control panel (1) Digital Communication Unit (DCU) (2) Pins 83 and 77 (3) E-Stop (4) wire (T789-YL)
Illustration 2 g03325667
Inside of Auto-Maskin control panel (5) Place to install relay (6) DIN rail terminal 112 (7) DIN rail terminal 229
Remove the wire (T789-YL) (4) from pin-83 (2) of DCU (1) and pin-R11 of E-Stop (3) .
Illustration 3 g03325668
Install 179-8829 Relay and 179-8828 Relay Base at the top of DIN Rail. Refer to Illustration 3.
Illustration 4 g03325669
Connect the new wire (T789-YL) (4) from pin-77 (2) of DCU (1) to pin-8 of 179-8829 Relay .
Connect the wire from DIN Rail terminal 229 (7) to pin-1 of 179-8829 Relay .
Connect the wire from DIN Rail terminal 112 (6) to pin-2 of 179-8829 Relay .
Connect the wire from pin-3 of 179-8829 Relay to pin-R11 of E-Stop (3) .Procedure for Updating DCU
Perform the following procedure to configure the DCU:Procedure for Connecting a Laptop to DCU
Perform the following procedure for connecting a laptop to DCU:
Illustration 5 g03325672
(8) "Menu" button
Press the "Menu" button (8) from the DCU screen.Show/hide ta
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, follow the action that is mentioned below.Problem
The engines and gensets equipped with an Auto-Maskin control panel can have the starter being engaged inadvertently due to failure of Digital Communication Unit (DCU) crank output in a high state when the DCU is shorted to battery or experiences a voltage spike from the starter motor mag switch.Solution
Install a 179-8829 Relay to protect the Digital Communication Unit (DCU) from overcurrent, and configure the DCU by using "Config Output 4" instead of Crank 1.Safety
Only persons with training in electrical installations must carry connections to the generator.The generator must be wired correctly. A fire or electrocution could result from wiring that is incorrect.The generator is capable of generating high voltages. Ensure that the generator is not on while the connections are being made. Follow these two steps in order to prevent accidental starting:
Isolate the DC breaker.
Disconnect the DC supply battery.
High voltage may be present. The power source must be disconnected before working on the equipment. Failure to disconnect the power source could result in injury or death. Verify that the equipment is not energized before performing any maintenance. This work must be performed by trained personnel with correct tools and procedures. Bodily contact with electrical potential will cause personal injury or death.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Procedure for Installing Relay
Perform the following procedure to install the 179-8829 Relay :
Illustration 1 g03325666
Rear of Auto-Maskin control panel (1) Digital Communication Unit (DCU) (2) Pins 83 and 77 (3) E-Stop (4) wire (T789-YL)
Illustration 2 g03325667
Inside of Auto-Maskin control panel (5) Place to install relay (6) DIN rail terminal 112 (7) DIN rail terminal 229
Remove the wire (T789-YL) (4) from pin-83 (2) of DCU (1) and pin-R11 of E-Stop (3) .
Illustration 3 g03325668
Install 179-8829 Relay and 179-8828 Relay Base at the top of DIN Rail. Refer to Illustration 3.
Illustration 4 g03325669
Connect the new wire (T789-YL) (4) from pin-77 (2) of DCU (1) to pin-8 of 179-8829 Relay .
Connect the wire from DIN Rail terminal 229 (7) to pin-1 of 179-8829 Relay .
Connect the wire from DIN Rail terminal 112 (6) to pin-2 of 179-8829 Relay .
Connect the wire from pin-3 of 179-8829 Relay to pin-R11 of E-Stop (3) .Procedure for Updating DCU
Perform the following procedure to configure the DCU:Procedure for Connecting a Laptop to DCU
Perform the following procedure for connecting a laptop to DCU:
Illustration 5 g03325672
(8) "Menu" button
Press the "Menu" button (8) from the DCU screen.Show/hide ta
Caterpillar parts catalog:
Parts bushing Caterpillar catalog:
2131364
BUSHING
938F, 938G, 938G II, IT38F, IT38G, IT38G II
938F, 938G, 938G II, IT38F, IT38G, IT38G II
2131370
BUSHING
2470C, 2570C, 2670C, 2864C, 533, 543, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 938F, 938G, 938G II, 950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, 966G, 966G II, 966...
2470C, 2570C, 2670C, 2864C, 533, 543, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 938F, 938G, 938G II, 950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, 966G, 966G II, 966...
3G4704
BUSHING
533, 543, 545, 910K, 914K, 930K, 936, 936F, 938F, 938G, 938G II, 938H, 950B, 950F, 950F II, 960F, G936, HA770, HA771, HA870, HA871, HYDRAULIC, IT38F, IT38G, IT38G II, IT38H, TK370, TK371, TK380, TK381
533, 543, 545, 910K, 914K, 930K, 936, 936F, 938F, 938G, 938G II, 938H, 950B, 950F, 950F II, 960F, G936, HA770, HA771, HA870, HA871, HYDRAULIC, IT38F, IT38G, IT38G II, IT38H, TK370, TK371, TK380, TK381
4V2883
BUSHING
928G, 928HZ, 936, 936F, 938F, 938G, 938G II, 938H, 962G, G936, IT28G, IT38F, IT38G, IT38G II, IT38H, IT62G, IT62G II, IT62H
928G, 928HZ, 936, 936F, 938F, 938G, 938G II, 938H, 962G, G936, IT28G, IT38F, IT38G, IT38G II, IT38H, IT62G, IT62G II, IT62H
4V8629
BUSHING
824H, 826G, 826G II, 826H, 910E, 914G, 916, 928G, 928HZ, IT14G2, IT18, IT18B, IT28G
824H, 826G, 826G II, 826H, 910E, 914G, 916, 928G, 928HZ, IT14G2, IT18, IT18B, IT28G
1V9148
BUSHING
227, 928G, 928HZ, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, IT28G
227, 928G, 928HZ, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, IT28G
9G7683
BUSHING
936, 936F, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 950H, 950K, 960F, 962G, 962G II, 962H, 962K, 966C, 966H, 966K, 966M, 966R, G936, IT62G, IT62G II, IT62H, R1300, R1300G, R1300G II
936, 936F, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 950H, 950K, 960F, 962G, 962G II, 962H, 962K, 966C, 966H, 966K, 966M, 966R, G936, IT62G, IT62G II, IT62H, R1300, R1300G, R1300G II
4V4453
BUSHING
924G, 924GZ, 924H, 924HZ, 926, 926A, 928F, 928HZ, 930G, 938K
924G, 924GZ, 924H, 924HZ, 926, 926A, 928F, 928HZ, 930G, 938K
5V1007
BUSHING
936, 936F, 938G II, 938H, 938K, CS-643, G936, IT38G II, IT38H
936, 936F, 938G II, 938H, 938K, CS-643, G936, IT38G II, IT38H
7J9709
BUSHING
928HZ, 930G, 950K, 962K, 988
928HZ, 930G, 950K, 962K, 988
4V8520
BUSHING
928HZ, 930G, 950G II, 950H, 962G II, 962H, 966D, 966F, 966F II, 966G, 966G II, 966H, 966K, 966M, 966M XE, 970F, 972G, 972G II, 972H, 972K, 972M, 972M XE, 986H
928HZ, 930G, 950G II, 950H, 962G II, 962H, 966D, 966F, 966F II, 966G, 966G II, 966H, 966K, 966M, 966M XE, 970F, 972G, 972G II, 972H, 972K, 972M, 972M XE, 986H
1V8242
BUSHING
928HZ, 930G, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, 986H, R1300, R1300G, R1300G II
928HZ, 930G, 980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, 980M, 982M, 986H, R1300, R1300G, R1300G II
2377305
BUSHING-TRACK
D6G2 XL
D6G2 XL
3981067
BUSHING
D6T
D6T
2367540
BUSHING
D4K XL
D4K XL
2414939
BUSHING
814F, 815F, 816F, 824H, 825H, 826H, 834H, 836H, 844H, 854G, 924G, 924H, 924K, 928HZ, 930G, 930K, 938G II, 938H, 938K, 950 GC, 950H, 962H, 966H, 972H, 980H, 986H, 988H, 990H, 992G, 994F, D3K2 LGP, D4K2...
814F, 815F, 816F, 824H, 825H, 826H, 834H, 836H, 844H, 854G, 924G, 924H, 924K, 928HZ, 930G, 930K, 938G II, 938H, 938K, 950 GC, 950H, 962H, 966H, 972H, 980H, 986H, 988H, 990H, 992G, 994F, D3K2 LGP, D4K2...
4173768
BUSHING AS
D6N LGP
D6N LGP
1072280
BUSHING
578, 980C, D8N
578, 980C, D8N
3G5999
BUSHING
D7E, D7E LGP, D7H, D7R, D7R II, D7R XR, D8L, D8N, D8R, D8R II, D8T, D9N, D9R, D9T
D7E, D7E LGP, D7H, D7R, D7R II, D7R XR, D8L, D8N, D8R, D8R II, D8T, D9N, D9R, D9T
5A7844
BUSHING
D6C, D6D, D6G2 LGP
D6C, D6D, D6G2 LGP
6E0804
BUSHING
330B L, 844, 844H, 844K, 854G, 854K, 973D, 990, 990 II, 990H, 990K, 992G, 992K, GSH15-60, GSH22B, GSH9, HEX-WEDGE
330B L, 844, 844H, 844K, 854G, 854K, 973D, 990, 990 II, 990H, 990K, 992G, 992K, GSH15-60, GSH22B, GSH9, HEX-WEDGE